CA02B.C01
Service instructions, mixer type POPR-I
Page 3/8
Landia Inc.
Issued on: 12. mar. 2003
Cary, NC 27513
Rev. date: 22 november 2017
Executed by: AJ/BNV
Accepted by: SL/KT
RATING PLATE
Type:
Unit type
3~mot.nr.:
Serial no.
V:
Connection voltage, star/delta
In:
Nominal power consumption at full load
Ist:
Start current direct
Hz:
Mains frequency
HP:
Max. shaft power
IP:
Cage class
Cos
:
Power factor
RPM:
Motor revolutions per minute
kg:
Weight of unit
Year:
Year of manufacture
Ins.Cl. F:
Insulation class F
Duty type S1: Continuous working period
The rating plate states the motor's electrical data as well as the year of manufacture and the serial no.
(3~Mot.nr.). With regard to maintenance of a specific unit please state serial no. when contacting Landia.
PLEASE NOTE
It is important that the electrical cable is tightened to
prevent the cable from getting into contact with the
propeller. The cable can be secured against damage by
means of a cable mesh or a chain.
POWER CONNECTION
Every mixer is equipped with the above mentioned rating plate with technical motor data. It must be verified
that the other electrical parts correspond to the motor data. For each mixer there is an electrical diagram. A
protective motor switch must be applied at connection of the mixer the mains.
Only a certified electrician is allowed to connect the unit.