5
Pre-Installation Checklist
POST MIX ACCESSORIES:
CO
2
Regulator
CO
2
Supply
Chain for CO
2
Tank
Beverage Dispenser
Beverage Tubing
Oetiker Clamp Fittings
Water Booster (Lancer PN:
82-3401 or MC-163172
CONSIDER THE FOLLOWING
BEFORE INSTALLATION:
Location of Water Supply Lines
Location of Drain
Location of Electrical Outlet
Location of Heating and Air
Conditioning Ducts
Do you have enough space to
install the dispenser?
Does the counter height meet
ADA requirements?
Is countertop level?
Can the countertop support the
weight of the dispenser? (Include
the weight of an ice machine plus
weight of ice, if necessary)
Is dispenser located away from
direct sunlight or overhead
lighting?
TOOLS REQUIRED:
Oetiker Pliers
Tubing Cutters
Wrench
Slotted Screwdriver
Phillips Screwdriver
Drill
BIB SYSTEM:
BIB Rack
BIB Syrup Boxes
BIB Regulator Set
BIB Connectors
General System Overview - Remote Syrup Pumps
75
A. Water Source
B. Water Filter
C. CO
2
Source
D. High Pressure CO
2
Regulator
E. Electrical Outlet
F. Counter
G. Tower (Dispenser)
H. Syrup Pump
I. BIB Syrup Containers
J. Floor Drain
A
B
C
D
E
G
F
H
J
H
H
H
I
I
I
I
Syrup Line
CO
2
Line
Electrical
Drain Line
Plain Water Line
Summary of Contents for Barrilitos Beverage Tower