WARNING

TO AVOID POSSIBLE PERSONAL INJURY OR PROPERTY DAMAGE, DO NOT ATTEMPT TO
REMOVE SYRUP TANK COVER UNTIL CO

2

PRESSURE HAS BEEN RELEASED FROM TANK.

D. Disconnect CO

2

supply hose from the water filled syrup tank.

E. Following the instructions as described in Section 2.1 above, mix appropriate amount of 

cleaning solution.  Fill a tank with this solution.  Connect hose half of syrup line to the tank.
Connect CO

2

supply hose to tank and pressurize.

F. Activate valve and draw cleaning solution through lines for a minimum of 60 seconds.  This will

ensure line is flushed and filled with cleaning solution.  Allow line to stand for at least 
30 minutes.

G. Disconnect CO

2

supply hose from the tank.

H. Connect hose half of syrup line to a tank filled with clean, potable, water at a temperature of 90°

to 110°F.  Connect CO

2

supply hose to tank and pressurize.

I.

Activate valve to flush and rinse line and fittings for a minimum of 60 seconds to remove all
traces of cleaning solution.  Continue rinsing until testing with phenolpthalein shows that the
rinse water is free of residual detergent.

WARNING

TO AVOID POSSIBLE PERSONAL INJURY OR PROPERTY DAMAGE, DO NOT ATTEMPT TO
REMOVE SYRUP TANK COVER UNTIL CO

2

PRESSURE HAS BEEN RELEASED FROM TANK.

J. Disconnect CO

2

supply hose from the tank.

K. Following the instructions as described in 2.1 above, mix appropriate amount of sanitizing 

solution.  Fill a tank with this solution.  Connect hose half of syrup line to the tank.  Connect CO

2

supply hose to tank and pressurize.

L. Activate valve and draw sanitizing solution through line for a minimum of 60 seconds.  This will

ensure line is flushed and filled with sanitizing solution.  Allow line to stand for at least 
30 minutes.

M. Disconnect CO

2

supply hose from the tank.

N. Reconnect syrup lines to syrup containers (for example, quick disconnects, figal containers, etc.)

and ready unit for operation.

O. Draw drinks to refill lines and flush the sanitizing solution from the dispenser.

NOTE

Please note that a fresh water rinse cannot follow sanitization of equipment.

Purge only with the

end use product until there is no after taste in the product.

P. Test dispenser in normal manner for proper operation.  Taste dispensed product to ensure there

is no off-taste.  If off-taste is found, additional flushing of syrup system may be required.

Q. Repeat cleaning, rinsing, and sanitizing procedures for each valve and each circuit.

2.4

CLEANING AND SANITIZING BEVERAGE COMPONENTS - BAG-IN-BOX SYSTEMS

NOTE

Extended lengths of product lines may require more time for flushing and rinsing lines than 
stated below.

A. Disconnect syrup quick disconnect coupling from syrup packages and connect coupling to a bag

valve removed from an empty Bag-in-Box (BIB) package.

B. Place syrup inlet line in a clean container filled with clean, potable, room temperature water.
C. Activate valve until water is dispensed.  Flush and rinse line and fittings for a minimum of 

60 seconds to remove all traces of residual product.

D. Following the instructions as described in 2.1 above, mix appropriate amount of cleaning 

solution in a clean container.  Place syrup inlet line in container filled with cleaning solution.

E. Activate valve and draw cleaning solution through lines for a minimum of 60 seconds.  This will

ensure line is flushed and filled with cleaning solution.  Allow line to stand for at least 30 minutes.

F. Place syrup inlet line in a clean container filled with clean, potable, water at a temperature of 90

°

to 110

°

F.

G. Activate valve to flush and rinse line and fittings for a minimum of 60 seconds to remove all traces

5

Summary of Contents for MB-18

Page 1: ...ounds 240 kg Operating 800 pounds 363 kg ELECTRICAL Operating Voltage 115 Hertz 60 Amps 20 This initial draft issue is released for field test purposes ONLY DATE 06 18 01 P N 28 0466 6655 LANCER BLVD...

Page 2: ...PPLY ASSEMBLY 10 i MANUFACTURERS INTRODUCTION High Volume Free Standing Fountain Drink Dispenser The unit is designed with the highest quality components to be user and service friendly Most set up pa...

Page 3: ...ater supply must be protected by means of an air gap a backflow prevention device located upstream of the CO2 injection system or another approved method to comply with NSF standards A backflow preven...

Page 4: ...ng ground convenience outlet having the same configuration as the power cord B Outlet must have proper voltage cycles and ampere ratings See Dispenser Name Plate for ratings NOTE Do not plug into elec...

Page 5: ...E Extended lengths of product lines may require that an additional volume of cleaning solution be prepared 2 Sanitizing solutions should be prepared in accordance with the manufacturer s written recom...

Page 6: ...Take care to carefully lift the tower shroud out of the way of the auger tube 4 Remove the auger tube in a similar fashion by lifting it straight up and out of the bin g Remove the Agitator Wheel Ass...

Page 7: ...at least 30 minutes M Disconnect CO2 supply hose from the tank N Reconnect syrup lines to syrup containers for example quick disconnects figal containers etc and ready unit for operation O Draw drink...

Page 8: ...d select keypad on the left hand side of machine ice speed defaults to middle selection if not otherwise selected Selection light will indicate choice C Fill cup with desired amount of ice D Place cup...

Page 9: ...stment STIR is for the auger stir speed and is also requires a setting of 1 through 10 b AUGER SWITCH MENU The auger switch menu selects whether the cup lever or the push buttons initiate ice dispensi...

Page 10: ...se is kinked B Replace Drain Hose Light Emitting Diodes LEDs are provided on the PC Board to aid in troubleshooting electrical difficulties Referring to the wiring diagram included in this manual also...

Page 11: ...375 2 MOUNT BRKT TO MOTOR ICE CHUTE ASSEMBLY 05 0925 CHUTE IBD 1 54 0191 TUBE PRINTED IBD 1 05 0999 LEVER CHUTE IBD 1 05 1488 RESTRICTOR CHUTE IBD 1 12 0244 SWITCH CHUTE 1 04 0268 SCREW 6 19 X 625 1 H...

Page 12: ...Y SYRUP J3 1 VALVES 33 THRU 39 52 2383 WIRE ASSY RIBBON 2 INTERCONNECT TO CPU 52 2384 WIRE ASSY POWER SUPPLY 1 POWER TO CPU 52 2385 WIRE ASSY ICE DISPENSE 1 ICE CHUTE SWITCH TO INTERCONNECT 52 2386 WI...

Reviews: