S4E V2 Hi-Carb Superchiller
220V / 60Hz
www.lancerbeverage.com
Page 10 of 27
Hoshizaki Lancer reserve the right to change specifications without notice
Part No: 68000006
Images are for illustration purposes only as product may vary.
012/4
– 23 April 2015
6.6
Connecting to water supply
Using appropriate tubing and fittings connect a 10mm water supply line from Superchiller
carbonator pump inlet tee to a filtered, regulated water supply. (See Postmix circuit diagram
page 13). Installation in accordance with AS/NZS 3500.1 and AS/NZS 3500.2.
Turn on water supply, check for leaks, adjust water regulator to 172-275kpa.
Open the carbonator relief valve until water flows from CO2 exhaust tube; then close the relief
valve.
Warning
The water inlet has to be supplied through a water tap that is
installed in accordance with plumbing rules and regulations.
Caution
Maximum water supply pressure to be 275 kpa.
Normal operating water temperature should be within 7°C to
35°C.
6.7
Connecting to CO2 supply
Warning
As carbon dioxide (CO2) displaces oxygen; prevention of CO2
leaks is paramount. If a leak is suspected, immediately ventilate
the contaminated area, before attempting repairs.
Connect CO
2
supply line from regulator to gas inlet on carbonator. (See Postmix circuit diagram
page 13 for details)
Adjust CO
2
Regulator supplying Carbonator to 550 kpa.
Turn on CO
2
supply.
6.8
Filling unit with water
Remove Superchiller lid and fill water bath until water flows out overflow tube.
NOTE:
Do not use water supplied from newly installed carbon filter as ice bank control operation will
be adversely affected.
6.9
Electrical Connection
This unit is connected to the supply via a 10 amp flexible cord fitted with a 3 pin plug.
Check the name plate on the machine for electrical supply requirements. Use only the power
supply specified on the name plate.
Warning
If the supply cord is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualified persons in
order to avoid a hazard.