ENG  •  9.801-511.0  •  Rev. 9/13a

DEALER’S MANU

AL

    

PRESSURE 

W

ASHER  

10

INSTALLATION

Install a gas union in the gas line adjacent to and up-
stream from the control manifold and downstream from 

the manual main shut-off valve. A 1/8" NPT plugged 

tapping accessible for test gauge connection shall 
be installed immediately upstream of the gas supply 
connection for the purpose of determining the gas 

supply pressure to the burner, and to prevent damage 
to gas valve.
If a manual gas shut off valve is not in the gas supply 

line within six feet of the machine and in an accessible 
location, one shall be installed.

Figure 1: Union Location

Union Connection

The following pipe sizes are just recommendations. 

Always consult a local plumber and venting contrac

-

tor for local codes and regulations during installation.

Pipe Sizing Chart for Natural Gas

The following chart is based on gas pressure in the 

range 0-0.5 psi, specific gravity of 0.6 and pressure 

loss of 0.5" W.C. Numbers are for straight schedule 

40 pipe; fittings further reduce capacity. For example, 
in 1" size, an elbow is equivalent to about 2.6 feet of 
pipe and a tee is equivalent to about 5.2 feet of pipe.

Maximum capacity of pipe in cubic feet/hr of natural gas 

(Multiply values by 1000 to get nominal BTU/hr capacity.

Place machine in a convenient location providing ample 

support, drainage and room for maintenance (pgs 8-9).

Location:

The location should protect machine from damaging en-

vironmental conditions, such as wind, rain and freezing.
  1.  The  machine  should  be  run  on  a  level  surface 

where it is not readily influenced by outside sourc-
es such as strong winds, freezing temperatures, 
rain, etc. The machine should be located consider-
ing accessibility for the replacing of components 
and the refilling of detergents, adjustments and 
maintenance. Normal precautions should be taken 

by the operator of the machine to prevent excess 

moisture from reaching the machine.

  2. It is recommended that a partition be made be-

tween the wash area and machine to prevent direct 

spray from the spray gun from coming in contact 
with the machine. Excess moisture reaching the 
power unit or electrical controls will reduce the 
machine’s life and may cause electrical shorts.

  3.  During  installation  of  the  machine,  beware  of 

poorly ventilated locations or areas where exhaust 

fans may cause an insufficient supply of oxygen. 
Sufficient combustion can only be obtained when 

there is a sufficient supply of oxygen available for 

the amount of fuel being burned. If it is necessary 

to install a machine in a poorly ventilated area, out

-

side fresh air may have to be piped to the burner 

and a fan installed to bring the air into the area.  

  4.   Do not locate near any combustible material. Keep 

all flammable material at least 20 feet away.

    Allow enough space for servicing the machine.

    Local code will require certain distances from floor 

and walls. (Two feet away should be adequate).

WARNING: Avoid small areas or near exhaust fans. 

Gas Codes:

Confer with local gas company and with proper mu-
nicipal officials regarding any specific code or regula-

tions governing the installation. The installation must 

conform to local codes (NFPA 54).

Electrical:

The machine, when installed, must be electrically 
grounded in accordance to local codes. Check for 

proper  power  supply  using  a  volt  meter;  check  the 

serial plate for the correct requirements.

Gas Piping:

This machine shall be rigidly connected to the gas pip-
ing outlet and equipped with external manual shut-off 

valves adjacent to such machine. All gas piping shall 
be  approved  and  installed  in  accordance  with  the 

Uniform Mechanical Code.

98015100-25

Manual  

Shut-Off 

Valve

1/8" NPT Plugged Pressure Gauge  

Port Location

Union

Drop

Floor Level

Length of 

Pipe (ft.)

Iron Pipe Size

3/4"

1"

1 -1/4" 1- 1/2"

2"

10

360

680

1400

2100

3950

20

250

465

950

1460

2750

30

200

375

770

1180

2200

40

170

320

660

990

1900

50

151

285

580

900

1680

60

138

260

530

810

1520

70

125

240

490

750

1400

80

118

220

460

690

1300

90

110

205

430

650

1220

100

103

195

400

620

1150

150

84

160

325

500

950

200

72

135

280

430

800

Summary of Contents for ENG4-2000

Page 1: ...RN whe n ope ratin g this mac hine PRO TEJ ASE LOS OJO S CU AND O se oper e este equi po DES LUN ETT ES DE SEC URIT E DOI VEN T ETR E POR TEE S lorsq ue vous oper ez cet appa reil RIS K OF ASP HYX IA...

Page 2: ...it means the overload is tripped Reset overload Pilot Light When the light is on it means there is power to the pilot control If there is no light see troubleshooting guide Voltage When the light is o...

Page 3: ...5 3000 8 Installation ENG 6 3200 8 3200 10 3000 9 Installation 10 16 Assembly Instructions 17 Operating Instructions 18 Applying Detergent General Washing Techniques 19 Shutting Down Cleanup 20 Storag...

Page 4: ...familiar with the controls 3 Stay alert watch what you are doing 4 Use only your hand to push in or turn the gas control knob Never use a tool If the knob will not push in or turn by hand don t try t...

Page 5: ...charge stream at people or severe injury or death will result WARNING PROTECT FROM FREEZING WARNING Protect machine from freezing 13 To keep machine in best operating conditions it is importantyouprot...

Page 6: ...RNING If connection is made to potable water supply a back flow device must be provided 27 Exhaust gases should not be vented into a wall a ceiling or a concealed space of a building A draft diverter...

Page 7: ...IC ADO S LIRE LE MAN UEL DE L OP ERA TEU R AVA NT UTIL ISAT ION CET APP ARE IL DOIT ETR E UTIL ISE PAR DES OPE RA TEU RS QUA LIFIE S RIS K OF INJU RY PRO TEC TIVE EYE WE AR AND CLO THI NG MUS T BE WO...

Page 8: ...Panel 19 50 Dia Customer Supplied Draft Diverter 24 00 24 87 4 00 High Pressure Out 3 8 QC Nipple 48 54 36 68 24 50 24 00 12 00 49 00 Water In 3 4 GHF 21 30 20 61 20 61 Exhaust Out 10 Dia NOTE Draft d...

Page 9: ...to Outside Floor Mounting Dimensions 19 50 Dia Customer Supplied Draft Diverter Control Panel 61 00 17 33 34 79 17 36 26 18 3 64 High Pressure Out 3 8 QC Nipple 31 77 64 00 26 91 26 91 Water In 3 4 G...

Page 10: ...ecommended that a partition be made be tween the wash area and machine to prevent direct spray from the spray gun from coming in contact with the machine Excess moisture reaching the power unit or ele...

Page 11: ...ed by the Uniform Building Code Vents penetrating ceilings or walls should be double wall approved appliance vents and should be one to INSTALLATION LP Gas Liquid petroleum gas or propane LP gas is ga...

Page 12: ...roof power venting is recommended to help eliminate exhaust restriction of this natural draft machine This draft inducer power vent must be installed by a li cenced contractor who can calculate size o...

Page 13: ...nced by the heat created inside the coil the design of the coil and flue and the length and diameter of the exhaust stack The table below shows data included in the operator s manual for flue and stac...

Page 14: ...4 2 wc in For an installation at 3500 feet reduce this pressure by 16 by setting the manifold pressure to 4 2 84 3 5 wc in This adjustment should only be made by a properly trained service technician...

Page 15: ...w instructions carefully when installing or servicing machine Failure to do so may result in damage to property or personal injury 1 Installation or servicing of gas appliances and controls must only...

Page 16: ...for the BTU rating of the burner Is incoming gas supply pressure between 6 14 water column inches or 1 2 PSIG Has the proper gas regulator been installed for pressure and volume Have you installed the...

Page 17: ...garden hose to the cold water source Cold Water Source Garden Hose 98015100 10 STEP 6 Pull the spring loaded collar of the wand coupler back to insert pressure nozzle Release the coupler collar and p...

Page 18: ...ent Valve STEP 4 To apply detergent open the detergent valve counterclock wise making sure that the deter gent pick up tube is in the detergent solution and not sucking air 98015100 17 NOTE High press...

Page 19: ...thermal device prevents internal damage to the pump CLEANING TIPS Pre rinse cleaning surface with fresh water Place detergent suction tube directly into cleaning solu tion and apply to surface For be...

Page 20: ...syst me F Coupez l eau W ARNIN G PRE CAU CION AVE RTIS SEM ENT SK AL E NE BY ORS LEA EL MANUA L OPERA CION ANTES DE USARS E ESTE EQUIPO DEBE SER USADO SOLAM ENTE POR OPERA DORES CALIFIC ADOS LIRE LE M...

Page 21: ...metering valve Disassemble and clean thoroughly High viscosity of detergent Dilute detergent to specifications Restriction behind float tank screen removed Install restriction Hole in detergent line s...

Page 22: ...pair kit when needed Worn packing in pump Install new packing kit Fouled or dirty inlet or discharge valves in pump Clean inlet and discharge valve Worn inlet or discharge valves Replace with valve ki...

Page 23: ...1 Be sure main gas valve gas cock or selector arm is turned on 2 With gas on and system sparking probe terminals PV and 24V GND If pilot gas does not flow with 24 volts at these terminals replace gas...

Page 24: ...on With the pilot burning and the flame on the ignitor sensor rod the main burner should turn on If it does not replace the ignition control unit SHORT CYCLING OF MAIN BURNER MAIN BURNER TURNS OFF BE...

Page 25: ...needs repairing CAUTION When using this procedure to test compo nents keep the spray gun open at all times High Limit Hot Water Thermostat For safety each machine is equipped with a high limit control...

Page 26: ...d Exterior regulators are needed to control gas pressure Propane bottles are not included with the machine A pressure regulator should be installed between pro pane bottle and gas valve Propane Cylind...

Page 27: ...ugh the coil by whatever means are available for the particular system the water heater is used on To Adjust Pressure Regulator Adjustment of the pressure regulator is not normally necessary since it...

Page 28: ...per Gal Liquid 4 23 4 87 BTU per Cu Ft Vapor 2 563 3 39 BTU per Gal Liquid 91 547 102 032 BTU per Lb Liquid 21 591 21 221 Cu Ft per Lb Liquid 8 607 6 53 Cu Ft per Gal Liquid 36 45 31 8 Octane Number...

Page 29: ...ure gauge At the lower levels it is expressed in water column inches i e 11 w c i Higher pressures are expressed in terms of the force exerted against a square inch of area for example 125 lbs per squ...

Page 30: ...ife of your pressure washer Perform maintenance more often under severe conditions MAINTENANCE SCHEDULE Replace Fuel Lines Annually Pump Oil Inspect Daily inspect the oil level Change After first 50 h...

Page 31: ...nter field labor charges or freight damage WHAT YOU MUST DO TO OBTAIN WARRANTY SERVICE While not required for warranty service we request that you register your LANDA pressure washer by returning the...

Page 32: ...Form 9 801 511 0 Revised 9 13a Printed in U S A...

Reviews: