Leave 12 inches (305 mm) of extra tubing below the 

counter for servicing and moving the dispenser

NOTE

 

The length of the python must not exceed 25 feet (8 

meters) if built-in syrup pumps are being used.

NOTE

 

If plain water is not wanted, remove the barbed fitting 

and short extension fitting, can cap end of plain water 

line with cap from accessory kit.

NOTE

 

The individual barbed fittings for the lines can be 

 

removed for insertion into the python tubing by 

 

removing the “U” shaped retainer pin and pulling the 

fitting off of the syrup line.

NOTE

 

If plain water is not wanted, splice a stainless steel, 

reducing, barbed hose tee (PN 01-0527) in the 3/8 inch 

soda line. Use a separate 1/4 inch tube to complete the 

connection from the barbed tee to the tower manifold.

NOTE

 

DO NOT insulate connections at this time. Leave all 

 

connections exposed for inspection of leaks.

NOTE

14.  Turn on water supply and check for leaks
15.  Plug in the unit to a grounded electrical outlet then turn the 

unit on to begin building an ice bank.  

 

The dispenser must be properly electrically grounded 

 

to avoid serious injury or fatal electrical shock. The 

 

power cord has a three-prong grounded plug. If a 

 

three-hole grounded electrical outlet is not available, 

use an approved method to ground the unit. Follow all 

local electrical codes when making connections. Each 

 

dispenser must have a separate electrical circuit. Do 

 

not use extension cords. Do not connect multiple

 

electrical devices on the same outlet.

WARNING

13.  Route appropriate tubing from the syrup pump location to the 

CO

2

 inlet and connect tubing to CO

2

 inlet.  

Installing Remote Syrup Pumps

1.  Install BIB rack and remote pumps according to manufactur

-

ers’ instructions.

2.  Once pumps and BIB rack are installed, measure and cut 

tubing to length between the pump CO

2

 inlets, then connect 

tubing to all pumps.

Installation to Dispenser

1. 

Determine the appropriate length of insulated python tubing 

required, allowing additional length as required for servicing.

A

B

C

A. Syrup Pump

B. CO

2

 Line

C. Fitting

D. Oetiker Pliers

D

3.  Using tubing cutters, cut any pump CO

2

 supply line and 

install tee fitting, then route appropriate tubing from the CO

2

 

supply to the tee fitting at syrup pumps. 

A. Tee Fitting

B. Line to Syrup Pump

C. Fitting

D. Line to CO

2

 Supply

A

B

B

C

D

4.  Cut tubing from CO

2

 supply to tee fitting at syrup pumps and 

install another tee fitting.

5.  Attach line from dispenser CO

2

 inlet to tee fitting between 

syrup pumps and CO

2

 supply. 

6. 

Connect tubing from dispenser syrup inlet to the syrup pump 

outlet fitting. Repeat for each syrup line/pump. 

2.  Position one end of the python near remote unit. Using a 

sharp knife or razor, slit the python insulation back 18 inches 

(46 cm) and roll insulation back to expose individual tubes.

3. 

Slide the tube insulation (from the accessory kit) over one of 

the 3/8 inch soda lines in the python then connect line to the 

90° elbow on the inlet to the recirculating pump.

4.  Connect the other 3/8 inch soda line from the python to the 

return inlet on the front of the unit.

5.  Connect each of the 1/4 inch syrup/plain water lines to the 

syrup/plain water inlets on the front of the unit.

6.  Route the opposite end of the python to tower. Determine 

the length required and cut if necessary.

7.  Slit the python insulation back 12 inches (30 cm) and roll 

insulation back to expose individual tubes.

8.  Connect each of the lines from the python to the syrup, soda, 

and plain water fittings on the tower manifold.

 

Careful not to cut tubing bundle when slitting python 

insulation.

ATTENTION

 

Use a sharp knife, razor blade, or tube cutter to cut 

 

tubing. Tubing cut with a saw will result in plastic 

 

shavings, which will plug the flow controls in the 

 

dispensing valve.

ATTENTION

Summary of Contents for 2500 REMOTE series

Page 1: ...trained personnel Applicable safety precautions must be observed Instruction warnings on the product being used must be followed Intended Use Check the dispenser name plate label located behind the sp...

Page 2: ...TINGS Water from Carbonator Inlet 3 8 barb Plain Water Inlet 3 8 barb Brand Syrup Inlets 3 8 barb ELECTRICAL 230 240 VAC 50 60 Hz 2 6 Amps PLAIN WATER SUPPLY Min Flowing Pressure 25 PSI 0 172 MPA Max...

Page 3: ...lled water and stir 1 The unit is designed to sit on a flat supported surface capable of supporting a minimum weight of 400 lbs 182 kg Select a location that is in close proximity to a properly ground...

Page 4: ...ing to length between the pump CO2 inlets then connect tubing to all pumps Installation to Dispenser 1 Determine the appropriate length of insulated python tubing required allowing additional length a...

Page 5: ...k CO2 inlet 2 Using tubing cutters cut line from CO2 inlet to figal syrup tank and install tee fitting then route appropriate tubing from second figal syrup CO2 inlet to tee fitting 3 Repeat step 2 fo...

Page 6: ...it 15 Re attach bonnet and front plate 16 Activate each valve until a steady flow of carbonated water is achieved DO NOT TURN ON CO2 SUPPLY AT THIS TIME WARNING A CO2 Regulator B Screwdriver C Loosene...

Page 7: ...ype and concentration of sanitizing agent recommended in the instructions by the manufacturer shall comply with 40 CFR 180 940 The solution must provide 100 parts per million PPM chlorine e g Sodium H...

Page 8: ...ard is functioning properly Remove tape and reconnect board If any non conformities are found the PCB must be replaced PN 52 1423 01 Terminal 3 to 4 There should be continuity Use a short copper wire...

Page 9: ...9 WIRING DIAGRAM WHITE 18 AWG COMP DECK OUTLET POWER CORD GND WHITE 18 AWG CARB OUTLET WHITE 18 AWG RECIRC OUTLET WHITE 18 AWG ON LIGHT RECIRC SWITCH WHITE 18 AWG CARB SWITCH BLACK 18 AWG...

Page 10: ...RB S1 S6 S5 S4 S3 S2 SODA OUT WATER OUT SODA RECIRC S1 S2 S3 S4 S5 S6 THERMO SODA W SODA S1 W S2 S3 S4 S5 S6 S6 S5 S4 S3 S2 S1 REFRIGERATION UNIT WATER IN CO2 IN OUT IN SYRUP OUT WATER IN RECIRC PUMP...

Page 11: ...11...

Page 12: ...Lancer Corp 800 729 1500 Technical Support Warranty 800 729 1550 custserv lancercorp com lancercorp com...

Reviews: