Your purchase and use of SR-1005 carbon monoxide detector is greatly appreciated. Please read the operation instructions BEFORE using the device, 
and make sure to keep this manual after carefully reading it, for the future reference.

• This carbon monoxide detector has been approved for use in homes. It is NOT designed for maritime use or to be used inside caravans.
• If your carbon monoxide detector emits an alarm, never ignore it. Always proceed with appropriate precautions. 
• This carbon monoxide alarm is not a substitute for a gas alarm.  This detector will NOT sense smoke, fire or any other poisonous gas other than carbon 
monoxide. For this very reason you must install smoke alarms to provide early warning of fire  and to protect yourself and your family from fire and 
hazards related to it. 
• This product is intended for use in ordinary indoor residential areas. It is NOT designed to measure compliance with commercial and industrial 
standards. This alarm is NOT suitable for installation in hazardous locations. Individuals with medical problems history may consider using warning 
devices which provide audible and visual signals for carbon monoxide concentrations under 30PPM.  

IMPORTANT: This carbon monoxide alarm is designed to detect carbon monoxide from any source of combustion including improper or malfunctioning 
appliances. The installation of this device should not be used as a substitute for proper installation, use and maintenance of fuel burning appliances 
including appropriate ventilation and exhaust systems.

IMPORTANT: If any fault signals occur, promptly contact the manufacturer or supplier and do not continue using the alarm.

1. CO ALARM, 2. POWER, 3. FAULT, 4. ALARM, 5. DISPLAY, 6. TEST / MENU BUTTON , 7. SPEAKER, 8. ALARM BRACKETS, 9. BATTERY 
COMPARTMENT, 10. BASE PLATE,  11. CLIP 12. CLIP, 13. DRILL HOLES.

2. Technical parameters

• Detection Method: Electronic & Chemical Sensor
• Dimensions: 90 x 120 x 40 mm
• Weight: 201 g
• Power supply: 3 x 1.5V “AA” alkaline batteries
• Operating Temperature: -10

~ +40

• Temperature display: -15

~50

, ±1 

• Environmental Humidity: ≤95% RH
• Static operating current: 80±10 uA
• Alarm current: 45-75 mA
• Alarm loudness: ≥ 85 dB @ 3 m
• Gas intensity scope of LED display: 25-550 PPM (±10%)

3. Operation

• This carbon monoxide detector REQUIRES BATTERIES to work. It will not provide protection if the batteries are removed or not replaced in time.
• High or low temperatures, high levels of humidity, heavy jolts or falls may negatively affect the digital display.
• The carbon monoxide detector measures the level of carbon monoxide in the air. The warning signal will sound when the level of CO rises (e.g. if the 
heat exchanger in your central heating system is broken) or if CO is constantly present (for instance if CO is slowly leaking from an appliance that burns 
fuel). This carbon monoxide detector has a sensor, indicator light and display, an 85-dB warning alarm and a test button. It also has an alarm pause 
button to temporarily mute the alarm. 

IMPORTANT

: Check your carbon monoxide detector each week. Replace the detector immediately if you find it is not working properly.

4. Inserting and replacing the battery

1. Remove the base plate by pulling down clips from alarm brackets.
2. Insert the supplied batteries into the battery compartment.
3. Ensure that the batteries are inserted correctly, you will hear a beep, if that is the case.
4. Replace the base plate.

When  in  standby  mode,  the  digital  screen  alternates  every  40  seconds  between  displaying  the  room  temperature  and  the  CO 
concentration.

The battery is checked every 45 seconds in standby mode. The green POWER lamp flashes every 45seconds. When the battery voltage drops below 
3.5V, the detector will emit a short beep sound. In the event of low voltages, the detector will continue to function further for 7 days.

IMPORTANT: Immediately replace the batteries when the indicator shows that the batteries are flat. Use appropriate batteries and ensure that they 
are inserted properly.

5. Function test and maintenance

1. Press the TEST/MENU button.
2. The POWER/FAULT/ALARM light will flash and then the red ALARM light will flash 4 times.
Meanwhile, the LCD will turn blue and display “

__

”.

To keep your alarm in good working order:
• Test it every week.
• Vacuum regularly to remove dust.
• Keep the detector away from solvents or detergents.
• Avoid spraying air freshener, hair spray near the alarm.
• Do not paint the alarm. If decorating or using adhesives close to the alarm, remove it temporarily.
• Keep away from containers with napkins.

The following substances may affect the sensor and cause false alarms:

Methane, Propane, Iso-butane, Iso-propanol, Ethylene, Benzine, Ethyl acetate, Hydrogen Sulphide, Dioxide, alcohol-based products, paints, thinners, 
solvents, adhesives, hair sprays, aftershaves or perfumes and some cleaning agents.

Failure to carry these steps could result in the premature failure of your device or could pose a threat to your life and anyone inside.

6. Pause function

1. When the CO concentration is less than 150 ppm, the detector will automatically reset itself and return to checking for CO.
2. When the CO concentration is over 150 ppm, the detector will emit an alarm for 5 minutes. The red ALARM light will stay lit. If the CO concentration 
remains over 150 ppm after 5 minutes, the detector will emit an alarm yet again.
Key point: You can press the TEST/MENU button to mute the alarm, but only when you are sure the condition will not harm your health and safety.

WARNING! The pause function is just for your convenience and does not solve carbon monoxide problems. Every time the alarm sounds you should 
have your house inspected for any potential carbon monoxide problems. Never remove the batteries from the detector to stop the alarm. Use the pause 
button to stop / mute the alarm. If you fail to do this, this can lead to serious injuries or even death.

7. History function

Press and hold the TEST/MENU function for 10 seconds. This allows you to read the following:

Indication of the maximum carbon monoxide level measured. The value is shown on the following screen.

7. Sensor fault

The detector will automatically check the sensor every 2 minutes. If the detector is not working properly, the yellow FAULT light will illuminate and the 
display will show “Err”. The sensor check will be carried out every 10 seconds and an alarm will sound.
If the sensor is working correctly, the detector will return to standby mode.

IMPORTANT: The detector may give a FAULT signal for certain gases which are not harmful to humans (e.g. alcohol). Remove the batteries and place 
the detector in the open air for 24 hours. If the detector shows the FAULT indicator again, replace it immediately.

INSTALLATION
• You should fit at least one CO detector near to or inside every bedroom or living room.
• You should fit at least one CO detector on every floor.
• For better protection, fit a CO detector 1-3 meters from heat sources that use fuel.

IMPORTANT: Carbon monoxide is almost as light as air and spreads easily through rooms and houses.
Position the CO detector at least 1.5 meter above the ground, no lower.
NEVER install a carbon monoxide detector:
• In extremely dusty or greasy environments.
• In extremely humid areas. This detector should be fitted at least 3 meters from a bath, shower or washing machine. In spaces with high levels of 
moisture.
• In areas where the temperature can fall below 0 or rise above 45 .
• In places with moving air, such as near to ceiling fans, heating pipes, air conditioning, open windows. Air streams will mean that carbon monoxide only 
reaches the sensor for a short time.
• Outdoors or in direct sunlight.

IMPORTANT: This detector has been designed for use in a small family home. It has not been designed for use in shared accommodation areas. In these 
cases, a detector should be fitted in each housing unit.
The alarm on your CO detector indicates that carbon monoxide is present, which can cause death. You should never ignore the alarm on your detector!

When the detector emits a sound alarm:
1. Press the TEST/MENU button.
2. Call the emergency services or fire brigade immediately.
3. Promptly leave through a door or window to the open air. Count everyone present and check that nobody is missing. Do not return to the property and 
stay away from windows and doors until the emergency services have arrived, your property has been ventilated and your detector is functioning normally.

Carbon monoxide is an invisible, odorless and tasteless gas that is produced by the incomplete combustion of fossil fuels or when fossil 
fuels are exposed to heat. Household heating appliances are often sources of carbon monoxide.

9. Symptoms of Carbon Monoxide poisoning

10. Important safety information

Note: If you recognize any of the above symptoms contact your doctor immediately.
Note: Young children, elderly and pets are more susceptible to the dangers of CO.

ATTENTION!!! The returns will be impossible if products were used or damaged because of incorrect use.

Disposal

The packaging material is reusable. Dispose of the packaging in an environmentally friendly way by putting it in the appropriate recyclable waste 
collection containers. 
Dispose of the product and the batteries in view of the environment if you want to separate. The device and the batteries must not be thrown in with 
domestic waste. Take them to a recycling center for used electrical and electronic devices. For more information you can consult your local government. 
Remove batteries first. 

Warranty

This product is covered by 24-month warranty.

Part Per Million (PPM) 

Effects on Adults

The maximum concentration that the healthy adults can endure 

within 8 hours.

50 PPM

200 PPM

400 PPM

Dizziness and headache within 2-3 hours.

Nausea, frontal headache, drowsiness, confusion and rapid heart rate. Risk to 

life after over 3 hours of exposure.

Severe headaches, convulsions, vital organ failure, death possible within 2-3 

hours.

800 PPM

EN

PL

Summary of Contents for SR-1005

Page 1: ...USER MANUAL INSTRUKCJA OBSŁUGI SR 1005 CARBON MONOXIDE ALARM CZUJNIK TLENKU WĘGLA ...

Page 2: ...is product is intended for use in ordinary indoor residential areas It is NOT designed to measure compliance with commercial and industrial standards This alarm is NOT suitable for installation in hazardous locations Individuals with medical problems history may consider using warning devices which provide audible and visual signals for carbon monoxide concentrations under 30PPM IMPORTANT This car...

Page 3: ...exchanger in your central heating system is broken or if CO is constantly present for instance if CO is slowly leaking from an appliance that burns fuel This carbon monoxide detector has a sensor indicator light and display an 85 dB warning alarm and a test button It also has an alarm pause button to temporarily mute the alarm IMPORTANT Check your carbon monoxide detector each week Replace the det...

Page 4: ...will flash and then the red ALARM light will flash 4 times Meanwhile the LCD will turn blue and display To keep your alarm in good working order Test it every week Vacuum regularly to remove dust Keep the detector away from solvents or detergents Avoid spraying air freshener hair spray near the alarm Do not paint the alarm If decorating or using adhesives close to the alarm remove it temporarily Kee...

Page 5: ...ouse inspected for any potential carbon monoxide problems Never remove the batteries from the detector to stop the alarm Use the pause button to stop mute the alarm If you fail to do this this can lead to serious injuries or even death 7 History function Press and hold the TEST MENU function for 10 seconds This allows you to read the following Indication of the maximum carbon monoxide level measur...

Page 6: ... extremely dusty or greasy environments In extremely humid areas This detector should be fitted at least 3 meters from a bath shower or washing machine In spaces with high levels of moisture In areas where the temperature can fall below 0 or rise above 45 In places with moving air such as near to ceiling fans heating pipes air conditioning open windows Air streams will mean that carbon monoxide onl...

Page 7: ...tally friendly way by putting it in the appropriate recyclable waste collection containers Dispose of the product and the batteries in view of the environment if you want to separate The device and the batteries must not be thrown in with domestic waste Take them to a recycling center for used electrical and electronic devices For more information you can consult your local government Remove batte...

Page 8: ...rodukt jest przeznaczony wyłącznie do użytku w pomieszczeniach mieszkalnych Nie nadaje się do wykorzystania wewnątrz wymagających obiektów przemysłowych lub miejscach wysoce niebezpiecznych Osoby z przewlekłymi problemami zdrowotnymi powinny rozważyć wdrożenie dodatkowych urządzeń ostrzegających które dostarczają sygnały dźwiękowe i wizualne przy wykryciu stężenia tlenku węgla wynoszącego poniżej ...

Page 9: ... 10 3 Działanie urządzenia Ten czujnik tlenku węgla WYMAGA BATERII do prawidłowego działania Urządzenie nie będzie w stanie zapewnić użytkownikom ochrony jeśli baterie zostaną wyjęte z komory lub jeżeli zużyte baterie nie zostaną wymienione na czas Ponadto bardzo wysokie niskie temperatury wysoka wilgotność silne wstrząsy lub upadki mogą uszkodzić prawidłowe funkcjonowanie cyfrowego Poziomy alarmu...

Page 10: ...rawidłowo usłyszysz sygnał dźwiękowy D Załóż z powrotem podstawkę urządzenia W trybie gotowości wyświetlacz cyfrowy urządzenia pokazuje naprzemiennie co 40 sekund temperaturę w pomieszczeniu oraz stężenie CO Bateria urządzenia jest automatycznie sprawdzana co 45 sekund w trybie gotowości czujnika czadu o czym informuje migająca dioda POWER Częstotliwość co 45 sekund Kiedy napięcie baterii spadnie ...

Page 11: ...ik czadu automatycznie się zresetuje i powróci do wykrywania CO B Jeżeli stężenie czadu przekroczy 150ppm czujnik uruchomi alarm trwający 5 minut Czerwona dioda ALARM zaświeci się Jeśli stężenie CO nadal utrzyma się powyżej wartości 150ppm po 5 minutach urządzenie ponownie uruchomi alarm UWAGA Możesz nacisnąć przycisk TEST MENU aby włączyć funkcję pauzy tylko I wyłącznie w sytuacji kiedy masz PEWN...

Page 12: ... 2 minuty Jeśli czujka nie działa prawidłowo żółta dioda awarii FAULT zaświeci się a na wyświetlaczu pojawi się napis Err W tym przypadku kontrola sensora będzie przeprowadzana co 10 sekund i emitowany będzie sygnał dźwiękowy Jeśli sensor działa poprawnie wykrywacz tlenku węgla powróci do trybu gotowości UWAGA Czujnik czadu SR 1005 może emitować sygnał awarii FAULT dla pewnych gazów które nie są s...

Page 13: ...sowaniach w domach mieszkaniach Urządzenie nie zostało zaprojektowane do użytku w obiektach infrastruktury turystycznej hotele motele etc Jeżeli chcemy ten produkt wykorzystać dla powyższego zastosowania wówczas w każdym oddzielnym pomieszczeniu pokoju powinien się znaleźć osobny czujnik czadu Sygnał dźwiękowy czujnika CO oznacza iż stężenie czadu jest wysokie co w konsekwencji może spowodować śmi...

Page 14: ...nika czadu wszystkie baterie w efekcie dbając o środowisko Nie wolno wyrzucać tego produktu i jego baterii razem z odpadami komunalnymi Zakupiony produkt najlepiej zabrać do lokalnego centrum recyklingu zużytych urządzeń elektrycznych i elektronicznych Aby uzyskać więcej informacji możesz skonsultować się ze swoim lokalnym punktem informacyjnym dotyczącym środowiska Nie wyrzucaj produktu razem z b...

Page 15: ...nacza że niniejszy produkt nie może być traktowany jako odpad domowy Prawidłowa utylizacja zużytego sprzętu pozwala uniknąć zagrożeń dla zdrowia ludzi i środowiska naturalnego wynikających z możliwej obecności w sprzęcie niebezpiecznych substancji mieszanin oraz części składowych a także niewłaściwego składowania i przetwarzania takiego sprzętu Zbiórka selektywna pozwala także na odzyskiwanie mate...

Reviews: