4.
RELOCATING OR SHIPPING UNIT
4.1
REMOVING AN OPERATING UNIT
A. Remove concentrate packages (see Section 2.1).
B. Turn water supply OFF at the source. Activate one of the valves to drain the water from the
system.
C. Remove the splash plate. Slide the locking clip on the Shut Off Valve to release the inlet fitting
and remove the inlet fitting from the valve, leaving the valve connected to the unit.
D. Remove the water inlet line, either through the access plate in the rear of the unit or through the
bottom, depending on how the unit was installed.
WARNING
THIS UNIT MUST BE ELECTRICALLY GROUNDED TO AVOID POSSIBLE FATAL ELECTRICAL
SHOCK OR SERIOUS INJURY TO THE OPERATOR. THE POWER CORD IS PROVIDED WITH
A THREE PRONG GROUNDED PLUG. IF A THREE HOLE GROUNDED OUTLET IS NOT
AVAILABLE, USE AN APPROVED METHOD TO GROUND THE UNIT.
E. Turn the key switch OFF and disconnect the power cord from the electrical outlet.
F.
Attach a suitable length of drain tubing to the drain outlet.
G. Place the free end of the drain tubing in a suitable receptacle [i.e., a floor drain or a five (5)
gallon container] and rotate the barbed section counterclockwise approximately 2.5 turns. The
fitting has a hexagonal section at the base to facilitate rotation.
H. Turn the barbed end clockwise approximately 2.5 turns to close drain and remove drain tubing.
NOTE
The unit will have up to 10 pounds of ice attached to the Evaporator Coils. If unit is to be
shipped any distance, it is strongly recommended that the ice be removed.
The ice can easily be removed by refilling the unit with moderately hot water through the filling
tube on the compressor deck to melt the ice, and then draining the water from the unit.
4.2
TRANSPORTING UNIT
WARNING
DO NOT LAY UNIT ON ITS SIDE OR BACK.
The best method for transporting the unit is to secure it to a plywood shipping base.
4.3
SHIPPING UNIT
If a unit is to be shipped by common carrier, it must be secured to the plywood shipping base and
repacked in the original carton with the inner packing material. For this reason, it is wise to retain
the original shipping materials.
5.
REPAIR AND REPLACEMENT
5.1
LIGHTED FRONT DISPLAY
A. Turn unit to “Flush Mode” (key on right bottom side of dispenser) (see Figure 2).
B. Open dispenser door (press right # button on door panel to open door) (see Figure 3). Then lift
the door.
C. Turn the lens release handles on the lower part of the door liner one fourth (1/4) turn from the
“locked” position to the “open” position.
D. Lift front lens, graphic insert, and backing sheet out from the bottom edge of the lens, rotating
on the top edge until the locking tabs at the bottom clear the door shell, and the holding tabs on
the top edge can be disengaged from the door shell.
E. Place the graphic insert and backing sheet in the recess in the back of the door lens. Be sure
that these pieces are properly seated in the lens.
F.
Grasp the lens on the lower portion of both sides with the exterior surface of the lens closest to
your body, while keeping the graphic insert and backing plate properly seated with your
fingertips.
G. Insert the tabs on the top edge in their mating slots, and rotate the bottom edge until the
locking tabs are seated in the door (this operation is easier if the door is closed). Be sure that
10
Summary of Contents for 85-3322
Page 37: ...7 13 ASSEMBLED UNIT 34...