background image

5

INSTALLING THE CARTRIDGE

STEP 5C

Release the button, then check the system for leaks. Run water for 10 minutes through the system to make sure it’s fully flushed out.

STEP 5A

Allow enough time for glue to dry, if PVC glue fittings are used on initial system install, according to instructions provided 
by the manufacturer.

STEP 5: FINAL CHECK

STEP 2: REMOVING THE TOP CAP

STEP 2A

Unseat the snap ring by pushing down on the top cap with both hands. Remove the ring by taking 
the handle and pulling inward, then upward; the ring should slide completely out.

STEP 2B

Remove the snap ring on the top of the tank, then remove the top cap from the housing 
assembly. Lift up on the handles to pull the cap out of the top of the tank.

STEP 4A

Place the top cap back into 
its original location.

STEP 4B

Reattach the snap ring, then 
pull up on the cap to lock in  
the O-rings.

STEP 4: REATTACH THE TOP CAP

STEP 5B

Slowly turn the water back on. Press down on the red button located in the middle of the cap. This 
depressurizes the system and relieves it of air. Keep the button pressed down as the water comes  
back on. DO NOT stop pushing the button until all air pressure is released and water comes out of  
the depressurization button.

STEP 3: FILTER PREPARATION

STEP 3A

Remove the filter cartridge from the packaging, then place it into the tank with the O-ring down. 
Align the cartridge to the bottom center opening.

 (Note: There’s a small opening in the bottom 

center of the tank to help you align the cartridge.)

 Press down on the filter cartridge so the O-ring 

moves down into place.

Summary of Contents for 7-CTFS-NSF

Page 1: ...SOLUTIONS This manual should be kept for future reference If you have any questions regarding your water filter contact your local dealer OEM or the manufacturer at the following Lancaster Water Group 1340 Manheim Pike Lancaster PA 17601 lancasterwatergroup com 1 800 442 0786 ...

Page 2: ...of your home to relieve water pressure by draining it from lines Installing Ground To maintain an electrical ground in metal plumbing of a home s cold water piping such as a copper plumbing system install a ground clamp or jumper wiring The system and installation must comply with state and local laws and regulations NOTES Plumbing the filtration system assembly the inlet and outlet of the filtrat...

Page 3: ... METERASSY 5 Meter Spacer Assembly CT METERSPACER 6 Bypass Manifold CT IOHMBK BYPASSMANIFOLD GR 7 1 MNPT Straight Connector CT 1MNPTSTRAIGHT 8 1 MNPT 90 Degree Elbow Connector CT 1MNPTELBOW 9 3 8 PEX Drain Valve Kit Assembly With Shut off CT 38DRAINVALVEKIT P 10 PCB Umbrella With Electronics Non WIFI Version 1 CT PCBUMBRELLA NONWIFI V1 NOT SHOWN IN DIAGRAM PART IDENTIFICATION PART NUMBER Head and ...

Page 4: ...f Teflon tape Install thread 9 Drain Valve Assembly into 3 HAND TIGHTEN ONLY STEP 1C Connect 4 to 3 Flow Meter Assembly should be placed on the Outlet Side left side at the bottom of the tank Connect 5 Bypass to 3 HAND TIGHTEN ONLY STEP 1D Connect 6 to 4 and 5 HAND TIGHTEN ONLY STEP 1E Use either part 7 or 8 for connecting your plumbing to the system HAND TIGHTEN ONLY STEP 1G Install 3 AAA batteri...

Page 5: ...o pull the cap out of the top of the tank STEP 4A Place the top cap back into its original location STEP 4B Reattach the snap ring then pull up on the cap to lock in the O rings STEP 4 REATTACH THE TOP CAP STEP 5B Slowly turn the water back on Press down on the red button located in the middle of the cap This depressurizes the system and relieves it of air Keep the button pressed down as the water...

Page 6: ...d should be reinstalled into the bottom connection for proper installation of filter 8 Open the fitting and shut off and then flush out the bottom of the system 9 Look down into the tank assembly and locate the small opening centered in the bottom of the tank 10 Remove packaging from the new filter and place the new cartridge into the tank with the double O ring facing down 11 Position the cartrid...

Page 7: ...place the filter in their E3 M system by following a few simple steps LED REPLACEMENT NOTIFICATIONS EASY TO UNDERSTAND LED REPLACEMENT NOTIFICATIONS EASY FILTER REPLACEMENTS WITH NO TOOLS REQUIRED 1 PRESS THE RED PRESSURE RELIEF VALVE TO UNSEAT THE RING 2 REMOVE SNAP RING 3 LIFT TOP CAP GREEN FILTER GOOD Meter preset at 100 000 gallons see page 6 for adjusting presets Three AAA batteries not inclu...

Page 8: ...ou have questions or concerns please contact Lancaster Water Group at 1 800 442 0786 90 Degree Elbow Connectors 2 Umbrella Cap Filter Cap Filter Housing Bypass Manifold In Out Head w Filter Adapter 2 5 Inlet Cap Vertical Elbows 2 Straight Connector Drain Valve Assembly Flow Meter Assembly ...

Page 9: ...filter are not necessarily in all users water WARNINGS Claims are not performance tested by IAPMO or NSF Performance claims are based on independent laboratory and manufacturer s internal test data Actual performance is dependent on influent water quality flow rates system design and application Results may vary This system conforms to NSF ANSI 53 for the specific performance claims verified and s...

Page 10: ...e wait 2 seconds and repeat Refer to the figures below for an example FIGURE 1 To change the maximum gallons setting press and hold the button for 1 second LED 1 should turn solid green LED 2 should turn off and LED 3 should flash green the number of times that corresponds to the current setting Pressing the button for less than 1 second would increment the value rolling over from 9 to 0 Figure 2 ...

Page 11: ...11 ...

Page 12: ...d or translated into another language without the prior written consent of LANCASTER WATER TREATMENT Copyright 2022 LANCASTER WATER TREATMENT All rights reserved POWERED BY Where Innovation Flows This form must be signed and dated by the buyer and seller prior to the consummation of this sale This form should be retained on file by the seller for a minimum of two years Buyer s Name printed Buyer s...

Reviews: