ETL File# 68964
7
REV. A
INSTALLATION
DANGER
THIS APPLIANCE MUST BE GROUNDED AT THE TERMINAL PROVIDED.
FAILURE TO GROUND THE APPLIANCE COULD RESULT IN
ELECTROCUTION AND DEATH.
WARNING
INSTALLATION OF THE UNIT MUST BE DONE BY PERSONNEL QUALIFIED
TO WORK WITH ELECTRICITY. IMPROPER INSTALLATION CAN CAUSE
INJURY TO PERSONNEL AND/OR DAMAGE TO EQUIPMENT. UNIT MUST BE
INSTALLED IN ACCORDANCE WITH ALL APPLICABLE CODES.
NOTICE
The data plate is on top of the control box. The griddle voltage, wattage,
serial number, wire size, and clearance specifications are on the data plate.
This information should be carefully read and understood before proceeding
with the installation.
NOTICE
The installation of any components such as a vent hood, grease extractors,
fire extinguisher systems, must conform to their applicable National, State
and locally recognized installation standards.
Cabinet Preparation
Cabinet Base must have cross air ventilation. It does not matter if it is on the ends
or sides.
If vents are not installed, the controls may overheat rendering the griddle
inoperative.
For best results provide a knockout for the control panel a minimum of 4½ inches
away from the griddle support surface as shown on next page.
Installing Griddle into Cabinet
Turn the griddle over, taking care not to kink the thermostat capillary tubes.
Set the griddle on the table that it is to be installed in (leaving a hole big enough to
slip the control panel through).
Insert the control panel through the hole and out the control opening of the cabinet.
The hole must be such that the control box can come out of the cabinet 18” for
serviceability.
Lower the griddle plate to sit flat in the table opening.
Electrical Connection
The electrical connection must be made in accordance with local codes or in the
absence of local codes with
NFPA No. 70;
latest edition (in Canada use
: CSA
STD. C22.1
).
A power connection box is provided for power connection.
This box must be installed a minimum of 18 inches away from the heating elements
in the cabinet box.
All electrical connections can be made at this box.
The griddle can now be connected to power.
CAUTION
BE SURE THE POWER SUPPLY VOLTAGE MATCHES THE VOLTAGE
SPECIFIED ON THE NAMEPLATE LOCATED ON THE TOP OF THE CONTROL
BOX
Summary of Contents for LGD
Page 8: ...ETL File 68964 8 REV A INSTALLATION CONT D LGD24 Cabinet Cut out...
Page 9: ...ETL File 68964 9 REV A INSTALLATION CONT D LGD36 Cabinet Cut out...
Page 10: ...ETL File 68964 10 REV A INSTALLATION CONT D LGD48 Cabinet Cut out...
Page 11: ...ETL File 68964 11 REV A INSTALLATION CONT D LGD60 Cabinet Cut out...
Page 12: ...ETL File 68964 12 REV A INSTALLATION CONT D LGD72 Cabinet Cut out...
Page 18: ...ETL File 68964 18 REV A WIRING DIAGRAM 208 240 VOLT...
Page 19: ...ETL File 68964 19 REV A WIRING DIAGRAM 480 VOLT...