10/35
Released
Liquid Crystal Display Indications
© Gyr (Pty) Ltd
Cashpower Gemini HMI
– User Guide
4
Liquid Crystal Display Indications
The LCD is designed to give a clear and unambiguous visual indication of the important meter functions
by means of language-independent pictograms:
Figure 6: What the ICONS mean
Figure 7: Operational Displays
1
- Happy face
2
- Sad Face
3
- Alarm indicator
4
- Load switch status indicator
5
- Remaining credit indicator
6
- Information mode
7
- Currency function
8
- Power (kWh) function
9
- Not used
10
- Eight X 7 segment digits
Normal Operation
Zero Credit
Display shows
remaining credit
(kWh).
Load switch closed and consumption
rate
indicator flashes at a rate
proportional to the power being used.
Credit running low and more needs to
be purchased to avoid disconnection
of supply.
Supply disconnected.
Low Credit Warning
Power Limit Lockout
Supply disconnected.
Energy Limiting
Mode
Display shows the amount of
accumulated energy
currently
available. The credit wedge will always
be scrolling
– up, if energy credit is
accumulating, or down, if it is
decreasing.
Scrolling wedge