12
Following sanitization, rinse with end-use product
until there is no aftertaste. Do not use a fresh water
rinse. This is a NSF requirement. Residual sanitizing
solution left in the system creates a health hazard.
!
CAUTION
Cleaning and Sanitizing Nozzle
1. Disconnect power, so as to not activate valve while clean-
ing.
2.
Remove outer nozzle by twisting clockwise and pulling
down.
3.
Rinse nozzle with warm water.
4. Thoroughly wash the nozzle using a clean soft cloth and
cleaning solution described on previous page.
5.
Using the nozzle brush (Lancer PN: 22-0017) included with
the unit and cleaning solution described on the previous
page, thoroughly clean the vent located on the nozzle.
A. Front Panel
B. Water/Syrup Valves
A
Scheduled Maintenance and Cleaning
As Needed
• Keep exterior surfaces of dispenser (include drip tray and cup rest) clean using a clean, damp
cloth.
Daily
•
Remove each nozzle and rinse well in warm water.
DO NOT
use soap or detergent. This will
cause foaming and off taste in finished product.
•
Using a soft cloth and cleaning solution, clean the nozzle injectors. See Cleaning and Sanitizing
Nozzle section on page 12 for reference.
• Remove cup rest and wash in warm soapy water.
• Pour warm soapy water into the drip tray and wipe with a clean cloth.
•
With a clean cloth and warm water, wipe off all of the unit’s exterior surfaces.
DO NOT USE
ABRASIVE SOAPS OR STRONG DETERGENTS.
•
Replace the cup rest and nozzle
Weekly
•
Taste each product for off tastes. If off taste occurs, clean and sanitize the unit using the
appropriate procedures outlined in the Cleaning and Sanitizing section of this manual.
Every Six Months
•
Clean and sanitize the unit using the appropriate procedures outlined in the Cleaning and
Sanitizing section of this manual.
6.
Immerse the nozzle in sanitizing solution and let sit for
fifteen (15) minutes.
7.
Set nozzle aside and let air dry.
DO NOT
rinse with water
after sanitizing.
8. Using a soft, clean cloth and cleaning solution, clean the
nozzle injectors.
9.
Using a soft, clean cloth, sanitize the nozzle injectors and
let air dry.
10.
Reconnect nozzle.
11. Connect power.
12.
Taste the drink to verify that there is no off-taste. If off-taste
is found, sanitize the nozzle and nozzle injectors again.
A. Nozzle Vent
A
Summary of Contents for Barrilitos Beverage Tower