lancer Barrilitos Beverage Tower Operation Manual Download Page 2

2

TABLE OF CONTENTS

BEFORE GETTING STARTED

Each unit is tested under operating conditions and is thoroughly 

inspected before shipment. At the time of shipment, the carrier 

accepts responsibility for the unit. Upon receiving the unit,  

carefully inspect the carton for visible damage. If damage exists, 

have the carrier note the damage on the freight bill and file a 

claim with carrier. Responsibility for damage to the dispenser 

lies with the carrier.

The installation and relocation, if necessary, of this product must be carried out by qualified personnel with 

 

up-to-date safety and hygiene knowledge and practical experience, in accordance with current regulations.

IMPORTANT SAFETY INSTRUCTIONS..........................3
 

Intended Use Warning................................................3

 CO

2

 Warning...............................................................3

 

Electrical Warning.......................................................3

 

Water Notice...............................................................3

PRE-INSTALLATION....................................................4-5
 

Specifications & Features...........................................4

 

General System Overview..........................................5

 

Pre-Installation Checklist............................................5

INSTALLATION.............................................................6-9

 

Unpacking the Dispenser...........................................6

 

Selecting/Preparing the Counter Location..................6

 

Dispenser Installation..............................................7-8

 

Adjust Water Flow Rate & Syrup/Water Ratio............8

MODES OF OPERATION...........................................9-10

 

Normal Operation Mode.............................................9

 

Technician Mode...................................................9-10

 

LED Saver Mode......................................................10

CLEANING & SANITIZING.......................................11-12

 

General Information..................................................11

 

Cleaning & Sanitizing Solutions................................11

 

Scheduled Maintenance & Cleaning...................11-12

 

Cleaning & Sanitizing Nozzle...................................12

 

Cleaning & Sanitizing Syrup Lines - BIB..................12

TROUBLESHOOTING..............................................13-15
ILLUSTRATIONS & PART LISTINGS.......................16-20
 

Main Unit Assembly..................................................16

 

Faucet Housing Assembly........................................17

 

Button Panel Assembly.............................................18

 

Wiring Diagram.........................................................19

 

DIP Switch Settings..................................................20

 

Plumbing Diagram....................................................21

SAFETY NOTICES

READ ALL SAFETY INSTRUCTIONS BEFORE USING THIS UNIT.

This manual contains important safety information and all applicable safety precautions must be observed. To reduce 

the risk of fire, electric shock, damage to the equipment or personal injury when using this unit all instructions/warnings 

on the product being used must be followed:

 

Text following the Warning signal indicates a            

hazardous situation, which if not avoided, will result 

in death or serious injury. Be sure to read all Warning 

statements before proceeding with the installation. 

WARNING

 

Text following the Caution signal indicates a             

hazardous situation, which if not avoided, could result 

in death or serious injury. Be sure to read the Caution 

statements before proceeding with the installation

CAUTION

 

Text following the Attention signal addresses a  

situation that if not followed could potentially damage 

the equipment. Be sure to read the Attention  

statements before proceeding

ATTENTION

 

Text following the Note signal provides you with  

information that may help you more effectively perform 

the installation procedures within this manual.  

Disregarding information will not cause damage or 

injury, however it may limit the performance of the 

dispenser. 

NOTE

ABOUT THIS MANUAL

This booklet is an integral and essential part of the product. 

Please carefully read the guidelines and warnings contained 

herein as they are intended to provide the user with essential 

information for the continued safe use and maintenance of the 

product. In addition, it provides 

GUIDANCE ONLY

 to the user 

on the correct services and site location of the unit.

Summary of Contents for Barrilitos Beverage Tower

Page 1: ...Lancer 2018 by Lancer all rights reserved 330 Lancer Corporation 6655 Lancer Blvd San Antonio Texas 78219 800 729 1500 Tech Support Warranty 800 729 1550 email custserv lancercorp com web lancercorp...

Page 2: ...Switch Settings 20 Plumbing Diagram 21 SAFETY NOTICES READ ALL SAFETY INSTRUCTIONS BEFORE USING THIS UNIT This manual contains important safety information and all applicable safety precautions must...

Page 3: ...e dispenser from the power source to service the unit Only qualified personnel should service internal components of electrical control housing WARNING Make sure that all water lines are tight and uni...

Page 4: ...ounces per second PLAIN WATER SUPPLY Min Flowing Pressure 25 psi 0 172 MPa Max Static Pressure 65 psi 0 448 MPa CARBON DIOXIDE CO2 SUPPLY Min Pressure 70 psi 0 483 MPa Max Pressure 80 psi 0 552 MPa FI...

Page 5: ...level Can the countertop support the weight of the dispenser Include the weight of an ice machine plus weight of ice if necessary Is dispenser located away from direct sunlight or overhead lighting T...

Page 6: ...and file a claim against the same NOTE Inspect the counter location where the unit is to be installed Verify the selected counter is strong enough to safely support the weight of the installed unit af...

Page 7: ...ust be sealed to the counter NOTE 8 Slide drip tray into opening in tower until magnets engage and lock drip tray in place The installation and relocation if necessary must be carried out by qualified...

Page 8: ...tray Adjust Water Flow Rate Syrup Water Ratio 1 Remove the front panel from the tower by pulling away from the unit and disengaging the magnets 2 Use the brand buttons to enter the Technician Mode see...

Page 9: ...r after 15 seconds Deselecting a Brand 1 The selected brands LED is ON and the light ring matches the color specified by the as sociated DIP switch configuration 2 Brand button is automatically desele...

Page 10: ...to cancel pour in progress Timed Pour of Syrup 1 The lever is in the OFF state and no brand is selected 2 Pull and release lever 5 times within a span of 5 seconds Pulls must be within 1 second of ea...

Page 11: ...rgent e g Sodium Laureth Sulfate dish soap with clean potable water at a temperature of 90 F to 110 F 32 C to 43 C The mixture ratio is one ounce of cleaner to two gallons of water Prepare a minimum o...

Page 12: ...ft cloth and cleaning solution clean the nozzle injectors See Cleaning and Sanitizing Nozzle section on page 12 for reference Remove cup rest and wash in warm soapy water Pour warm soapy water into th...

Page 13: ...1 O ring is damaged or missing 1 Replace o ring Miscellaneous leakage 1 Gap between parts 2 Damaged or improperly installed o rings 1 Tighten appropriate retaining screws 2 Replace or adjust appropri...

Page 14: ...f the dispenser 4 Check the CO2 pressure to the pump manifold to ensure it is between 70 and 80 psi 0 483 and 0 552 MPa 5 Check CO2 pressure and or replace pump 6 Remove kink or replace line Syrup onl...

Page 15: ...f CO2 CO2 not turned on or low CO2 pressure 2 Out of syrup 3 BIB connector not tight 4 Kinks in syrup or gas lines 5 Bad BIB Pumps 1 Replace CO2 supply turn on CO2 supply or adjust CO2 pressure to 70...

Page 16: ...06 01 2991 Coupling Female 07 82 5000 Drain Kit BBT 08 05 3719 01 Splash Plate BBT 09 82 5290 Faucet Housing Assy BBT 10 54 0557 Nozzle Assy BBT 11 19 0560 Valve Assy CVM Water 2 0 oz 12 19 0559 Valv...

Page 17: ...3756 Faucet Handle BBT 02 05 3757 Faucet Cam BBT 03 10 1019 Actuator Pin 04 04 0549 Screw 6 19 x 0 625 05 05 3765 Washer 06 05 3759 Upper Faucet Housing BBT 07 03 0530 Faucet Spring 08 82 5297 Actuat...

Page 18: ...18 Button Panel Assembly 01 x4 03 04 02 Item Part No Description 01 04 1639 01 Screw 4 20 x 0 250 02 52 3956 Buttons Harness BBT 03 05 3726 Button Panel BBT 04 82 5298 Button PCB Assembly...

Page 19: ...19 Wiring Diagram...

Page 20: ...ailable on the Barrilitos Tower NOTE DIP Switch Config Color Brand Name Mango Lime Switch 1 Default Position Pear Cucumber Switch 2 Default Position Pineapple Switch 3 Default Position Strawberry Hibi...

Page 21: ...S4 Syrup Line 4 PW Plain Water Line To prevent possible harm to the environment from improper disposal recycle the unit by locating an authorized recycler or contact the retailer where the product was...

Page 22: ...Lancer Corp 800 729 1500 Technical Support Warranty 800 729 1550 custserv lancercorp com lancercorp com...

Reviews: