UMBRELLA CAP

AND LED LIGHTS

1.  Turn off the water supply to the system by shutting off the inlet and outlet valves on the bypass.

2.   

(Optional) 

Install a 3/8" PEX tubing hose to the provided fitting and shut-off that connects to the inlet side of the 

filtration system. Run the hose to a floor drain or bucket, and use to drain sediment or to aid in filter removal during change-out.

3.  Remove umbrella cap on the top of the vessel. Replace the 3-AAA batteries with new batteries. Push and hold the reset 

button on the metered board for 3 seconds to reset the totalizer. When the totalizer is reset, the LED lights will flash green  
3 times to confirm that it is reset.

4.  Depressurize the system by pushing down on the red depressurization button on the top cap of the system. Keep the 

button pushed down until all the air or water pressure is completely released.

5.  Push down the top cap with both hands to unseat the retaining ring.

6.  Remove the retaining ring by carefully grasping the handle and pulling inward, then upward. The retaining ring should slide 

completely out of the groove.

7.  Remove the top cap of the system by lifting up on the top handles and remove the old filter.

 (NOTE that filter adapter 

(yellow/white in color) may come loose from bottom connection when removing filter, and should be reinstalled into the  
bottom connection for proper installation of filter.)

8.  Open the fitting and shut-off, and then flush out the bottom of the system.

9.  Look down into the tank assembly and locate the small opening centered in the bottom of the tank.

10.  Remove packaging from the new filter and place the new cartridge into the tank with the double O-ring facing down.

11.  Position the cartridge so that it is aligned with the bottom center opening. 

12.  Press down on the cartridge so that the double O-ring seal moves into place within the bottom center opening.

13.  Reposition the top cap into its original location.

14.  Reattach the top tank snap ring, then pull up on the top cap to seat O-rings.

15.  (If Step 2 was completed, do this step; if not, skip to 16.)

 Close the fitting and shut-off.

16.  Turn the water supply on and open the inlet and outlet valves on the bypass.

17.  Relieve the system of air in the tank as the system fills with water by pushing down on the red depressurization button on 

the top cap of the system. Keep the button pushed down until all the air pressure is completely released, and water comes  
out of the red depressurization button.

18.  Release the red depressurization button.

19.  Return the umbrella cap to the top of the system.

20.  Check for leaks.

21.  Flush the new cartridge per its installation instructions.

22.  During flush, confirm green LED lights are flashing with flowing water. If lights are not flashing green, go back to step 3.

REPLACING THE CARTRIDGE

Summary of Contents for 7-CTFS-NSF

Page 1: ...SOLUTIONS This manual should be kept for future reference If you have any questions regarding your water filter contact your local dealer OEM or the manufacturer at the following Lancaster Water Group 1340 Manheim Pike Lancaster PA 17601 lancasterwatergroup com 1 800 442 0786 ...

Page 2: ...of your home to relieve water pressure by draining it from lines Installing Ground To maintain an electrical ground in metal plumbing of a home s cold water piping such as a copper plumbing system install a ground clamp or jumper wiring The system and installation must comply with state and local laws and regulations NOTES Plumbing the filtration system assembly the inlet and outlet of the filtrat...

Page 3: ... METERASSY 5 Meter Spacer Assembly CT METERSPACER 6 Bypass Manifold CT IOHMBK BYPASSMANIFOLD GR 7 1 MNPT Straight Connector CT 1MNPTSTRAIGHT 8 1 MNPT 90 Degree Elbow Connector CT 1MNPTELBOW 9 3 8 PEX Drain Valve Kit Assembly With Shut off CT 38DRAINVALVEKIT P 10 PCB Umbrella With Electronics Non WIFI Version 1 CT PCBUMBRELLA NONWIFI V1 NOT SHOWN IN DIAGRAM PART IDENTIFICATION PART NUMBER Head and ...

Page 4: ...f Teflon tape Install thread 9 Drain Valve Assembly into 3 HAND TIGHTEN ONLY STEP 1C Connect 4 to 3 Flow Meter Assembly should be placed on the Outlet Side left side at the bottom of the tank Connect 5 Bypass to 3 HAND TIGHTEN ONLY STEP 1D Connect 6 to 4 and 5 HAND TIGHTEN ONLY STEP 1E Use either part 7 or 8 for connecting your plumbing to the system HAND TIGHTEN ONLY STEP 1G Install 3 AAA batteri...

Page 5: ...o pull the cap out of the top of the tank STEP 4A Place the top cap back into its original location STEP 4B Reattach the snap ring then pull up on the cap to lock in the O rings STEP 4 REATTACH THE TOP CAP STEP 5B Slowly turn the water back on Press down on the red button located in the middle of the cap This depressurizes the system and relieves it of air Keep the button pressed down as the water...

Page 6: ...d should be reinstalled into the bottom connection for proper installation of filter 8 Open the fitting and shut off and then flush out the bottom of the system 9 Look down into the tank assembly and locate the small opening centered in the bottom of the tank 10 Remove packaging from the new filter and place the new cartridge into the tank with the double O ring facing down 11 Position the cartrid...

Page 7: ...place the filter in their E3 M system by following a few simple steps LED REPLACEMENT NOTIFICATIONS EASY TO UNDERSTAND LED REPLACEMENT NOTIFICATIONS EASY FILTER REPLACEMENTS WITH NO TOOLS REQUIRED 1 PRESS THE RED PRESSURE RELIEF VALVE TO UNSEAT THE RING 2 REMOVE SNAP RING 3 LIFT TOP CAP GREEN FILTER GOOD Meter preset at 100 000 gallons see page 6 for adjusting presets Three AAA batteries not inclu...

Page 8: ...ou have questions or concerns please contact Lancaster Water Group at 1 800 442 0786 90 Degree Elbow Connectors 2 Umbrella Cap Filter Cap Filter Housing Bypass Manifold In Out Head w Filter Adapter 2 5 Inlet Cap Vertical Elbows 2 Straight Connector Drain Valve Assembly Flow Meter Assembly ...

Page 9: ...filter are not necessarily in all users water WARNINGS Claims are not performance tested by IAPMO or NSF Performance claims are based on independent laboratory and manufacturer s internal test data Actual performance is dependent on influent water quality flow rates system design and application Results may vary This system conforms to NSF ANSI 53 for the specific performance claims verified and s...

Page 10: ...e wait 2 seconds and repeat Refer to the figures below for an example FIGURE 1 To change the maximum gallons setting press and hold the button for 1 second LED 1 should turn solid green LED 2 should turn off and LED 3 should flash green the number of times that corresponds to the current setting Pressing the button for less than 1 second would increment the value rolling over from 9 to 0 Figure 2 ...

Page 11: ...11 ...

Page 12: ...d or translated into another language without the prior written consent of LANCASTER WATER TREATMENT Copyright 2022 LANCASTER WATER TREATMENT All rights reserved POWERED BY Where Innovation Flows This form must be signed and dated by the buyer and seller prior to the consummation of this sale This form should be retained on file by the seller for a minimum of two years Buyer s Name printed Buyer s...

Reviews: