133
10
Appendix
Selective list of Turck NAMUR sensors
10.10 Connection Diagram Relay Modules
Fig. 10-15 Relay module type 660 R 0013 / 660 R 0131
Fig. 10-16 Relay module type 660 R 0019
Type
sn [mm]
sn x 0,8 [mm]
D [mm]
f [Hz]
Installation
Bi1-EG05-Y1
1
0,8
5
5.000
flush
Bi1,5-EG08K-Y1
1,5
1,2
8
5.000
flush
Ni3-EG08K-Y1
3
2,4
8
5.000
non-flush
Bi2-G12-Y1
2
1,6
12
5.000
flush
Ni5-G12-Y1
5
4
12
2.000
non-flush
Bi5-G18-Y1
5
4
18
1.000
flush
Ni10-G18-Y1
10
8
18
500
non-flush
Bi10-G30-Y1
10
8
30
500
flush
Ni15-G30-Y11
15
12
30
200
non-flush