background image

11

TROUBLE

CAUSE

REMEDY

Noisy carbonator pump.

1.  Insufficient water supply or water leak, 

allowing air to be pulled into pump.

2.  Loose pump coupling.

1.  Provide adequate water supply. Check 

strainer for cleanliness.

2.  Tighten set screw on pump coupling.

Off-taste in soda.

1.  Leaking water check valve, allowing  

carbonated water back into supply line.

1.  Dismantle and clean check valve. Replace 

O-ring if torn or distorted.

Valves inoperable.

1.  Loss of power.

1.  Check power supply to see if plugged in. 

Check transformer circuit breaker. Check 

main power circuit breaker 110V.

Post-Mix Troubleshooting

TROUBLE

CAUSE

REMEDY

BIB pump does not operate when 

dispensing valve opened.

1.  Out of CO

2

, CO

2

 not turned on, or low CO

2

 

pressure.

2.  Out of syrup.
3.  BIB connector not tight.
4.  Kinks in syrup or gas lines.
5.  Bad BIB Pumps.

1.  Replace CO

2

 supply, turn on CO

2

          

supply, or adjust CO

2

 pressure to 70-80 Psi 

(0.483-0.552 MPa)

2.  Replace syrup supply.
3.  Fasten connector tightly.
4.  Straighten or replace lines.
5.  Replace BIB pump.

BIB pump operated, but no flow.

1.  Leak in syrup inlet or outlet line.
2.  Defective BIB pump check valve.

1.  Replace line.
2.  Replace BIB pump

BIB pump continues to operate 

when bag is empty.

1.  Leak in suction line.
2.  Leaking o-ring on pump inlet fitting.

1.  Replace line.
2.  Replace o-ring.

BIB pump fails to restart after bag 

replacement.

1.  BIB connector not on tight.
2.  BIB connector is stopped up.
3.  Kinks in syrup line
4.  Bad BIB Pumps.

1.  Tighten BIB connector.
2.  Clean out or replace BIB connector.
3.  Straighten or replace line.
4.  Replace BIB pump.

BIB pump fails to restart when 

dispensing valve is closed.

1.  Leak in discharge line or fittings.
2.  Empty BIB.
3.  Air leak on inlet line or bag connector.

1.  Repair or replace discharge
2.  Replace BIB.
3.  Repair or replace.

Low or no carbonation.

1.  Low or no CO

2

.

2.  Excessive water pressure.
3.  Worn or defective carbonator pump.
4.  PCB malfunctioning.

1.  Check CO

2

 supply. Adjust CO

2

 pressure to 

70 Psi (0.483 MPa).

2.  Water regulator should be set at 50 Psi 

(0.345 MPa)

3.  Replace carbonator pump.
4.  See page 19.

To prevent possible harm to the environment from improper disposal, recycle the unit by  

locating an authorized recycler or contact the retailer where the product was purchased.  

Comply with local regulations regarding disposal of the refrigerant and insulation.

Dispenser Disposal

Summary of Contents for Multi-Valve Unit Tower

Page 1: ...for the unit being installed is required or needed please refer to the Lancer web site lancercorp com for immediate access or for your convenience scan this QR code with a mobile device app required...

Page 2: ...25 inches 184 15 mm Depth 9 inches 228 6 mm Height 16 5 inches 419 mm WEIGHT Shipping 15 lbs 7 0 kg CARBON DIOXIDE CO2 SUPPLY Min Pressure 70 PSIG 0 483 MPA Max Pressure 80 PSIG 0 552 MPA FITTINGS Pl...

Page 3: ...inage ensure that the dispenser is level front to back and side to side Place a level on the top of the rear edge of the dispenser The bubble must settle between the level lines Repeat this procedure...

Page 4: ...URN ON CO2 SUPPLY AT THIS TIME WARNING 7 Repeat Step 6 for both low pressure CO2 regulators on the regulator manifold routed to the unit and the syrup pumps A CO2 Regulator B Screwdriver C Regulator A...

Page 5: ...turning on CO2 7 Turn on CO2 at the source then using a screwdriver adjust the high pressure regulator at the source to 110 PSI 0 758 MPA then tighten locknut with wrench MULTI VALVE UNIT MVU PROGRAMM...

Page 6: ...positions B C D E and F 5 Press the Pour Cancel to save the changes and exit the programming mode Set MVU for Flavor Shots Refer to Overview Illustration for touch pad reference NOTE The Shot button w...

Page 7: ...press a brand button 5 Press the brand button again to pour for 4 seconds 6 Check for 10 oz of water in the ratio cup 7 Repeat process for other water type 8 Press Pour Cancel to exit programming mod...

Page 8: ...d for shot mode the LED light on that brand will blink twice and turn off NOTE The XL LED will blink slowly to indicate that it has been programmed The other size buttons are automatically set and do...

Page 9: ...p lines with BIB connectors in a bucket of warm water 3 Activate each valve to fill the lines with warm water and flush out syrup remaining in the lines 4 Prepare Cleaning Solution described on previo...

Page 10: ...ature too high 2 CO2 pressure too high 3 Water flow rate too high 4 Nozzle and diffuser not installed 5 Nozzle and diffuser not clean 6 Air in BIB lines 7 Poor quality ice 1 Correct prior to dispenser...

Page 11: ...or outlet line 2 Defective BIB pump check valve 1 Replace line 2 Replace BIB pump BIB pump continues to operate when bag is empty 1 Leak in suction line 2 Leaking o ring on pump inlet fitting 1 Replac...

Page 12: ...12 ILLUSTRATIONS PART LISTINGS MVU Tower Assembly...

Page 13: ...775 01 Retainer Slide 26 04 0481 Scr 8 32x1 125 27 64 5011 02 PCB Assy 28 49 0330 Nozzle Assy 49 0331 Nozzle Assy Flavor Shots Only 29 05 2687 01 Plate Nozzle 30 05 2682 Bracket Cover 31 54 0464 Cover...

Page 14: ...14 Wiring Diagram...

Page 15: ...15 Soda Water Flow Controls and Solenoids Plumbing Diagram...

Page 16: ...Lancer Corp 800 729 1500 Technical Support Warranty 800 729 1550 custserv lancercorp com lancercorp com...

Reviews: