Leave 12 inches (305 mm) of extra tubing below the
counter for servicing and moving the dispenser
NOTE
The length of the python must not exceed 25 feet (8
meters) if built-in syrup pumps are being used.
NOTE
If plain water is not wanted, remove the barbed fitting
and short extension fitting, can cap end of plain water
line with cap from accessory kit.
NOTE
The individual barbed fittings for the lines can be
removed for insertion into the python tubing by
removing the “U” shaped retainer pin and pulling the
fitting off of the syrup line.
NOTE
If plain water is not wanted, splice a stainless steel,
reducing, barbed hose tee (PN 01-0527) in the 3/8 inch
soda line. Use a separate 1/4 inch tube to complete the
connection from the barbed tee to the tower manifold.
NOTE
DO NOT insulate connections at this time. Leave all
connections exposed for inspection of leaks.
NOTE
14. Turn on water supply and check for leaks
15. Plug in the unit to a grounded electrical outlet then turn the
unit on to begin building an ice bank.
The dispenser must be properly electrically grounded
to avoid serious injury or fatal electrical shock. The
power cord has a three-prong grounded plug. If a
three-hole grounded electrical outlet is not available,
use an approved method to ground the unit. Follow all
local electrical codes when making connections. Each
dispenser must have a separate electrical circuit. Do
not use extension cords. Do not connect multiple
electrical devices on the same outlet.
!
WARNING
13. Route appropriate tubing from the syrup pump location to the
CO
2
inlet and connect tubing to CO
2
inlet.
Installing Remote Syrup Pumps
1. Install BIB rack and remote pumps according to manufactur
-
ers’ instructions.
2. Once pumps and BIB rack are installed, measure and cut
tubing to length between the pump CO
2
inlets, then connect
tubing to all pumps.
Installation to Dispenser
1.
Determine the appropriate length of insulated python tubing
required, allowing additional length as required for servicing.
A
B
C
A. Syrup Pump
B. CO
2
Line
C. Fitting
D. Oetiker Pliers
D
3. Using tubing cutters, cut any pump CO
2
supply line and
install tee fitting, then route appropriate tubing from the CO
2
supply to the tee fitting at syrup pumps.
A. Tee Fitting
B. Line to Syrup Pump
C. Fitting
D. Line to CO
2
Supply
A
B
B
C
D
4. Cut tubing from CO
2
supply to tee fitting at syrup pumps and
install another tee fitting.
5. Attach line from dispenser CO
2
inlet to tee fitting between
syrup pumps and CO
2
supply.
6.
Connect tubing from dispenser syrup inlet to the syrup pump
outlet fitting. Repeat for each syrup line/pump.
2. Position one end of the python near remote unit. Using a
sharp knife or razor, slit the python insulation back 18 inches
(46 cm) and roll insulation back to expose individual tubes.
3.
Slide the tube insulation (from the accessory kit) over one of
the 3/8 inch soda lines in the python then connect line to the
90° elbow on the inlet to the recirculating pump.
4. Connect the other 3/8 inch soda line from the python to the
return inlet on the front of the unit.
5. Connect each of the 1/4 inch syrup/plain water lines to the
syrup/plain water inlets on the front of the unit.
6. Route the opposite end of the python to tower. Determine
the length required and cut if necessary.
7. Slit the python insulation back 12 inches (30 cm) and roll
insulation back to expose individual tubes.
8. Connect each of the lines from the python to the syrup, soda,
and plain water fittings on the tower manifold.
Careful not to cut tubing bundle when slitting python
insulation.
!
ATTENTION
Use a sharp knife, razor blade, or tube cutter to cut
tubing. Tubing cut with a saw will result in plastic
shavings, which will plug the flow controls in the
dispensing valve.
!
ATTENTION