5
(PPM) available chlorine. A minimum of five (5) gallons of sanitizing solution should be
prepared. Any sanitizing solution may be used as long as it is prepared in accordance with the
manufacturer's written recommendations and safety guidelines, and provides 50 to 100 parts
per million (PPM) available chlorine. Sanitizing solution is to be purged from line(s) and
equipment by flushing with product only until there is no after taste.
Do not rinse with water.
NOTE
Please note that a fresh water rinse cannot follow sanitization of equipment. Purge only with
the end use product until there is no after taste in the product.
This is an NSF requirement, since
residual sanitizing solution left in the system could create health hazards.
Extended lengths of product lines may require that an additional volume of sanitizing solution
be prepared.
C. Other
1.
Clean cloth towels.
2.
Bucket.
3.
) - included with installation kit.
4.
Extra nozzle.
5.
Sanitary gloves.
2.3
DAILY CLEANING
A. Carefully remove the nozzle housings by turning counter-clockwise and pulling down from the
nozzle body.
B. Wash the nozzle housings in warm soapy water and rinse with clean warm water.
C. Wet a clean cloth in warm soapy water.
D. While the nozzle housing is removed, wipe down the perimeter and end of the nozzle body.
E. Fill a cup with clean warm water and rinse nozzle body.
F.
Make certain that the nozzle o-ring is not torn or otherwise damaged. If necessary, replace
damaged o-ring with LANCER PN
G. Wet the inner surface of the nozzle housing with water and reinstall the nozzle housing by
sliding it over the nozzle body and turning clockwise to lock in position.
2.4
ICE BIN CLEANING - START UP AND MONTHLY
A. Disconnect Dispenser from power source.
B. Remove Top Cover
C. Melt out any remaining ice from the bin.
D. Remove Splash Plate, Drip Tray and front and rear bin covers.
E. Remove Agitator Pin from Agitator Shaft. Slide Agitator Shaft rearward out of Motor Shaft and
pull out of rear Bearing to remove.
F.
Remove Dispensing Wheel from Motor Shaft by sliding rearward.
G. Remove Dispensing Wheel Shroud.
H. Using cleaning solution, described in Section 2.2, and a clean cloth or soft brush, clean all
removable parts, sides of Ice Bin, Ice Chute, and surface of aluminum casting.
I.
Using hot water, thoroughly rinse away the cleaning solution.
J.
Wearing sanitary gloves, soak a clean cloth towel in sanitizing solution, described in Section 2.2,
and wash all surfaces of removable parts, sides of Ice Bin, Ice Chute, and surface of aluminum
casting.
K. Wearing sanitary gloves, reassemble all removable parts.
L.
Fill unit with ice and replace Top Cover.
NOTE
Lancer does not recommend the use of shaved, flake, nugget, or pellet ice in dispensers not properly
equipped to do so.
M. Reconnect Dispenser to power source.