SafeLog 100

 

Single Gas 
Datalogging Monitor

 

 

Operator's Manual

 

 

Note:

 Due to the new ATEX Directive in Europe, all 

references in this document to "Ex" or "EEx" for intrinsic 
safety approvals should be disregarded effective 7/1/03 
within the member countries of the European Union (EU). At 
this time, this product is not approved in accordance with the 
new ATEX Directive and is not sold for use in hazardous 
atmospheres or explosive zones by customers within the 
EU.  Outside of the EU, all references to intrinsic safety 
continue without change. 

 

Thank you for choosing Quest Technologies to meet your personal gas moni-
toring needs. The SafeLog 100 is an extremely rugged, lightweight single gas 
datalogging personal monitor. It is our goal to make your decision to buy Quest 
products the right one, and to provide support for any questions or concerns that 
might arise.

 

 
The purpose of this manual is to provide the user with the necessary information 
to operate the SafeLog 100. The entire manual should be read to fully 
understand the many features this instrument offers.

 

 
This manual is not all inclusive and cannot cover all unique situations. In addi-
tion, no warranties are contained in this manual except as described under the 
warranty policy section.

 

 
Copyright 1997 Revision B

 

P/N 054-479

 

 
 
 
 
 
 
 
 
 
 
 
 

 

 

1060 Corporate Center Drive • Oconomowoc, WI 53066 USA • 800-245-0779 • Fax:262-567-4047

 

http://quest-technologies.com 

Printed in U.S.A.

 

Содержание SafeLog 100

Страница 1: ...oni toring needs The SafeLog 100 is an extremely rugged lightweight single gas datalogging personal monitor It is our goal to make your decision to buy Quest products the right one and to provide supp...

Страница 2: ...Date 12 3 3 8 Temperature 12 3 3 9 Password 12 3 4 Zero Mode 12 3 5 Print Mode Reset 13 3 5 1 Print 13 3 5 2 Reset 13 3 6 Run Mode 13 3 7 Zeroing 13 3 8 Calibration 14 3 8 1 Minimum Flow Rate Table 16...

Страница 3: ...All recorded data can be sent to a printer or computer for record keeping or further data analysis Like many of Quest s data logging instruments the SafeLog 100 works with the QuestSuite software pac...

Страница 4: ...s level is exceeded the alarm activates and the alarm value is shown on the display 2 3 4 STEL This annunciator which stands for Short Term Exposure Limit is present only when using a toxic gas sensor...

Страница 5: ...t is also on during all alarming conditions 3 UNIT OPERATION 3 1 Turning the Unit ON Press ON OFF The following startup sequence will occur 1 All of the display segments appear simultaneously on the s...

Страница 6: ...he display For the TWA alarm toxics only HI and TWA will be on the dis play Pressing the enter key causes the first digit to flash Use the arrow and enter keys to adjust the level 3 3 5 Confidence Chi...

Страница 7: ...r adjusts for small baseline drifts which occur over time in electrochemical sensors Zero the unit by pressing the zero key from the display with four dashes or as one of the options available through...

Страница 8: ...and TWA alarm conditions are checked every minute If any alarm setting is exceeded the buzzer and LED turn on the value causing the alarm is displayed and the alarm condition and time of occurrence a...

Страница 9: ...o a computer or in parallel to a printer Serial data transmission requires the Quest cable 54 715 and par allel data transmission requires the Quest cable 56 875 With the cable plugged into the unit p...

Страница 10: ...4 3 Sample Printout...

Страница 11: ...ery voltage drops below the usable range dEAd appears in the display the buzzer activates for approximately 25 seconds then the unit turns itself off The 9 volt alkaline battery must be replaced prior...

Страница 12: ...e new one A circular hydrophobic filter sits in the opening on top of the sensor module make sure the new sensor has a filter in place prior to reinstalling the top cap Set the top cap back on the uni...

Страница 13: ...GAS SPECIFIC DATA Gas Range Reso lution Accur acy Drift Alarm High Alarm LOW Oxygen O2 0 30 0 1 5 1 23 5 19 5 Sensor accuracy listed by City Technology as a percentage of the reading Long term output...

Страница 14: ...o 140 F storage Humidity 0 to 95 R H non continuous non condensing Range 15 to 90 R H continuous non condensing Warranty Sensors 1 year electronics 1 year Cell Life Ammonia sensor 1 year in air or 2pp...

Страница 15: ...tion Kit 54 974 Two Cylinder Calibration Kit Includes two cylinder calibration case regulator specify which regulator and tubing 12 4 Regulators 54 971 0 5 1pm Regulator with 2 050 I D tubing 54 972 1...

Страница 16: ...ipping damage please direct your calls or letters to the attention of the Service Manager Quest Technologies 262 567 9157 or 800 245 0779 Office hours are from 7 AM to 6 PM Central Standard Time Monda...

Страница 17: ...1060 Corporate Center Drive Oconomowoc WI 53066 USA 800 245 0779 Fax 262 567 4047 http quest technologies com Printed in U S A 054 479 Rev B...

Отзывы: