5-7 DOCK LEVEL HYDRAULICS
SYMPTOM
PROBLEM: REMEDY
FAILS TO LIFT TRAILER
Insufficient hydraulic supply pressure:
adjust relief valve for
2400-2500 psi.
Worn hydraulic pump:
service or replace.
Insufficient volume to dock level circuit:
adjust flow divider to
provide 2.5 to 3.1 GPM.
Too heavy a load:
reduce load on cylinders.
LOWERS UNEVENLY OR
ERRATICALLY
Insufficient volume to dock level circuit:
clean system and new
oil and filter.
Dirty oil in check valves:
use same procedure as above.