![Landoll 345F Operator'S Manual Download Page 59](http://html1.mh-extra.com/html/landoll/345f/345f_operators-manual_3547889059.webp)
TROUBLESHOOTING
5-7
SYSTEM OPERATES ERRATICALLY
Air in the system
Check suction side of system for leaks.
Repair leaks.
Cold oil
Allow ample warm-up time. Use proper
weight oil for operating temperature
Dirty or damaged components
Clean or repair as needed
Restriction in filters or lines
Clean and/or replace filter or lines
Not enough oil in system
Fill and check for leaks
SYSTEM OPERATES SLOWLY
Oil viscosity too high, or “cold oil”
Allow oil to warm up before operating.
Low pump drive speed
Increase engine speed (check pump
owners manual for specifications).
Low oil level
Check reservoir and add oil as
necessary.
Air in system
Check suction side for leaks. Repair
leaks.
Badly worn pump, valves, cylinders, etc.
Repair or replace faulty component(s)
as necessary.
Restrictions in lines or filter
Clean and/or replace filter or lines.
Improper adjustments
Check orifices, relief valves, etc. Adjust
as necessary.
Oil leaks
Tighten fittings. Replace seals, gaskets
and damaged lines.
SYSTEM OPERATES TOO FAST
Wrong size or incorrectly adjusted
restrictor
Replace or adjust as necessary.
Engine running too fast
Reduce engine speed
OVER HEATING OF OIL IN SYSTEM
Oil passing through relief valve for
excessive time
Return control valve to neutral when not
in use
Incorrect, low, dirty oil
Use recommended oil
Fill reservoir with clean oil. Replace
filter.
Engine running too fast
Reduce engine speed
Excessive component internal leakage
Repair or replace component as
necessary.
Restriction in filters or lines
Clean and/or replace filter or lines.
Insufficient heat radiation
Clean dirt and mud from
reservoir and components.
Malfunctioning component
Repair or replace
Excess oil going to dock level circuit
Adjust flow divider for 2.5 to 3.1 GPM
flow.
FOAMING OF OIL
Incorrect, low, dirty oil
Replace, clean, or add oil as needed
Air leaks
Check suction line and component seals
for suction leaks. Replace defective
parts.
NOISY PUMP
Low, incorrect, foamy oil
Replace, clean, or add oil as needed
Suction line plugged
Clean out obstruction or replace line.
Flush system, replace filter
LEAKY PUMP
Damaged or worn shaft seal
Replace seal and check for
misalignment
Loose or broken parts
Tighten or replace
PROBLEM
PROBABLE CAUSE
SOLUTION
Summary of Contents for 345F