7.4 CALIBRATED CUP PORTION CONTROL PROGRAMMING
In this mode, the valve adds the volume from each programming step to the total drink size. When
activated, the valve dispenses the total drink, without pauses.
A. Simultaneously, press and hold the small and large buttons (see Figures 9 and 10) on the
portion control until the LED light in the center starts blinking, then release switches.
B. Place volume cup under nozzle of valve to be calibrated.
C. Press appropriate size switch and fill volume cup to a point just short of the calibration mark on
the volume cup. The LED will stay lighted constantly while programming an individual cup size.
D. Let foam settle, jog size switch until liquid reaches the calibration mark on the volume cup.
E. Press pour/stop button to end programming for selected cup size. LED will start blinking.
F. To program another cup size, repeat steps B through E, this section (above).
G. To exit the calibrated cup programming mode, press the pour/stop button when the LED is
blinking. If the LED is lighted constantly, press the pour/stop button once to end the cup size
program (LED starts blinking) and again to exit the program mode (LED off).
8. COVER AND ID PANEL
8.1 REMOVAL
A. ID panel: Slide ID panel up until it detaches from cover.
!
CAUTION
PULL CAREFULLY, IF WIRES FOR A PUSHBUTTON OR PORTION CONTROL ARE ATTACHED.
PRECAUCIÓN
TIRE CUIDADOSAMENTE SI ESTÁN ADHERIDOS LOS CABLES A UN BOTÓN DE EMPUJE O UN
CONTROL DE PORCIÓN.
ATTENTION
SI L’ENSEMBLE EST RELIÉ PAR FILS À UN BOUTON-POUSSOIR DE COMMANDE OU À UNE
COMMANDE DE RÉGLAGE DE DÉBIT INDIVIDUEL, LE TIRER DÉLICATEMENT.
B. ID panel connector (If applicable): The circuit board connector on the Volumetric Valve has an
interlock feature that acts to keep an ID panel plug or Hand Held Programmer (HHP) plug
properly connected. The interlock feature consists of a recess in the circuit board connector
housing and a raised tab on the housing plug. See Figure 11, for the raised tab configuration.
When removing the connector, it is important to hold the housing and not the wires. The
housing easily slides out of the circuit board connector by placing a very slight downward
pressure onto the housing as it is removed (see Figure 12).
NOTE:
Pulling straight out while holding onto the wires is not recommended and will likely cause
damage to the valve, ID panel and/or HHP cable.
C. Cover: Loosen, but do not remove, cover screw. Pull cover straight up, until it is clear of the
valve body.
NOTE:
Push Button ID panel or lever must be connected to run “Syrup Pour” test from dip
switches. Push Button ID panel or lever must be disconnected to use the hand held programmer.
Raised Tab,
Housing Plug
PUSH
Slight downward pressure here,
while pulling housing straight out
FIGURE 11
FIGURE 12