The control valve, fitting and/or bypass are designed to 

accommodate  minor  plumbing  misalignments  but  are 

not  designed  to  support  the  weight  of  a  system  or  the 

plumbing.
Do not use Vaseline, oils, other hydrocarbon lubricants or 

spray silicone anywhere. A silicone lubricant may be used 

on black o-rings but is not necessary. 

Avoid any type of 

lubricants, including silicone, on the clear lip seals.

The  nuts  and  caps  are  designed  to  be  unscrewed  or 

tightened  by  hand  or  with  the  special  plastic  wrench 

(V3193). If necessary, pliers can be used to unscrew the 

nut or cap. Do not use a pipe wrench to tighten or loosen 

nuts or caps. Do not place a screw driver in the slots on 

caps and/or tap with a hammer.
Do not use pipe dope or other sealants on threads. Use 

Teflon tape on the threaded inlet, outlet and drain fittings. 

Teflon tape is not necessary on the nut connection or caps 

because of o-rings seals.
After  completing  any  valve  maintenance  involving  the 

drive  assembly  or  the  drive  cap  assembly  and  pistons, 

unplug power source jack from the printed circuit board 
(black wire) and plug back in or press and hold 

NEXT

  

and 

REGEN

 buttons for 3 seconds. This resets the electronics 

and establishes the service piston position. The display 

should flash the software version and then reset the valve 

to the service position.
Solder  joints  near  the  drain  must  be  done  prior  to 

connecting the drain line flow control fitting. Leave at least 

6” between the drain line control fitting and solder joints 

when  soldering  pipes  that  are  connected  on  the  drain 

line control fitting. Failure to do this could cause interior 

damage to the drain line flow control fitting.
When  assembling  the  installation  fitting  package  (inlet 

and outlet), connect the fitting to the plumbing system first 

and then attach the nut, split ring and o-ring. Heat from 

soldering or solvent cements may damage the nut, split 

ring  or  o-ring.  Solder  joints  should  be  cool  and  solvent 

cements should be set before installing the nut, split ring 

and  o-ring. Avoid  getting  primer  and  solvent  cement  on 

any part of the o-ring, split rings, bypass valve or control 

valve.
Install grounding strap on metal pipes.

This water filter is not to be used for treating water 

that  is  microbiologically  unsafe  or  of  unknown 

quality without adequate disinfection before or after 

treatment.

GENERAL INSTALLATION 

AND SERVICE WARNINGS

PRE-INSTALLATION

REVIEW

WATER PRESSURE: 

A minimum of 20 pounds of water 

pressure  (psi)  is  required  for  backwash.  Maximum  100 

psi. CAUTION: the filter cannot be subject to a vacuum 

due to loss of pressure (such as a water main break or 

submersible well pump check valve failure).

WATER TEMPERATURE:

 The range of water temperature 

is 35°F to 100°F. DO NOT install any water filter with less 

than 10 feet of piping between its outlet and the inlet of a 

water heater. 

AMBIENT TEMPERATURE: 

DO NOT locate filter where it 

or its connections (including the drain and overflow lines) 

will ever be subject to room temperatures under 33°F.

ELECTRICITY:

 An uninterrupted 120 volt 60Hz source is 

required. 

Make  sure  electrical  source  is  not  on  a  timer 

or  switch.

 All  electrical  connections  must  be  connected 

according  to  local  codes. The  plug-in  transformer  is  for 

dry locations only. Surge protection is recommended with 

all electrical connections.

DRAIN:

 

All plumbing should be done in accordance with 

local  plumbing  codes.  The  distance  between  the  drain 

and the water filter should be as short as possible. The 

pipe size for the drain line should be a minimum of 1/2” 

(inside diameter of pipe). For backwash rates of 7 gpm or 

higher, use a 3/4” drain line.

FILTERING: 

It is recommended that the filter be installed 

to treat both the hot and cold water supply. Outside faucets 

should be left on untreated water.

BYPASS: 

A  bypass  valve  (optional  accessory)  should 

be installed so that water will be available if it should be 

necessary to shut off the pressure in order to service the 

filter.

Summary of Contents for XFACTOR 7-LX125F-DAN-1B

Page 1: ...documents ELECTRONIC WATER FILTER WITH THE 1 X FACTOR DIAMOND LINE CONTROL VALVE ESTATE SERIES INSTALLATION OPERATING AND SERVICE MANUAL WATER FILTERS AND NEUTRALIZERS ACID NEUTRALIZERS 7 LX125F DAN...

Page 2: ...structions for 7 LXCTAIR 7 LXIMAIR 7 Placing Filter into Service 8 General Operation 8 Set Time of Day 9 Adjust Days Between Backwash or Time of Backwash 9 10 Low Battery 10 Contact Screen Programming...

Page 3: ...damage the nut split ring or o ring Solder joints should be cool and solvent cements should be set before installing the nut split ring and o ring Avoid getting primer and solvent cement on any part...

Page 4: ...lass filled Noryl or equivalent and the nuts and caps are glass filled polypropylene All seals are self lubricating EPDM to help prevent valve seizing after long periods of non use Internal o rings ca...

Page 5: ...4 When assembling the installation fitting package inlet and outlet connect the fitting to the plumbing system first and then attach the nut split ring and o ring Heat from soldering or solvent cement...

Page 6: ...HOT LOCATE WATER FILTER CLOSE TO A DRAIN AVOID OVERHEAD DRAIN LINES IF POSSIBLE TO PREVENT BACK PRESSURE ON THE SYSTEM IF OVERHEAD DRAIN LINE IS USED AND EXCEEDS 5 FEET ABOVE CONNECTION ON CONTROL VAL...

Page 7: ...M BACKWASHES IF THIS IS OBJECTIONABLE A CHECK VALVE CAN BE INSTALLED DIRECTLY AFTER THE AERATION SYSTEM NOTE IF A CHECK VALVE IS INSTALLED BETWEEN A PRESSURE TANK AND A WATER HEATER A HOT WATER EXPANS...

Page 8: ...allows an air pocket to form for the filter to function properly Control will automatically advance to the FILTERING position Open the outlet valve of the filter or if using optional bypass place to N...

Page 9: ...and simultaneously for 3 seconds to access Installer Display Settings STEP 2 Day Override Set the maximum number of days between backwashes REGEN If value set to OFF backwash initiation is based solel...

Page 10: ...digit Banner Text Set the banner text up to a maximum of 44 characters Use the or to select letters of the alphabet numbers ampersand or a space in the banner text Press NEXT to forward to the next ch...

Page 11: ...sh down to fully seat Battery replacement is 3 volt lithium coin cell type 2032 Correct Battery Orientation 1 2 3 5 6 4 X FACTOR FRONT COVER AND DRIVE ASSEMBLY After completing any valve maintenance i...

Page 12: ...3 4 5 INJECTOR CAP INJECTOR SCREEN INJEECTOR PLUG AND O RING Drawing No Order No Description Qty 1 V3430 Spacer Stack Assembly 1 2 V3004 Drive Cap Assy 1 3 V3178LP Back Plate 1 4 V3407 Piston Downflo...

Page 13: ...or tightened by hand or with the service spanner wrench see page 16 If necessary a pliers can be used to unscrew the nut or cap Do not use a pipe wrench to tighten or loosen nuts or caps Do not place...

Page 14: ...dge Do not use pipe dope or other sealants on threads Teflon tape must be used on threads of 3 4 NPT connection unless using 5 8 polytubing Do not use Vaseline oils other hydrocarbon lubricants or spr...

Page 15: ...s on threads Teflon tape must be used on threads of 1 NPT connection Teflon tape is not necessary on the nut connection nor caps because of o ring seals The nut and caps are designed to be unscrewed o...

Page 16: ...tools are necessary to assemble or disassemble the valve the wrench shown in various positions on the valve may be purchased to aid in assembly or disassembly Loosens Injector And Bypass Caps Loosens...

Page 17: ...der No V3007 07 Description Fitting 1 1 PVC Solvent Assembly Drawing No Order No Description Quantity 1 V3151 Nut 1 Quick Connect 2 2 V3150 Split Ring 2 3 V3105 O Ring 215 2 4 V3352 Fitting 1 1 PVC So...

Page 18: ...l conditions Pressure drop is very low DRIVE ASSEMBLY refer to pages 11 12 for diagrams Remove the valve cover to access the drive assembly Disconnect the power source plug black wire from the PC boar...

Page 19: ...seals with an o ring To remove the drive cap assembly use the special plastic service spanner wrench see page 16 or insert a to flat blade screwdriver into one of the slots around the top 2 of the dr...

Page 20: ...iers if necessary Attached to the injector cap is a screen Remove the screen and clean if fouled The plug and or injector can be pried out with a small screwdriver The plug can be wiped clean If the p...

Page 21: ...lace meter f Defective PC Board f Replace PC Board 4 Control valve backwashes at wrong time of day a Power outage a Reset time of day If PC Board has battery back up present the battery may be deplete...

Page 22: ...tion or disconnect power supply from PC Board for 5 seconds and then reconnect b PC Board not properly snapped into drive bracket b Properly snap PC Board into drive bracket and then Press NEXT and RE...

Page 23: ...NEXT and REGEN buttons for 3 seconds to resynchronize software with piston position or disconnect power supply from PC Board for 5 seconds and then reconnect Then re program valve to proper setting b...

Page 24: ...PAGE 24 A DIVISION OF C B TOOL CO 1340 MANHEIM PIKE LANCASTER PA 17601 3196 TEL 717 397 3521 FAX 717 392 0266 www lancasterwatertreatment com E mail info lancasterpump com 11 16...

Reviews: