background image

ENG  •  9.801-511.0  •  Rev. 9/13a

5

  PRESSURE 

W

ASHER  

DEALE

R’S MANU

AL

  

IMPORTANT SAFETY INFORMATION

WARNING

USE PROTECTIVE  

EYE WEAR 

AND CLOTHING  

WHEN OPERATING 

THIS EQUIPMENT.

WARNING: High pressure spray 

can cause paint chips or other 
particles to become airborne 
and fly at high speeds. To avoid 
personal injury, eye, hand and 
foot safety devices must be 
worn.

  9.   Eye, hand, and foot protec-

tion must be worn when  
using this equipment.

WARNING

EAR PROTECTION 

MUST BE WORN

WARNING: This machine ex-

ceeds 85 db appropriate ear 
protection must be worn.

WARNING

RISK OF INJURY.  

HOT SURFACES  

CAN CAUSE BURNS

WARNING: Risk of injury. Hot 

surfaces can cause burns. Use 
only designated gripping areas 
of spray gun and wand. Do not 
place hands or feet on non-in-
sulated areas of the pressure 
washer.

 

 10.  To reduce risk of injury, close supervision is neces

-

sary when a machine is used near children. Do not 
allow children to operate pressure washer. 

This 

machine must be attended during operation.

 

TRIGGER GUN KICKS 

BACK - HOLD WITH  

BOTH HANDS

WARNING

WARNING: Grip cleaning wand 

securely with both hands be-
fore starting. Failure to do this 
could result in injury from a 
whipping wand.

11.   Never make adjustments on 

machine while in operation.

12.  Be certain all quick coupler 

fittings are secured before 
using pressure washer.

RISK OF INJECTION 

OR SEVERE INJURY 

TO PERSONS. KEEP 

CLEAR OF NOZZLE.

WARNING

WARNING: High pressure de-

veloped by these machines will 
cause personal injury or equip-
ment damage. Keep clear of 
nozzle. Use caution when op-
erating. Do not direct discharge 
stream at people, or severe 
injury or death will result. 

 

WARNING

PROTECT FROM 

FREEZING

WARNING: Protect machine 

from freezing.

13.  To  keep  machine  in  best 

 

 

operating conditions, it is  

 

important you protect machine  

 

from freezing. Failure to protect  

 

machine from freezing  

 

could cause malfunction of the  

 

machine and result in death, 

serious bodily injury, and/or property damage. Fol

-

low storage instructions specified in this manual.

 

WARNING

RISK OF 

ASPHYXIATION. USE 

THIS PRODUCT ONLY 

IN A WELL 

VENTILATED AREA.

WARNING: Risk of asphyxiation. 

Use this product only in a well 
ventilated area. 

 14.  Avoid installing machines in 

small areas or near exhaust 
fans. Adequate oxygen is 
needed for combustion or 
dangerous carbon monoxide 
will result.

 15. Manufacturer will not be liable for any changes 

made to our standard machines or any compo-
nents not purchased from us.

 16.  The best insurance against an accident is precau-

tion and knowledge of the machine.

WARNING

RISK OF INJURY 

FROM FALLS WHEN 

USING LADDER.

WARNING: Be extremely careful 

when using a ladder, scaffold-
ing or any other relatively un-
stable location. The cleaning 
area should have adequate 
slopes and drainage to reduce 
the possibility of a fall due to 
slippery surfaces.

 

 17.  Do not overreach or stand on unstable support. 

Keep good footing and balance at all times.

 18. Do not operate this machine when fatigued or 

under the influence of alcohol, prescription medi-
cations,  or drugs.

19.   Follow the maintenance instructions specified in 

the manual.

WARNING: Use vapor fuel only.

20.   The LP models are designed to run on vapor pro

-

pane fuel. Do not use liquid fuel. Have a qualified 
serviceman install and service your equipment.

 21.  Never expose a spark or flame where there may 

be unburned gas present.

Summary of Contents for ENG4-2000

Page 1: ...RN whe n ope ratin g this mac hine PRO TEJ ASE LOS OJO S CU AND O se oper e este equi po DES LUN ETT ES DE SEC URIT E DOI VEN T ETR E POR TEE S lorsq ue vous oper ez cet appa reil RIS K OF ASP HYX IA...

Page 2: ...it means the overload is tripped Reset overload Pilot Light When the light is on it means there is power to the pilot control If there is no light see troubleshooting guide Voltage When the light is o...

Page 3: ...5 3000 8 Installation ENG 6 3200 8 3200 10 3000 9 Installation 10 16 Assembly Instructions 17 Operating Instructions 18 Applying Detergent General Washing Techniques 19 Shutting Down Cleanup 20 Storag...

Page 4: ...familiar with the controls 3 Stay alert watch what you are doing 4 Use only your hand to push in or turn the gas control knob Never use a tool If the knob will not push in or turn by hand don t try t...

Page 5: ...charge stream at people or severe injury or death will result WARNING PROTECT FROM FREEZING WARNING Protect machine from freezing 13 To keep machine in best operating conditions it is importantyouprot...

Page 6: ...RNING If connection is made to potable water supply a back flow device must be provided 27 Exhaust gases should not be vented into a wall a ceiling or a concealed space of a building A draft diverter...

Page 7: ...IC ADO S LIRE LE MAN UEL DE L OP ERA TEU R AVA NT UTIL ISAT ION CET APP ARE IL DOIT ETR E UTIL ISE PAR DES OPE RA TEU RS QUA LIFIE S RIS K OF INJU RY PRO TEC TIVE EYE WE AR AND CLO THI NG MUS T BE WO...

Page 8: ...Panel 19 50 Dia Customer Supplied Draft Diverter 24 00 24 87 4 00 High Pressure Out 3 8 QC Nipple 48 54 36 68 24 50 24 00 12 00 49 00 Water In 3 4 GHF 21 30 20 61 20 61 Exhaust Out 10 Dia NOTE Draft d...

Page 9: ...to Outside Floor Mounting Dimensions 19 50 Dia Customer Supplied Draft Diverter Control Panel 61 00 17 33 34 79 17 36 26 18 3 64 High Pressure Out 3 8 QC Nipple 31 77 64 00 26 91 26 91 Water In 3 4 G...

Page 10: ...ecommended that a partition be made be tween the wash area and machine to prevent direct spray from the spray gun from coming in contact with the machine Excess moisture reaching the power unit or ele...

Page 11: ...ed by the Uniform Building Code Vents penetrating ceilings or walls should be double wall approved appliance vents and should be one to INSTALLATION LP Gas Liquid petroleum gas or propane LP gas is ga...

Page 12: ...roof power venting is recommended to help eliminate exhaust restriction of this natural draft machine This draft inducer power vent must be installed by a li cenced contractor who can calculate size o...

Page 13: ...nced by the heat created inside the coil the design of the coil and flue and the length and diameter of the exhaust stack The table below shows data included in the operator s manual for flue and stac...

Page 14: ...4 2 wc in For an installation at 3500 feet reduce this pressure by 16 by setting the manifold pressure to 4 2 84 3 5 wc in This adjustment should only be made by a properly trained service technician...

Page 15: ...w instructions carefully when installing or servicing machine Failure to do so may result in damage to property or personal injury 1 Installation or servicing of gas appliances and controls must only...

Page 16: ...for the BTU rating of the burner Is incoming gas supply pressure between 6 14 water column inches or 1 2 PSIG Has the proper gas regulator been installed for pressure and volume Have you installed the...

Page 17: ...garden hose to the cold water source Cold Water Source Garden Hose 98015100 10 STEP 6 Pull the spring loaded collar of the wand coupler back to insert pressure nozzle Release the coupler collar and p...

Page 18: ...ent Valve STEP 4 To apply detergent open the detergent valve counterclock wise making sure that the deter gent pick up tube is in the detergent solution and not sucking air 98015100 17 NOTE High press...

Page 19: ...thermal device prevents internal damage to the pump CLEANING TIPS Pre rinse cleaning surface with fresh water Place detergent suction tube directly into cleaning solu tion and apply to surface For be...

Page 20: ...syst me F Coupez l eau W ARNIN G PRE CAU CION AVE RTIS SEM ENT SK AL E NE BY ORS LEA EL MANUA L OPERA CION ANTES DE USARS E ESTE EQUIPO DEBE SER USADO SOLAM ENTE POR OPERA DORES CALIFIC ADOS LIRE LE M...

Page 21: ...metering valve Disassemble and clean thoroughly High viscosity of detergent Dilute detergent to specifications Restriction behind float tank screen removed Install restriction Hole in detergent line s...

Page 22: ...pair kit when needed Worn packing in pump Install new packing kit Fouled or dirty inlet or discharge valves in pump Clean inlet and discharge valve Worn inlet or discharge valves Replace with valve ki...

Page 23: ...1 Be sure main gas valve gas cock or selector arm is turned on 2 With gas on and system sparking probe terminals PV and 24V GND If pilot gas does not flow with 24 volts at these terminals replace gas...

Page 24: ...on With the pilot burning and the flame on the ignitor sensor rod the main burner should turn on If it does not replace the ignition control unit SHORT CYCLING OF MAIN BURNER MAIN BURNER TURNS OFF BE...

Page 25: ...needs repairing CAUTION When using this procedure to test compo nents keep the spray gun open at all times High Limit Hot Water Thermostat For safety each machine is equipped with a high limit control...

Page 26: ...d Exterior regulators are needed to control gas pressure Propane bottles are not included with the machine A pressure regulator should be installed between pro pane bottle and gas valve Propane Cylind...

Page 27: ...ugh the coil by whatever means are available for the particular system the water heater is used on To Adjust Pressure Regulator Adjustment of the pressure regulator is not normally necessary since it...

Page 28: ...per Gal Liquid 4 23 4 87 BTU per Cu Ft Vapor 2 563 3 39 BTU per Gal Liquid 91 547 102 032 BTU per Lb Liquid 21 591 21 221 Cu Ft per Lb Liquid 8 607 6 53 Cu Ft per Gal Liquid 36 45 31 8 Octane Number...

Page 29: ...ure gauge At the lower levels it is expressed in water column inches i e 11 w c i Higher pressures are expressed in terms of the force exerted against a square inch of area for example 125 lbs per squ...

Page 30: ...ife of your pressure washer Perform maintenance more often under severe conditions MAINTENANCE SCHEDULE Replace Fuel Lines Annually Pump Oil Inspect Daily inspect the oil level Change After first 50 h...

Page 31: ...nter field labor charges or freight damage WHAT YOU MUST DO TO OBTAIN WARRANTY SERVICE While not required for warranty service we request that you register your LANDA pressure washer by returning the...

Page 32: ...Form 9 801 511 0 Revised 9 13a Printed in U S A...