4-20
F-524-0410 Edition
OPERATION AND MAINTENANCE
Seed Rate Adjustment
1.
The seeding rate is adjusted for each section with the
seed rate adjustment handle
The
seeding rate should be set the same for all sections.
a.
To set the seeding rate, first determine from the
seed rate chart the meter opening for the desired
seed rate
b.
Loosen the locking nut securing the seed rate
adjustment handle.
c.
The seed rate adjustment handle assembly has
a graduated scale above the handle that
corresponds to the meter opening.
d.
Align the slot in the handle to the appropriate
meter opening.
2.
Do not force the handle or damage may occur to the
meter assemblies. The meter will not be able to be
fully closed if there is seed in the box.
Figure 4-19: Seed Rate Adjustment
LOCKING NUT
SEED RATE
SCALE
SEED RATE
ADJUSTMENT
HANDLE
5530-seed-rate-adj
Summary of Contents for 5530
Page 2: ......
Page 16: ...2 10 F 524 0410 Edition STANDARD SPECIFICATIONS Page Intentionally Blank...
Page 19: ...ASSEMBLY INSTRUCTIONS 3 3 Notes...
Page 20: ...3 4 F 524 0410 Edition ASSEMBLY INSTRUCTIONS Page Intentionally Blank...
Page 63: ...OPERATION AND MAINTENANCE 4 43 Figure 4 41 Lubrication Points 5530 lube 1 2 3 4...
Page 65: ...OPERATION AND MAINTENANCE 4 45 Notes...
Page 66: ...4 46 F 524 0410 Edition OPERATION AND MAINTENANCE Page Intentionally Blank...
Page 69: ......