background image

®

ABOUT THIS MANUAL

This booklet is an integral and essential part of the product and 

should be handed over to the operator after the installation and 

preserved for any further consultation that may be necessary. 

Please read carefully the guidelines and warnings contained 

herein as they are intended to provide the user with essential 

information for the continued safe use and maintenance of the 

product. In addition, it provides 

GUIDANCE ONLY

 to the user on 

the correct services and site location of the unit.

BEFORE GETTING STARTED

Each unit is tested under operating conditions and is thoroughly 

inspected before shipment. At the time of shipment, the carrier 

accepts responsibility for the unit. Upon receiving the unit, 

carefully inspect the carton for visible damage. If damage exists, 

have the carrier note the damage on the freight bill and file a 

claim with carrier. Responsibility for damage to the dispenser lies 

with the carrier.

IMPORTANT SAFETY INSTRUCTIONS

The installation and relocation, if necessary, of this product must be carried out by qualified personnel with 

up-to-date safety and hygiene knowledge and practical experience, in accordance with current regulations.

The dispenser is for indoor use only. This appliance is to be installed in a location where its use can be overseen by trained 

personnel. This unit is not a toy. Children should be supervised not to play with appliance. It should not be used by children or 

infirm persons without supervision. This appliance is not intended for use by persons (including children) with reduced physical, 

sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction 

concerning use of the appliance by a person responsible for their safety. Cleaning and user maintenance shall not be performed by 

children without supervision. The min/max ambient operating temperature for the dispenser is 40°F to 105°F (4°C to 41°C). Do not 

operate unit below minimum ambient operation conditions. Should freezing occur, cease operation of the unit and contact 

authorized service technician. Service, cleaning and sanitizing should be accomplished only by trained personnel. Applicable safety 

precautions must be observed. Instruction warnings on the product being used must be followed.

Intended Use

Check the dispenser name plate label, located behind the splash plate, for the correct electrical requirements of unit.

 Do not plug 

into a wall electrical outlet unless the current shown on the serial number plate agrees with local current available. Follow all local 

electrical codes when making connections. Each dispenser must have a separate electrical circuit. Do not use extension cords with 

this unit. Do not ‘gang’ together with other electrical devices on the same outlet. The keyswitch does not disable the line voltage to 

the transformer primary. Always disconnect electrical power to the unit  to  prevent  personal injury before attempting any internal 

maintenance. The resettable breaker switch should not be used as a substitute for unplugging the dispenser from the power source 

to service the unit. Only qualified personnel should service internal components of electrical control housing. Make sure that all 

water lines are tight and units are dry before making any electrical connections!

Electrical Warning

FOR QUALIFIED INSTALLER ONLY.

 This basic Installation Sheet is an initial release. If a complete Operations 

Manual (for the unit being installed) is required or needed, please refer to the Lancer web site (lancercorp.com) for 

immediate access, or for your convenience, scan this QR code with a mobile device (app required) for immediate 

access to other Technical Documents and alternative translations (if available) pertaining to this unit. Contact Lancer 

Customer Service for assistance as required.

2500 Counter Electric Remote Chiller

LANCER INSTALLATION GUIDE

Lancer PN: 28-2821/01

Revision: November 2017

2500

•  WARNING:

 Carbon Dioxide (CO2) is a colorless, noncombustible gas with a light pungent odor. High percentages of CO

2

 may 

displace oxygen in the blood. 

•  WARNING: 

Prolonged exposure to CO

2

 can be harmful. Personnel exposed to high concentrations of CO

2

 gas will experience 

tremors which are followed by a loss of consciousness and suffocation. 

•  WARNING: 

If a CO

2

 gas leak is suspected, immediately ventilate the contaminated area before attempting to repair the leak. 

•  WARNING: 

Strict attention must be observed in the prevention of CO

2

 gas leaks in the entire CO

2

 and soft drink system.

Carbon Dioxide (CO

2

)

Summary of Contents for 2500 REMOTE series

Page 1: ...trained personnel Applicable safety precautions must be observed Instruction warnings on the product being used must be followed Intended Use Check the dispenser name plate label located behind the sp...

Page 2: ...TINGS Water from Carbonator Inlet 3 8 barb Plain Water Inlet 3 8 barb Brand Syrup Inlets 3 8 barb ELECTRICAL 230 240 VAC 50 60 Hz 2 6 Amps PLAIN WATER SUPPLY Min Flowing Pressure 25 PSI 0 172 MPA Max...

Page 3: ...lled water and stir 1 The unit is designed to sit on a flat supported surface capable of supporting a minimum weight of 400 lbs 182 kg Select a location that is in close proximity to a properly ground...

Page 4: ...ing to length between the pump CO2 inlets then connect tubing to all pumps Installation to Dispenser 1 Determine the appropriate length of insulated python tubing required allowing additional length a...

Page 5: ...k CO2 inlet 2 Using tubing cutters cut line from CO2 inlet to figal syrup tank and install tee fitting then route appropriate tubing from second figal syrup CO2 inlet to tee fitting 3 Repeat step 2 fo...

Page 6: ...it 15 Re attach bonnet and front plate 16 Activate each valve until a steady flow of carbonated water is achieved DO NOT TURN ON CO2 SUPPLY AT THIS TIME WARNING A CO2 Regulator B Screwdriver C Loosene...

Page 7: ...ype and concentration of sanitizing agent recommended in the instructions by the manufacturer shall comply with 40 CFR 180 940 The solution must provide 100 parts per million PPM chlorine e g Sodium H...

Page 8: ...ard is functioning properly Remove tape and reconnect board If any non conformities are found the PCB must be replaced PN 52 1423 01 Terminal 3 to 4 There should be continuity Use a short copper wire...

Page 9: ...9 WIRING DIAGRAM WHITE 18 AWG COMP DECK OUTLET POWER CORD GND WHITE 18 AWG CARB OUTLET WHITE 18 AWG RECIRC OUTLET WHITE 18 AWG ON LIGHT RECIRC SWITCH WHITE 18 AWG CARB SWITCH BLACK 18 AWG...

Page 10: ...RB S1 S6 S5 S4 S3 S2 SODA OUT WATER OUT SODA RECIRC S1 S2 S3 S4 S5 S6 THERMO SODA W SODA S1 W S2 S3 S4 S5 S6 S6 S5 S4 S3 S2 S1 REFRIGERATION UNIT WATER IN CO2 IN OUT IN SYRUP OUT WATER IN RECIRC PUMP...

Page 11: ...11...

Page 12: ...Lancer Corp 800 729 1500 Technical Support Warranty 800 729 1550 custserv lancercorp com lancercorp com...

Reviews: