11
A
B
C
A. Syrup Separator
B. Nozzle
C. Soda Lever
3. Remove nozzle by twisting counter clockwise and pulling
down, then remove diffuser by pulling down.
4.
Install Lancer (yellow) syrup separator
(PN 54-0031)
in place
of nozzle.
6.
Activate valve to purge syrup until steady flow is achieved.
7. Using a Lancer brix cup, activate the valve and capture a
sample. Verify that the syrup level is even with the water
level. Use a screwdriver to adjust if needed.
8. Repeat process for each valve.
9. Re-install the merchandiser, splash plate, cup rest, and drip
tray then reattach bonnet using the top bonnet screw.
A
B
C
A. Syrup Separator
B. Brix Cup
C. Verify Soda/
Water Level
5.
Re-open syrup shut-off at mounting block.
Volumetric Valve Adjustment
If the programmer does not run its diagnostic test
properly, disconnect it and try plugging it in again. If
the programmer still fails, replace the programmer
NOTE
- Handheld Programmer
Volumetric Valve
1.
Remove the ID panel from the front of the first valve.
2. Insert the programmer’s 10-pin connector into the ID panel
plug located on the front of the circuit board.
3. When properly connected, the programmer will run a self
diagnostic test. The display will show all “8’s” with the
decimal points lighted. After about three (3) seconds, the
display indicates the setting of the dip switches.
4.
After the programmer is connected, Press the “Read Mem”
button.
5. Press the “Ratio +” or the “Ratio -” key until the desired ratio
is displayed.
6. Verify the drink type by pressing “Carb Toggle” to select “C”
for carbonated or “n” for non-carbonated.
7. Press the “Enter” button to program the valve with the setting
on the display.
8. Verify Ratio by pressing “Read Mem”.
9.
Disconnect the programmer and repeat steps 4-9 for each
valve.