Aligning electronic unit 

Proceed as follows to align the electronic unit: 

 

Turn the electronic unit to the left or right through 90° or 
through 180° as required. 

 

Note: 

When  turning  through  45°  the  electronic  unit  is 

not connected tightly to the volume measurement unit. 

Wall fitting (split fitting) 

Fit  the  meter  to  the  wall  at  water  temperatures  below  10 °C. 
Proceed as follows: 

 

Fit the wall adapter plate (available as an accessory). 

 

Turn the electronic unit through 45°. 

 

Pull the electronic unit away from the volume measurement 
unit. 

 

Place the electronic unit on the wall adapter at an angle of 
45° and turn it into position. 

3.3 

Power supply 

The meter is equipped with a long life battery for 6 or 11 years 
of  operation.  You  can  take  the  operating  time  from  the  dial 
plate. 

 

Warning: 

Do  not  open  the  batteries.  Do  not  bring 

battery  into  contact  with  water  or  expose  to  tempera-
tures  above 80 °C.  Dispose  of  used  batteries  at suita-
ble collection points. 

3.4 

Interfaces and Communication 

The meter is equipped with an optical interface in accordance 
with  EN  62056-21  as  standard.  If  the  meter  is  equipped  with 
the option "M-Bus", it is supplied with a 2-wire cable which you 
can extend by fitting a junction box. 

3.5 

Temperature sensor 

 

Note:

  Wires  must  not  be  separated,  shortened  or 

extended. 

4. 

Operating 

 

Note:

 Both display range and data displayed can differ 

from  this  description  depending  on  the  appliance  pa-
rameterisation.  Certain  button  functions  can  also  be 
blocked. 

The meter consists of a 7-digit LCD displaying various values. 

 

Fig.6: LCD 

 

Number 

Description 

Identification previous year value  

Previous year value 

Maxima 

Previous month value  

Identification previous month value  

Activity display at flow  

Calibrated value  

Switching the display 

Proceed as follows to switch between the display values: 

 

Press the button briefly (for less than 2 sec.) to show the 
next line of the current loop. 

After the last line is displayed, the first line comes up again. 

 

Hold down the button (longer than 3 sec.) in order to dis-
play the next loop. 

After the last loop is displayed, the first loop comes up again.  
If  you  do  not  operate  the  meter  for  30  sec.  in  the  user  loop 
"LOOP 0", the meter changes to the standard display. If you do 
not operate the meter for 30 min. in the loops "LOOP 1 ... 4", 
the meter changes to the standard display. 

User loop “LOOP 0” 

 

User loop 

 

 

 

Energy quantity 

 

 

Segment test 

 

Volume 

 

In case of error: message 
with error code 

Current values “LOOP 1” 

 

Current values 

 

Current flow 

 

Temperature difference 

 

Current heat power 

 

Operating time with flow 

 

Alternate current 
temperature hot and 

cold side in 2 s cycles 

 

Missing time 

 

 

Time with flow 
 

Previous month's values “LOOP 2” 

 

Previous month's values 

 

Log date 

  Max. power in 2 s cycles 

with date stamp 

 

Energy quantity and 
volume on set day 

 

 

 

Max. temperature hot 
side in 2 s cycles with 

date stamp 

 

Missing time on set day 

 

 

Max. flow on set day in 

2 s cycles with date 
stamp 

 

Max. temperature cold 

side in 2 s cycles with 
date stamp 

 

 

General/Communication "LOOP 3" 

 

General/Communication 

 

Device number,  
7-digit 

 

Yearly set day 

 

Optional interface 

 

Monthly set day 

 

Primary address (only 

for M-Bus) 

 

Firmware version 

 

Secondary address  

7-digit - for M-Bus 

 

CRC-Code 

Other “LOOP 4” 

 

Other 

 

Date 

 

Code entry for test /  

para operation 

 

Time 

 

 
 

Summary of Contents for ULTRAHEAT T230

Page 1: ...systems The meter is not suitable for drinking water Adhere to the AGFW requirements regarding circulat ing water FW510 Only personnel trained in the installation and opera tion of meters in heating and cooling systems may install and remove the meter Only install or remove the meter when the pipes are pressure less After installing the meter check the leak tightness of the system Guarantee and ca...

Page 2: ...the seal with cupling nut is sufficient Recommendation Do not install the meter on the pressure side of a pump Maintain a minimum distance of 10 x DN on the pressure side Note During installation it must be ensured that no water can enter the electronic unit during operation Examples of installation directly immersed sensor You can install the meter in any position e g vertically or hori zontally ...

Page 3: ...git LCD displaying various values Fig 6 LCD Number Description 1 Identification previous year value 2 Previous year value 3 Maxima 4 Previous month value 5 Identification previous month value 6 Activity display at flow 7 Calibrated value Switching the display Proceed as follows to switch between the display values Press the button briefly for less than 2 sec to show the next line of the current lo...

Page 4: ...ation thresholds are exceeded and flow and temperature difference are positive the meter summates the energy and the volume If the operate margin is gone below a u is displayed at a leading point for the flow power and temperature display For a positive flow the activity display appears in the user loop in the LCD All segments of the display are switched on for control purpos es during the segment...

Page 5: ...5 mm Temperature range 0 95 C Volume measurement unit Protection class IP 65 according to EN 60529 Mounting place Hot side cold side Installation position Any Flow straightening None Measuring range 1 100 Temperature range 5 90 C National type approvals may be different Maximum overload qs 2 x qp permanent Nominal pressure PN16 1 6 MPa PS16 qp m h Overall length and connection 0 6 110 mm 3 4 1 5 1...

Page 6: ...Landis Gyr GmbH Subject to change without prior notice 13 06 2017 6 10 Declaration of conformity Landis Gyr GmbH Humboldtstrasse 64 90459 Nuremberg Germany ...

Reviews: