D. Check/Adjust Ratios
1. To check and/or adjust the ratio you measure the amount of water dispensed and then the
finished product dispensed into a graduated cylinder. You adjust the finished product to
equal the volume of water dispensed.
2. Process
a. Turn key switch to flush mode.
b. Purge water line until clear by pressing pour cancel button.
c. Press the * and
#
buttons on outside edge of door panel at the same time to access the
RATIO MODE (see Figures 9 and 10).
5
Figure 9
HIDDEN RATIO
CHECK/ADJUST
BUTTONS
POUR / CANCEL
E. To check ratio:
1. Press and release pour cancel
a. Water will pour automatically (use a 500 ml graduated cylinder,
see Figures 11 and 12, to catch dispensed water - note level of
water for use in step G below).
b. 450 ML should pour into cylinder - Each band is 5 ml (if off more
that two bands, then troubleshoot water sub-system).
F.
Put cup under nozzle and press pour cancel. Throw first sample away.
G. Empty cylinder and place under nozzle assembly. Press and release
pour cancel.
1. Combined water and juice will dispense – Target is same as water
only level in step 1.
2. If within one band-width, return to operation.