5.3 Open and closing time
The open and the closing time of the TSG Sinus Drive can be set via the parameter h7 and hb.
The values can be changed in 0.01 second increments. The default value can be assumed for both the input
and for the exit of the drive for a time of 0.50 seconds. However, this value must be controlled and must be
adapted according to local circumstances.
Tabelle 1 Screw for stroke adjustment:
adjusted stroke of
Max load
parameter h7
(Opening time of the
skate)
parameter hb
(Closing time of the
skate)
ca.60mm
2,3kg
53
46
ca.45mm
3,1kg
54
45
ca.30mm
4,6kg
55
45
ca.20mm
7,0kg
54
46
CAUTION:
The values must not be set greater than the time that is really needed to drive on and extend.
Otherwise it can cause failure of the drive!
NOTE:
If a value is changed and confirmed, the value is stored permanently, ie even after a power
failure, the changed value is available again.
NOTE:
For more information on parameter setting see also the manual door control unit TSG.
5.4 Time delay between door drive and TSG Sinus Drive
It is possible to set that in an open command from the elevator control system to the door control device TSG
first drive the TSG Sinus Drive apart and then ascends the door. For this purpose, the parameter hC can be
adjusted. The value can be varied in 0.01 second increments.
NOTE:
For more information on parameter setting see also the manual door control unit TSG.
Summary of Contents for TSG Sinus Drive
Page 1: ...1 27 Installation Instruction TSG Sinus Drive on TSG V4...
Page 11: ...11 27...
Page 15: ...15 27 7 Illustration Abb 6 TSG Sinus Drive with bracket Abb 7 TSG Sinus Drive with roller...
Page 16: ...16 27 Abb 8 TSG electronics with expansion board for controlling TSG Sinus Drive...
Page 22: ...22 27 Abb 11 TSG Sinus Drive in Haushahn TSS72...
Page 23: ...23 27 Abb 12 TSG Sinus Drive in Prisma Concord...
Page 24: ...24 27 Abb 13 TSG Sinus Drive from behind Abb 14 TSG Sinus Drive from the front...
Page 25: ...25 27 Abb 15 TSG Sinus Drive with curve or roller Abb 16 Possibility to change the distance...
Page 26: ...26 27 Abb 17 Reinforcement for stabilization Abb 18 Reinforcement for stabilization...