Operation
cont'd.
17
Turning the Buzzer Alarms Off/On
This setting allows the operator to turn the audio (buzzer) temperature alarms off or on
Use the up or down arrow to toggle between “Off” or “On”. Press the ENTER button to save
selection.
Turning the Display Alarms Off/On
This setting allows the operator to turn the visual (display) temperature alarms off or on
Use the up or down arrow to toggle between “Off” or “On”. Press the ENTER button to save
selection.
Alarms
Several alarms exist within the control. These alarms are used as information only messages
or to alert the operator that an unsafe condition may exist.
Alarm Description
Test
Slow Warm Up
Griddle takes to long to get to
operating temperature.
Verify Main Burner ignition, (Spark
Gap, Spark Module, Wiring between
Spark Module and Spark Probe) Gas
Pressure, (5 inches WC NG, 10 inches
WC LP) and Temperature Sense
Probe operation.
Low Temp
Griddle falls more than 25
°
F (-4
°
C)
below set temperature.
Verify main burner ignition, (Spark
Gap, Spark Module, Wiring between
Spark Module and Spark Probe) Gas
Pressure, (5" WC NG, 10 " WC LP)
and Temperature Sense Probe
operation. Review Griddle Loading.
Was Griddle load excessive?
High Temp
Griddle rises more then 25
°
F (-4
°
C)
above set temperature
Check probe, board, and valve for
normal operation.
Failed Temp Probe
Griddle temperature-sensing probe
fails
Check probe for normal operation