background image

PDE SERIES PRESSURE WASHER  

OPERATOR’S MANUAL

5

LANDA PDE  •  REV. 9/02

9. Never make adjustments on machine while in op-

eration.

WARNING: High pressure spray
can cause paint chips or other
particles to become airborne and
fly at high speeds.

10. Eye safety devices, foot protec-

tion and protective clothing
must be worn when using this
equipment.

11. Do not operate with the trigger

in the off position for extensive periods of time as
this may cause damage to the pump.

12. The best insurance against an accident is precau-

tion and knowledge of the machine.

13. Landa will not be liable for any changes made to our

standard machines, or any components not pur-
chased from Landa.

14. Be certain all quick coupler fittings are secured be-

fore using pressure washer.

15. Never run pump dry or leave spray gun closed longer

than 5 minutes.

16. Inlet water supply must be cold and clean fresh wa-

ter.

17. To reduce the risk of injury, close supervision is nec-

essary when a machine is used near children. Do
not allow children to operate the pressure washer.
This machine must be attended during opera-
tion.

18. Protect from freezing.

19. When the machine is working, do not cover or place

in a closed space where ventilation is insufficient.

PRE-OPERATION CHECK

 Pump oil (SAE 30W non-detergent oil)

 Clean, fresh, cold water supply (5 gpm • 5/8" • 20 psi)

 Hose, wand, nozzle (nozzle size per serial plate)

 Water filter (intact, non restrictive)

 Proper electrical supply, receptacle and circuit breaker.

SET-UP PROCEDURES

These machines are designed for indoor use.
Machine must be stored indoors when not in use.

  1. Attach a 5/8" garden hose to inlet connector. Mini-

mum flow should be 5 gpm.

  2. Attach high pressure hose to discharge nipple using

quick coupler. Lock coupler securely into place by
pulling back coupler collar and inserting it onto dis-
charge nipple, then pushing collar forward to lock in
place.

  3. Attach wand to spray gun using teflon tape on threads

to prevent leakage.

  4. Attach connector on discharge hose to spray gun

using teflon tape on threads.

  5. Remove oil plug on top of pressure washer pump

and replace with dipstick supplied.  (This may be
installed from the factory.)

  6. Check oil level on oil dipstick on top of pump. Oil

should be visible one half way up sight glass (30W
non-detergent).

  7. For operator safety and to comply with electrical stan-

dards, the PDE2-15021D comes with a 120V 20 amp
plug end that will fit only into a 20 amp receptacle.

  8. On 230V machines, attach appropriate plug end (not

included) to power cord.

OPERATING INSTRUCTIONS

  1. With power switch in OFF position, plug power cord

into a grounded type of receptacle of proper voltage
and amperage reading. Then push GFCI reset but-
ton at end of power cord if required.

  2. Turn on water at faucet and pull trigger on spray gun

allowing  water to flow until all air has discharged
from system. Check for water leaks; tighten as
needed.

  3. Pull wand coupler collar back and insert pressure

nozzle into coupler then secure by pushing collar
forward.

  4. With spray gun off, turn power switch to ON position

and check for leaks.

  5. With spray nozzle pointed away from you or any-

body else, press  trigger on spray gun to obtain pres-
surized spray.

GENERAL WASHING
TECHNIQUES

  1. Hold spray nozzle approximately one foot from the

surface being cleaned. Spray at an angle to get un-
der the material and lift it off.

  2. When washing large objects, use detergent injector

to apply detergent (see section “How to Use the De-
tergent Injector”). Start washing from the bottom and
work up. Better detergent economy and faster re-
sults will be obtained by allowing the detergent to
set 5-10 minutes. After washing, rinse from the top
down.

  3. Cleaning heavy dirt or material away with a hard

stream of clear water is recommended before using
a cleaning agent.

WARNING

PROTECTIVE

EYEWEAR AND

CLOTHING MUST

BE WORN.

Summary of Contents for ? PDE4-3000

Page 1: ...NC 4275 N W Pacific Rim Blvd Camas WA 98607 USA For technical assistance or the Landa Dealer nearest you call 800 LANDA 4 U 800 526 3248 or 360 833 9100 or consult our web page at www landa com PDE2 1...

Page 2: ......

Page 3: ...n 4 Important Safety Instruction 4 5 Pre Operation Check 5 Set Up Procedures 5 Operating Instructions 5 General Washing Techniques 5 Shut Down Procedures 6 Component Identification 7 How To Use the De...

Page 4: ...re doing 4 All installations must comply with local codes Con tact your electrician plumber utility company or the selling distributor for specific details To comply with the National Electrical Code...

Page 5: ...ge nipple then pushing collar forward to lock in place 3 Attach wand to spray gun using teflon tape on threads to prevent leakage 4 Attach connector on discharge hose to spray gun using teflon tape on...

Page 6: ...f water supply 4 Open spray gun to relieve remaining pressure 5 Remove water supply hose 6 In freezing conditions disconnect water supply and open spray gun to allow water to drain then turn off motor...

Page 7: ...Pressure Hose Pressure Nozzle Brass Soap Nozzle Oil Dip Stick Power Supply Nozzles On Off Switch Water Supply Hose not included Collar Quick Coupler Detergent Injector Swivel Connector GFCI Trigger W...

Page 8: ...gent ratio is approxi mately 15 to 1 7 When you finish washing rinse by simply releasing the spray gun removing the soap nozzle and re placing the pressure nozzle back into quick coupler NOTE The dete...

Page 9: ...5021A PDE4 20021A EXPLODED VIEW 30 39 35 32 46 29 34 43 45 40 4 2000 4 3000 Models Only 16 17 26 28 37 20 2 1 36 41 35 42 40 36 38 12 13 20 20 13 28 38 36 36 13 13 28 22 3 7 22 37 10 13 20 29 13 23 25...

Page 10: ...Pump AR 4 20025 1 18 5 3024 Unloader General YVB175 2 11021D 2 15021D 3 15021A 4 20021A G 1 5 3203 Unloader 4 20025 1 ITEM PART NO DESCRIPTION QTY 18 5 3204 Unloader 3 15025A 2 15025D 2 11025D 1 19 90...

Page 11: ...3 44 6 05181 Locknut 1 2 1 45 90 017 Nut 10 32 KEPS 5 46 6 051595 Straight Strain Relief Plastic 2 15021D 3 15021A Qty 1 4 20021A QTY 2 47 4 12803015 Nozzle SAQMEG 1503 Yellow 2 15021D 1 4 12804015 No...

Page 12: ...PDE REV 9 02 PDE4 30025A B C EXPLODED VIEW 32 3 43 25 27 26 6 23 28 45 9 41 7 19 31 46 24 30 8 44 33 29 32 16 30 48 16 32 30 30 30 30 48 32 48 37 8 33 29 13 34 29 30 32 36 21 18 12 35 1 10 4 2 14 22...

Page 13: ...05171 Strain Relief 1 4 3000B C 1 20 5 2263 Pump AR RKA35G30E F17 1 21 10 08028 Tag Remove Pump Plug 1 22 5 3203 Unloader AR 20242G 3 4 GPM 3500 PSI Black Knob 1 ITEM PART NO DESCRIPTION QTY 23 6 202...

Page 14: ...1831 Detergent Injector Assy 1 2 GPM 0 57 2 1100 1 3 1202 Injector Det Non Adj 2 3 GPM 0 70 1 4 011183 Detergent Injector Assy 2 3 GPM 0 70 2 1500 3 1500 1 3 12021 Injector Det Non Adj 3 5 GPM 0 83 1...

Page 15: ...1A 3 15025A 4 20021A 4 20025A 4 30025A B C 1 3 4 01212 Spray Gun Shut off Series 2000 1 4 4 0110410 Wand SS 31 4 w Coupler 4 2000 1 4 4 0110540 Wand SS 42 4 30025A B C 1 5 See Exploded View Parts Brea...

Page 16: ...ck and clean if necessary Worn bearings Check and replace if necessary Excessive temperature of water Reduce to below 160o F PRESENCE OF WATER IN PUMP OIL Oil seal worn Check and replace if necessary...

Page 17: ...ent Contact your Landa Inc dealer for maintenance Regular preventative maintenance will add many hours to the life of your pressure washer Perform maintenance more often under severe conditions Pump O...

Page 18: ...uding adjustments fuel system cleaning and clearing of obstructions 6 Transportation to service center field labor charges or freight damage WHAT YOU MUST DO TO OBTAIN WARRANTY SERVICE While not requi...

Page 19: ...que fatal Lea la etiqueta de advertencia del cable electrico 3 Para proteger al operador de un choque el ctrico la m quina deber de estar conectada a tierra Es la responsabilidad del due o de conectar...

Page 20: ...onecte una manguera de alta presi n a la boquilla de descarga usando una conexion r pida Asegure el conector ajust ndolo en su lugar tirando el collar del enganche trasero hacia atr s e insert dolo en...

Page 21: ...lla de Cobre para Detergente Manguera de Suministro de Agua no se incluye Inyector de Detergente Enganche Rapido Tanque para Detergentes no se incluye Manguera para Detergentes Cople de Varilla Varill...

Page 22: ...de agua limpia antes de usar el agente limpiador PROCEDIMENTOS DE APAGADO 1 Enjuage todas las l neas inyector con agua lilmpia para remover residuos de jab n 2 Apague la m quina 3 Cierre la llave de...

Page 23: ...tergente en el recipiente de la soluci n de detergente 5 Instale la boquilla de cobre para detergente proporcionada une con el inyector en el enganche r pido de la varilla 6 Abra el gatillo de la pist...

Page 24: ...a 4 Da o a los componentes debido a fluctuaciones en el suministro el ctrico o al abastecimiento de agua 5 Servicio de mantenimiento normal incluso los ajustes limpieza del sistema de combustible y de...

Page 25: ......

Page 26: ...4275 NW Pacific Rim Blvd Camas WA 98607 USA Form 96 620 Revised 9 02 Printed in U S A by Landa Inc Camas WA 98607 WATER CLEANING SYSTEMS...