OPERATION
Control Panel
NOTE: Cooking appliances must
be operated in accordance with the
manufacturer’s instructions.
During normal operation, the illuminated
power switch will be the only light on the
control panel that will be ON.
If the CHECK FILTERS light illuminates,
check BAFFLE FILTERS, PREFILTERS,
and the HEPA AIR FILTERS for proper
installation.
If the REPLACE PRE-FILTERS light
illuminates .. Replace the Pre-filters.
If the REPLACE FILTER light
illuminates, replace the FILTER PACK.
NOTE: the REPLACE FILTERS light is
a warning that filter pack is nearing the
end of its service life. The ventilator will
continue to operate for a period of time
after the REPLACE FILTER LIGHT turns
ON to allow continued operation through
a peak period. However, filter pack must
be replaced within a short time period or
it will clog, disabling the ventilator and
appliances.
If the SERVICE REQUIRED light
illuminates, the filter pack is restricted to
the point of insufficient airflow for proper
operation and the Ventilator will shut
down until the underlying clogged filter situation has been corrected.
Replace clogged item with a fresh filter to correct the condition.
Reset the unit by turning VENTILATOR POWER SWITCH to OFF,
then back to ON.
A failure of incoming electric power will cause a shut down of the unit.
Reset the unit by turning VENTILATOR POWER SWITCH to OFF, then
back to ON.
Operation Lights
There are two equipment lights that provide illumination of the working
area. These lights are controllled by the main power switch.
CAUTION:
HOT SURFACE
Exposed surfaces can be hot
to the touch and may cause
burns.
CAUTION:
SHOCK HAZARD
DO NOT splash or pour water
or grease onto control panel
or wiring.
IMPORTANT:
The ventilator cannot operate
if the filter pack is removed or
clogged.
It is the responsibility of
the store management to
maintain sufficient spares
of filter packs to avoid
prolonged shutdown of the
ventilator when this filter is
expended.
Filter packs cannot be
cleaned.
Lang Manufacturing assumes
no liability for loss of business
due to filter related shutdown.
Filters that are not genuine
Lang Replacement Parts may
cause your unit to operate
incorrectly and you will risk
the possibility of voiding your
warranty.
SERVICE
REQUIRED
REPLACE
FILTER PACK
REPLACE
PREFILTER
CHECK
FILTER
ON
POWER
OFF
IL2870