LANCOM 1722 VoIP – LANCOM 1724 VoIP
Chapter 5: Configuring Voice over IP
97
EN
After being adapted for international
and national
long distance,
the call routing table should appear as follows:
In this state, all calls that cannot be resolved by the call routing table and
which do not have a corresponding entry in the local user list are auto-
matically forwarded to the remote site.
If this is not desired, for example, where more than two sites are con-
nected in this way, an additional entry can detect only the internal calls to
a particular site. For this, make a new entry (for the number range '20' to
'29' at location B) in the call routing table
with the following values:
Called number / name: e.g. '2#' for all numbers that begin with a 2.
Number / name: The number called is remains unchanged and is used
as a destination number, i.e. here, also '2#'.
Line: Enter the SIP PBX line for the remote location here, i.e.
'LOCATION_B'.
In doing so, the standard route
is adjusted so that all numbers which
cannot be resolved are transmitted via ISDN.
After being adapted, the call routing table should appear as follows: