41
TROUBLESHOOTING ECCO-C CONT’D
NO HEAT Manual Mode
NOTE:
Fan must be operating before trouble shooting No heat.
PROBABLE CAUSE
CORRECTIVE ACTION
Back-up relay not energizing
!
Check for 240 VAC on relay coil.
If 240 VAC is measured.
Turn unit off and:
!
Check back-up relay coil for 7.2
Ω
.
!
Check “
NO
” contacts for 24 VAC.
!
Replace if defective.
If 240 VAC is not measured:
!
Check back-up switch (SPDT) for normal operation.
!
Replace if defective.
Defective thermostat
!
Turn unit off and check for continuity while cycling thermostat on
and off.
!
Replace if defective.
Defective contactor
!
Check for 24 VAC at heater coil.
If 24 VAC is measured.
Turn oven off and:
!
Check for continuity through coil.
!
Replace if defective.
If 24 VAC is not measured.
Turn oven off and:
!
Check for continuity through hi-temp wires going to over-temp
thermostat.
!
Replace over-temp thermostat if defective.
Defective elements
!
Check elements for continuity.
!
Replace if defective.
Summary of Contents for ECCO-AP
Page 9: ...8 CONTROL PANEL ECCO AP...
Page 10: ...9 CONTROL PANEL LAYOUT ECCO C...
Page 11: ...10 CONTROL PANEL LAYOUT ECCO PP...
Page 13: ...12 CONTROL PANEL ECCO SII...
Page 14: ...13 CONTROL PANEL ECCO T...
Page 28: ...27 GENERAL CONT D ONE PAN TWO PAN THREE PAN FOUR PAN FIVE PAN...
Page 54: ...53 TECHNICAL DATA CONT D ECCO C TEST POINT LAYOUT TP 2 TP 1 TP 3 TP 4 TP5 TP6 TP7...
Page 55: ...55 WIRING DIAGRAM ECCO AP 208 240...
Page 56: ...56 WIRING DIAGRAM ECCO AP 480...
Page 57: ...57 WIRING DIAGRAM ECCO C 208 240...
Page 58: ...58 WIRING DIAGRAM ECCO C 480...
Page 59: ...59 WIRING DIAGRAM ECCO PP 208 240...
Page 60: ...60 WIRING DIAGRAM ECCO PP 480...
Page 61: ...61 WIRING DIAGRAM ECCO PT 208 240...
Page 62: ...62 WIRING DIAGRAM ECCO PT 480...
Page 63: ...63 WIRING DIAGRAM ECCO SII 208 240...
Page 64: ...64 WIRING DIAGRAM ECCO SII 480...
Page 65: ...65 WIREING DIAGRAM ECCO T 208 240...
Page 66: ...66 WIREING DIAGRAM ECCO T 480...