14. FLOW WASHER ASSEMBLY
14.1 REMOVAL
A. Remove cover and ID panel (see Cover and ID Panel, Section 8).
B. Remove valve from back block (see Valve, Section 9).
C. Remove nozzle/diffuser (see Nozzle/ Diffuser, Section 11).
D. Remove lever arm, if applicable (see Lever Arm, Section 10).
E. Remove four (4) screws holding the bottom plate in place.
F. Pull bottom plate off.
G. Pull the flow washer assembly out of its port, next to the nozzle mount on the underside of the
valve. The flow washer assembly will be one of the following:
Screw
Nozzle
Diffuser Assembly
Bottom Plate
Regulator Plug
(some models)
Flow Washer Assy
O-Ring
NOTE: Part Number in ( ) is a Coca-Cola PN
Thread Flowmeter wires though
O-Ring
05-2053/01
54-0176/04
(24245)
02-0005
(10050)
04-0633/01
(24209)
05-0960/01
(24244)
54-0192 (Red)
(24237)
Flow Washer Assy
54-0193 (White)
(24238)
Flow Washer Assy
54-0194 (Gray)
(24239)
05-0779/01
(24236)
02-0003
(10049)
Valve Body at this point.
(24246)
1. Gray, 3.0 ounce/sec product flow.
2. White, 2.25 ounce/sec product flow.
3. Red, 1.5 ounce/sec product flow.
14.2 INSTALLATION
A. Install o-rings, if necessary.
B. Apply 111 Lubricant to the o-rings, if necessary.
C. Install the appropriate flow washer assembly
into the keyed port on the underside of the
valve body.
NOTE:
The flow washer has a flat side and a
concave side. The flow washer must be installed
with the concave side facing the small diameter
hole in the flow washer retainer.
D. Place the flowmeter wires around the outside of
the flow washer mounting port, so that they will
not interfere with the bottom plate installation.
E. Line up holes on the bottom plate with the
screw holes on the underside of the valve body.
The raised sections around the screw holes
should fit completely in the counterbores on the
bottom plate.
FIGURE 18 - FLOW WASHER/SYRUP PLUG ACCESS
!
CAUTION
DO NOT PINCH ANY WIRES DURING INSTALL
PRECAUCIÓN
NO NO PELLIZQUE NINGÚN CABLE
DURANTE LA INSTALACIÓN.
ATTENTION
VEILLER À NE COINCER AUCUN FIL LORS
DU MONTAGE.
F. Secure bottom plate in place with four (4)
screws.
G. Mount valve in back block.
H. Replace nozzle/diffuser and lever arm (if
applicable).
I. Install ID panel and cover.
15. SYRUP REGULATOR
15.1 REMOVAL
A. If the syrup regulator plug or its o-rings need to be replaced, remove the valve from the back
block and take off the bottom plate.
B. Pull the regulator plug from the regulator port near the back of the underside of the valve body.
NOTE:
There is nothing mounted inside the regulator port.
14