42
Call 1-888-370-6531 for Technical Support
8.4 Heater Specifications
Multi-Fuel Burning Appliance
Model Number
75H
Bonnet Capacity
Output
58,922 BTU/Hour
Fuel Input
0.54 GPH
Nozzle Only
30609-11
Approved Fuels
ASTM D396 No. 2 Fuel Oil, Used Crankcase Oil, and Used
Automatic Transmission Fluid
Designed Outlet Air
Temperature
250°F Maximum
Tank Capacity
10 Gallons (Approx. 7 Usable)
Flue Draft
-0.04" WC (Minimum 10’ Stack)
Atomizing Air
Pressure
3-4 PSI
Fan Size
13"
Flue Size
6”
Unit Heater
No Ductwork
Fuse Size
8A (15A Max)
Burner Motor
1/7 HP, 115V/60Hz, 3450 RPM, 1.5A
Metering Pump
Motor
15Watt, 115V/60Hz, 0.3A
Ignition Transformer
& Control Circuit
115V/60Hz, 1.0A
Oil Preheaters
115V/60Hz, 3.0A Maximum
Heater Weight (Tank
Empty)
210 lbs
Heater Dimensions
75”H x 21”W x 26”L
Minimum Clearance
to Combustible
Surfaces
Top - 18"
Front - 24"
Sides - 18"
Rear - 6"
Flue Pipe - 18"
For commercial and industrial use only.
The heater should not be used in buildings where explosive vapors may be present.
The heater should be mounted to non-combustible flooring.
Summary of Contents for MX 75
Page 2: ......
Page 41: ...8 Appendices 8 1 Wiring Diagram ...
Page 42: ......
Page 43: ...34 Call 1 888 370 6531 for Technical Support 8 2 Primary Control Instructions ...
Page 44: ...35 Call 1 888 370 6531 for Technical Support Not used with RES 75 kBTU h units ...
Page 45: ...36 Call 1 888 370 6531 for Technical Support No latch up with RES 75 kBTU h units ...
Page 46: ...37 Call 1 888 370 6531 for Technical Support ...
Page 54: ...45 Call 1 888 370 6531 for Technical Support 9 ...