INSTALLATION

Unpack the Dispenser

1.  Cut band and remove.

2.  Remove unit, with plywood shipping base, from packaging.
3.  Remove plywood shipping base from unit.

 

If unit is to be transported, it is advisable to leave the 

unit secured to the plywood shipping base.

 

NOTE

 

Inspect unit for concealed damage. If evident, notify 

 

delivering carrier and file a claim against the same.

NOTE

4.  If leg kit has been provided, assembly legs to unit by tilting 

unit to one side.

Drain Spider:

The drain spider is located to the left side near the front of the 

bin. The coldplate has a cavity designed to hold the drain spider. 

During shipment or installation, the drain spider may become  

dislodged from its original position. Prior to installing the  

dispenser, ensure the drain spider is in the correct position. This 

will prevent drain clog issues. Inspect the lower bin area to  

ensure the drain spider is secure in the coldplate cutout. If the 

drain spider is not in place, locate the drain spider and reinstall in 

the cavity where drain line exists.

Selecting/Preparing Counter Location

1.  Connecting lines can be run through the front of the unit and 

can extend down through a counter cutout. 

2.  Select a level, well ventilated, accessible location away from 

direct sunlight (avoid) or overhead lighting, within five (5) feet 

(1.5 m) of a drain, and a water supply that meets the  

requirements shown in the Specifications section found on 

previous page. 

3.  Select a location for the syrup pumps, CO

2

 tank, syrup  

containers, and water filter (recommended).

4.  The selected location should be able to support the weight of 

the unit with the ice after counter cut out is made (if  

applicable).

Leveling the Dispenser:

In order to facilitate proper dispenser drainage, ensure that the 

dispenser is level, front to back and side to side. Place a level on 

the top of the rear edge of the dispenser. The bubble must settle 

between the level lines. Repeat this procedure for the remaining 

three sides. Level unit if necessary. For optimum performance 

place the unit at a 0° tilt.

 

Your Service Agent:

 

Service Agent Telephone Number: 

 

Serial Number:

 

Model Number:

This manual was developed by the Lancer Corporation as a reference for the owner/operator and installer of this 

dispenser. Please read this guide before installation and operation of this dispenser. If service is required please call your 

Lancer Service Agent or Lancer Customer Service. Always have your model and serial number available when you call. 

READ THIS MANUAL

 

The installation, and relocation if necessary, must 

be carried out by qualified personnel with up-to-date 

knowledge and practical experience, in accordance with 

current regulations.

NOTE

 

NSF listed units must be sealed to the counter or have 

four (4) inch legs installed.

NOTE

Installation of Unit

2.  Remove Top Cover.
3.  Remove the two (2) valves from ice bin. 
4.  Install valves onto mounting blocks at front of dispenser. 

Push wire retainer down. This will lock valve to mounting 

block.

1.  The dispenser is designed to be installed either                

permanently to counter or placed on a counter using the four 

(4) inch legs (included in the Lancer kit, PN 82-1704)

Summary of Contents for Spartan Ice

Page 1: ...le damage If damage exists have the carrier note the damage on the freight bill and file a claim with carrier Responsibility for damage to the dispenser lies with the carrier The installation and relo...

Page 2: ...345 MPA with the provided pressure regulator Use a filter in the water line to avoid equipment damage and beverage off taste Check the water filter periodically as required by local conditions The wat...

Page 3: ...umps CO2 tank syrup containers and water filter recommended 4 The selected location should be able to support the weight of the unit with the ice after counter cut out is made if applicable Leveling t...

Page 4: ...sed in this unit may not be potable and should not be ingested Do not eat chew suck swallow or put into drinks The ice used in this unit is intended solely for the refrigeration purposes of the produc...

Page 5: ...a minimum of five gallons of cleaning solution Do not use abrasive cleaners or solvents because they can cause permanent damage to the unit Ensure rinsing is thorough using clean potable water at a te...

Page 6: ...solution from the dispenser 11 Taste the drink to verify that there is no off taste If off taste is found flush syrup system again Following sanitization rinse with end use product until there is no a...

Page 7: ...8 Item Part No Description 01 30 11833 Metal Lid 02 05 3240 01 Valve Cover EcoPour 03 19 71110 EcoPour Self Serve Valve 1 5 oz 04 05 3241 01 ID Panel EcoPour 05 30 11859 Cup Rest 06 05 3266 Drip Tray...

Page 8: ...Lancer Corp 800 729 1500 Technical Support Warranty 800 729 1550 custserv lancercorp com lancercorp com...

Reviews: