6
UMBRELLA CAP
AND LED LIGHTS
1. Turn off the water supply to the system by shutting off the inlet and outlet valves on the bypass.
2.
(Optional)
Install a 3/8" PEX tubing hose to the provided fitting and shut-off that connects to the inlet side of the
filtration system. Run the hose to a floor drain or bucket, and use to drain sediment or to aid in filter removal during change-out.
3. Remove umbrella cap on the top of the vessel. Replace the 3-AAA batteries with new batteries. Push and hold the reset
button on the metered board for 3 seconds to reset the totalizer. When the totalizer is reset, the LED lights will flash green
3 times to confirm that it is reset.
4. Depressurize the system by pushing down on the red depressurization button on the top cap of the system. Keep the
button pushed down until all the air or water pressure is completely released.
5. Push down the top cap with both hands to unseat the retaining ring.
6. Remove the retaining ring by carefully grasping the handle and pulling inward, then upward. The retaining ring should slide
completely out of the groove.
7. Remove the top cap of the system by lifting up on the top handles and remove the old filter.
(NOTE that filter adapter
(yellow/white in color) may come loose from bottom connection when removing filter, and should be reinstalled into the
bottom connection for proper installation of filter.)
8. Open the fitting and shut-off, and then flush out the bottom of the system.
9. Look down into the tank assembly and locate the small opening centered in the bottom of the tank.
10. Remove packaging from the new filter and place the new cartridge into the tank with the double O-ring facing down.
11. Position the cartridge so that it is aligned with the bottom center opening.
12. Press down on the cartridge so that the double O-ring seal moves into place within the bottom center opening.
13. Reposition the top cap into its original location.
14. Reattach the top tank snap ring, then pull up on the top cap to seat O-rings.
15. (If Step 2 was completed, do this step; if not, skip to 16.)
Close the fitting and shut-off.
16. Turn the water supply on and open the inlet and outlet valves on the bypass.
17. Relieve the system of air in the tank as the system fills with water by pushing down on the red depressurization button on
the top cap of the system. Keep the button pushed down until all the air pressure is completely released, and water comes
out of the red depressurization button.
18. Release the red depressurization button.
19. Return the umbrella cap to the top of the system.
20. Check for leaks.
21. Flush the new cartridge per its installation instructions.
22. During flush, confirm green LED lights are flashing with flowing water. If lights are not flashing green, go back to step 3.
REPLACING THE CARTRIDGE