ASSEMBLY INSTRUCTIONS

STEP 1: TANK ASSEMBLY (SEE DIAGRAM ON PREVIOUS PAGE)

STEP 1B

Connect #3 to #2 on the bottom of Filter Housing #1. The threaded Drain Valve Assembly 
should be on the inlet side (right side) at the bottom of the tank. 

HAND TIGHTEN ONLY.

STEP 1A

Wrap #9 (Drain Valve Assembly) with three clockwise wraps of Teflon

®

 tape. Install/thread 

#9 (Drain Valve Assembly) into #3. 

HAND TIGHTEN ONLY.

STEP 1C

Connect #4 to #3; Flow Meter Assembly should be placed on the Outlet Side (left side) 
at the bottom of the tank. Connect #5 Bypass to #3.

 

HAND TIGHTEN ONLY.

STEP 1D

Connect #6 to #4 and #5.

 

HAND TIGHTEN ONLY.

STEP 1E

Use either part #7 or #8 for connecting your plumbing to the system. 

HAND TIGHTEN ONLY.

STEP 1G

Install 3-AAA batteries in umbrella 
cap; connect to power supply.

STEP 1F

Connect 3/8" PEX plumbing to Drain Valve Assembly #9

 

(NOT PROVIDED).

Summary of Contents for 7-CTFS-NSF

Page 1: ...SOLUTIONS This manual should be kept for future reference If you have any questions regarding your water filter contact your local dealer OEM or the manufacturer at the following Lancaster Water Group 1340 Manheim Pike Lancaster PA 17601 lancasterwatergroup com 1 800 442 0786 ...

Page 2: ...of your home to relieve water pressure by draining it from lines Installing Ground To maintain an electrical ground in metal plumbing of a home s cold water piping such as a copper plumbing system install a ground clamp or jumper wiring The system and installation must comply with state and local laws and regulations NOTES Plumbing the filtration system assembly the inlet and outlet of the filtrat...

Page 3: ... METERASSY 5 Meter Spacer Assembly CT METERSPACER 6 Bypass Manifold CT IOHMBK BYPASSMANIFOLD GR 7 1 MNPT Straight Connector CT 1MNPTSTRAIGHT 8 1 MNPT 90 Degree Elbow Connector CT 1MNPTELBOW 9 3 8 PEX Drain Valve Kit Assembly With Shut off CT 38DRAINVALVEKIT P 10 PCB Umbrella With Electronics Non WIFI Version 1 CT PCBUMBRELLA NONWIFI V1 NOT SHOWN IN DIAGRAM PART IDENTIFICATION PART NUMBER Head and ...

Page 4: ...f Teflon tape Install thread 9 Drain Valve Assembly into 3 HAND TIGHTEN ONLY STEP 1C Connect 4 to 3 Flow Meter Assembly should be placed on the Outlet Side left side at the bottom of the tank Connect 5 Bypass to 3 HAND TIGHTEN ONLY STEP 1D Connect 6 to 4 and 5 HAND TIGHTEN ONLY STEP 1E Use either part 7 or 8 for connecting your plumbing to the system HAND TIGHTEN ONLY STEP 1G Install 3 AAA batteri...

Page 5: ...o pull the cap out of the top of the tank STEP 4A Place the top cap back into its original location STEP 4B Reattach the snap ring then pull up on the cap to lock in the O rings STEP 4 REATTACH THE TOP CAP STEP 5B Slowly turn the water back on Press down on the red button located in the middle of the cap This depressurizes the system and relieves it of air Keep the button pressed down as the water...

Page 6: ...d should be reinstalled into the bottom connection for proper installation of filter 8 Open the fitting and shut off and then flush out the bottom of the system 9 Look down into the tank assembly and locate the small opening centered in the bottom of the tank 10 Remove packaging from the new filter and place the new cartridge into the tank with the double O ring facing down 11 Position the cartrid...

Page 7: ...place the filter in their E3 M system by following a few simple steps LED REPLACEMENT NOTIFICATIONS EASY TO UNDERSTAND LED REPLACEMENT NOTIFICATIONS EASY FILTER REPLACEMENTS WITH NO TOOLS REQUIRED 1 PRESS THE RED PRESSURE RELIEF VALVE TO UNSEAT THE RING 2 REMOVE SNAP RING 3 LIFT TOP CAP GREEN FILTER GOOD Meter preset at 100 000 gallons see page 6 for adjusting presets Three AAA batteries not inclu...

Page 8: ...ou have questions or concerns please contact Lancaster Water Group at 1 800 442 0786 90 Degree Elbow Connectors 2 Umbrella Cap Filter Cap Filter Housing Bypass Manifold In Out Head w Filter Adapter 2 5 Inlet Cap Vertical Elbows 2 Straight Connector Drain Valve Assembly Flow Meter Assembly ...

Page 9: ...filter are not necessarily in all users water WARNINGS Claims are not performance tested by IAPMO or NSF Performance claims are based on independent laboratory and manufacturer s internal test data Actual performance is dependent on influent water quality flow rates system design and application Results may vary This system conforms to NSF ANSI 53 for the specific performance claims verified and s...

Page 10: ...e wait 2 seconds and repeat Refer to the figures below for an example FIGURE 1 To change the maximum gallons setting press and hold the button for 1 second LED 1 should turn solid green LED 2 should turn off and LED 3 should flash green the number of times that corresponds to the current setting Pressing the button for less than 1 second would increment the value rolling over from 9 to 0 Figure 2 ...

Page 11: ...11 ...

Page 12: ...d or translated into another language without the prior written consent of LANCASTER WATER TREATMENT Copyright 2022 LANCASTER WATER TREATMENT All rights reserved POWERED BY Where Innovation Flows This form must be signed and dated by the buyer and seller prior to the consummation of this sale This form should be retained on file by the seller for a minimum of two years Buyer s Name printed Buyer s...

Reviews: