NSTALLATION

 

NOTICE 

These installation procedures must be followed by qualified personnel or warranty will be void. 

Local codes regarding installation vary greatly from one area to another. The National Fire Protection Association, 
Inc.  states  in  its  NFPA  96  latest  edition  that  local  codes  are  the  “authority  having  jurisdiction”  when  it  comes  to 
installation requirements for equipment. Therefore, installations must comply with all local codes, or in the absence 
of local codes, with the 

National Fuel Gas Code, ANSI Z223.1, Natural Gas Installation Code, CAN/CGA-B149.1, 

or the

 Propane Installation Code CAN/CGA-B149.2,

 as applicable, including: 

1. The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during 
any pressure testing of that system at test pressures in excess of 1/2 psi (3.45 kPa). 

2. The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve 
during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psi (3.45 
kPa). 

 

NOTICE 

EXHAUST  FANS  AND  CANOPIES:

  It  is  recommended  that  the  range  be  installed  under  a  ventilation  hood. 

Consult local codes for proper installation of hoods. Proper ventilation  is the owner’s responsibility. Any problem 
due to improper ventilation will not be covered by warranty. 

 

NOTICE 

In  the  Commonwealth  of  Massachusetts  all  gas  appliances  vented  by  either  mechanical  systems  or  ventilation 
hoods shall comply with 248 CMR interlocking requirements. 

 

S

TEP 

1:

 

U

NPACKING

 

IMMEDIATELY INSPECT FOR SHIPPING DAMAGE 

All  containers  should  be  examined  for  damage  before  and  during  unloading.  The  freight  carrier  has  assumed 
responsibility for its safe transit and delivery. If damaged equipment is received, either apparent or concealed, a 
claim must be made with the delivering carrier. 

Apparent  damage  or  loss  must  be  noted  on  the  freight  bill  at  the  time  of  delivery.  The  freight  bill  must  then  be 
signed by the carrier representative (Driver). If the bill is not signed, the carrier may refuse the claim. The carrier 
can supply the necessary forms. 

A request for inspection must be made to the carrier within 15 days if there is concealed damage or loss that is not 
apparent  until  after  the  equipment  is  uncrated.  The  carrier  should  arrange  an  inspection.  Be  certain  to  hold  all 
contents plus all packing material. 

 

1.  Cut the banding straps and remove the corrugated cardboard surrounding the broiler. Do not remove any of the 

attached tags or labels until the broiler is installed and working properly. 

2.  Cut the banding strap holding the broiler to the wooden skid. 

3.  If installing Infrared Compact Broiler which mounts over a range, go to Step 2a. 

If installing Infrared Compact Broiler which mounts on a wall, go to Step 2b. 
If installing Infrared Compact Broiler which has legs for countertop use, go to Step 2c. 

 

Summary of Contents for LGR36-NFR

Page 1: ...Read installation operation and maintenance instructions thoroughly before installing or servicing this equipment 10 Sunnen Drive St Louis MO 63143 USA www langworld com LGR36 NFR LGR36 RAD LGR48 NFR LGR48 RAD IMPORTANT FOR FUTURE REFERENCE Please complete this information and retain this manual for the life of the equipment Model __________________________ Serial __________________________ Date P...

Page 2: ...und cooking appliances free and clear of combustibles Purchaser of equipment must post in a prominent location detailed instructions to be followed in the event the operator smells gas Obtain the instructions from the local gas supplier WARNING BURN HAZARD Contact with hot surfaces will cause severe burns Always use caution when operating cooking appliances WARNING EXPLOSION AND ASPHYXIATION HAZAR...

Page 3: ... wall or used as a countertop unit by attaching legs to the base The serial plate is located under the broiler bottom grease drawer at the front toward the left see Figure 1 below Read these instructions carefully before attempting installation Installation and initial startup should be performed by a qualified installer Unless the installation instructions for this product are followed by a quali...

Page 4: ...revisions do not entitle the buyer to corresponding changes additions or replacements for previously purchased equipment This product is intended for commercial use only not for household use CLEARANCES There must be adequate clearance between the broiler and adjacent construction due to the heat generated by the broiler Clearance must also be provided for servicing and for operation The minimum c...

Page 5: ...COMPACT BROILER SPECIFICATIONS OWNER S MANUAL 1192039 10 09 PAGE 5 OF 24 DIMENSIONS Figure 2 Model Width W Height H Depth D LGR36 NFR LGR36 RAD 36 915 21 533 15 5 394 LGR48 NFR LGR48 RAD 48 1220 21 533 15 5 394 ...

Page 6: ...ck on and let it run to remove any exhaust that may have accumulated during the test GAS SUPPLY The broiler is design certified for operation on natural or propane gases The broiler is shipped configured and adjusted for the type of gas specified by the purchaser which is indicated on the serial plate see Figure 1 on page 3 Connect the broiler ONLY to the type of gas for which it is configured and...

Page 7: ...nergy is wasted in heating secondary surfaces which is necessary for conventional type broilers Since the surface of the ceramic tiles becomes red hot in less than one half minute the broiler is ready to start broiling with a very short preheat time thereby saving time labor and energy These glowing surfaces emit intense infrared rays which are transmitted directly onto the product thereby yieldin...

Page 8: ...dull red and the flame will have a blue haze color If the flame flutters or pops the broiler requires adjustment by a service technician 4 If searing the food to mark it with grid marks is desired before placing food on the grid move the broiler rack to its highest position and allow the burners to operate on HIGH for five minutes 5 Turn the burner control to HIGH or LOW as appropriate for the foo...

Page 9: ...he daily cleaning procedure is as follows 1 Turn all controls to OFF shut off the gas supply and allow time for the broiler to cool 2 Move the broiling rack to the low position Pull out the rolling broiler rack 3 Lift out the broiler grids and clean them with a wire brush or non toxic solvent 4 Lift out the 2 drip shields and clean them with soap and water 5 With rolling rack pulled out to its sto...

Page 10: ...ring pads or STAINLESS scouring pads DO NOT USE ORDINARY STEEL WOOL as any particles left on the surface will rust and further spoil the appearance of the finish NEVER USE A WIRE BRUSH STEEL SCOURING PADS EXCEPT STAINLESS SCRAPER FILE OR OTHER STEEL TOOLS Surfaces which are marred collect dirt more rapidly and become more difficult to clean Marring also increases the possibility of corrosive attac...

Page 11: ...to improper ventilation will not be covered by warranty NOTICE In the Commonwealth of Massachusetts all gas appliances vented by either mechanical systems or ventilation hoods shall comply with 248 CMR interlocking requirements STEP 1 UNPACKING IMMEDIATELY INSPECT FOR SHIPPING DAMAGE All containers should be examined for damage before and during unloading The freight carrier has assumed responsibi...

Page 12: ...f necessary move the broiler left or right so that the holes in the top of the broiler hook line up with the holes in the top of the flue riser then secure the broiler hook to the flue riser using three 10 self tapping screws provided 3 Secure the bottom of the broiler to the flue riser with the four self tapping screws provided The holes are accessible from the rear of the unit behind the wall sh...

Page 13: ...nfrared Compact Broiler 3 It may be more convenient to prepare the gas supply line before the broiler is mounted on the wall bracket If so install the supply line and connector now but do not yet attach it to the broiler 4 Lift the broiler using two people is recommended and hook the broiler hook over the top of the front of the wall bracket If necessary move the broiler left or right so that the ...

Page 14: ...e rear of the flue riser see Figure 2 on page 5 or will have the optional internal piping to the front manifold of the range For wall mount and countertop models the gas connection 3 8 NPT extends directly out the rear of the broiler near the bottom right rear corner or using an elbow out the top of the broiler near the top right rear corner Minimum supply pressure is 7 W C for natural gas 11 W C ...

Page 15: ...OR VALVE AND OTHER COMPONENTS 4 For the flue riser mounted model either attach the gas supply to the gas pipe extending out of a hole on the rear of the flue riser or if the optional internal piping was ordered connect the gas pipe extending from the rear of the broiler to the corresponding gas pipe extending from the rear of the range below the broiler then attach the wall shield the rear of the ...

Page 16: ...lots see page 18 3 Turn on the broiler burners and check for correct flame appearance and height at both the HIGH and LOW settings When the burners ignite a blue haze type flame will cover the surface of the ceramics but will gradually disappear within two minutes When the burner control is set to HIGH the ceramics should glow red and the flame on the surface of the ceramics should be barely visib...

Page 17: ... Distributor or a Lang Authorized Service Agency When ordering parts please supply the Model Number Serial Number Part Number and Part Description TROUBLESHOOTING Problem Look for Not enough heat Low pressure in gas supply Restriction in gas piping and or valves Misalignment of burner orifice tube Clogged burner orifice Incorrect burner orifice Too much heat Incorrect orifices Defective or incorre...

Page 18: ... The pilots are adjusted at the factory If later the pilots are over adjusted to the point where the flame is leaving its port or blowing off the result is an unstable condition in which the pilot may extinguish If necessary adjust the pilots using the following procedure 1 If necessary light the pilots 2 Locate the pilot adjustment screw which adjusts both pilots It is a small slotted screw locat...

Page 19: ...ler The regulator is preset for 4 W C for natural gas or 10 W C for propane gas If adjustment is necessary do the following 1 Turn broiler control knob to OFF 2 Attach a pressure measuring device to the 1 8 NPT connector located on the front of each burner manifold 3 Turn the broiler control knob to HIGH and with the burners lit check the manifold pressure The pressure should be 4 W C for natural ...

Page 20: ...SE DRAWER SS 1 1192016 SCREW 8x1 4 4 1183210 BODY BOTTOM BACK 36 1 1 1192000 KNOB RED METAL WITH INSERT 2 2 1183219 STIFFENER CAVITY AZ 36 1 1 1192018 KNOB RED BALL 1 1 1183262 COVER 36 1 1 1183279 WEIGHT CONTER BALANCE 2 2 1183263 PLATE HEAT DEFLECTOR 36 1 1 1183287 SPACER BEARING 2 2 1183272 RACK MOUNT ANGLE 36 1 1 1164085 VALVE ASM PILOT 1 1 1192021 PLATE FACE SS 1 1 1192020 NAMEPLATE LANG 1 1 ...

Page 21: ...ER SS 2 1192016 SCREW 8x1 4 4 1183141 BODY BOTTOM BACK 48 1 1 1192000 KNOB RED METAL WITH INSERT 2 2 1183145 STIFFENER CAVITY AZ 48 1 1 1192018 KNOB RED BALL 1 1 1183161 COVER 48 1 1 1183279 WEIGHT CONTER BALANCE 2 2 1183159 PLATE HEAT DEFLECTOR 48 1 1 1183287 SPACER BEARING 2 2 1183155 RACK MOUNT ANGLE 48 1 1 1164085 VALVE ASM PILOT 1 1 1192022 PLATE FACE SS 1 1 1192020 NAMEPLATE LANG 1 1 1183150...

Page 22: ...INFRARED COMPACT BROILER PAGE 22 OF 24 OWNER S MANUAL 1192039 10 09 Notes ...

Page 23: ...INFRARED COMPACT BROILER OWNER S MANUAL 1192039 10 09 PAGE 23 OF 24 Notes ...

Page 24: ...ognize however that replacement parts and occasional professional service may be necessary to extend the useful life of this appliance When service is needed contact a Lang Authorized Service Agency or your dealer To avoid confusion always refer to the model number serial number and type of your appliance Lang Manufacturing International Inc 10 Sunnen Drive St Louis MO 63143 Phone 800 807 9054 Fax...

Reviews: