SAFETY NOTICES AND TERMINOLOGY USED 

 

Warning! 

 
 

 

Warning

!”  Denotes a potentially dangerous situation. Failure to comply with these 

notices can result in serious injury or even death. 

 

Caution! 

 
 

 

Caution

!”  These notices show a situation that can result in minor injury or damage to 

property if not complied with. 

 

Please note! 

 
 

 

Please note

!”  Points out situations where ignoring the safety notice can negatively 

affect the result of work being carried out and damage the equipment. 

 

Important! 

 

 

 

 

Important

!”  Notices are helpful hints and other particularly useful pieces of information. 

They do not indicate a potentially dangerous or harmful situation. 

 

 

 

 

 

 

DESIGNATED USE 

 

  

The application of welds to metals and alloys that, because of their physical properties, 
can be considered as weldable. 
It is prohibited to use this apparatus to carry out welds in, or on, the body. 

 

 

  

Any other application of the appliance other than the above stated, is prohibited. 

 

  

It is prohibited to use this apparatus out of doors. Use only in dry surroundings! 

 

  

No liability of any kind will be assumed for the durability of welds. We recommend 
that welds are always inspected. 

 

 

 

 

 

 

INTRODUCTION 

 

  

The PUK U3 is a TIG-impulse-precision welding device, which allows the placing of 
precise and very fine welds. Its small size, low weight and minimum energy consumption 
are not just important facts of the PUK U3, but also very beneficial attributes. Its excellent 
ignition and welding characteristics permit a broad spectrum of applications and a wide 
range of uses. By bringing new possibilities to the world of welding engineering, an 
entirely new “welding” dimension is available to the fields of production and repairs. 

 

 

 

 

 

Summary of Contents for PUK U3

Page 1: ...fore first using your PUK U3 please be sure to carefully read the manual sections General Safety Requirements and Personal safety and the separately attached Safety Precautions Please retain these ins...

Page 2: ...unctions and features back 7 4 4 Starting up 7 9 4 5 Changing language displayed 9 5 OPERATING PRINCIPLES AND SETTING THE PARAMETERS 10 5 1 Adjusting the welding parameters 10 5 2 Using the programmab...

Page 3: ...properties can be considered as weldable It is prohibited to use this apparatus to carry out welds in or on the body Any other application of the appliance other than the above stated is prohibited It...

Page 4: ...fers depending on the type of welding current the type of power source and the potential for electrical hazard of the workplace If it can be assumed that a safe operation of the device is no longer po...

Page 5: ...e Those lingering or working in close proximity to the electric arc must be made aware of the risks and supplied with the appropriate protective equipment Wherever necessary a protective screen should...

Page 6: ...ds ms 9 Current mode setting Standard mode Gap mode HF Pulse mode Resistance welding Micro mode 10 Program indicator P1 P10 The foot switch function can be recognised by this symbol Please note In the...

Page 7: ...ease note The connection socket for the foot switch the glare protection system and the LED microscope lighting are identical 16 CONNECTOR FOR INERT GAS HOOKUP ARGON GAS For pressure hose 6 mm 17 IDEN...

Page 8: ...otection system welding microscope USM may be connected to the PUK U3 Other glare protection systems are not permitted and can result in permanent health damage or lead to the damaging of the machine...

Page 9: ...will run a self test Please note Please also follow the guidelines given in the operating instructions of the attached welding microscope USM Caution As soon as the mains power switch of your PUK U3...

Page 10: ...accidentally changing the parameters the settings that were last used are there to be recalled again Please note Please remember that only when the gas flow rate has been correctly set up and adjuste...

Page 11: ...have lower output levels that can be set in finer increments making it ideal for use with very small cross sections of material Especially important to note always use a sharp electrode 5 2 USING THE...

Page 12: ...ings not stored This is to avoid the blocking of a memory slot with a duplication of already stored information In this case the memory slot where the original setting is stored will blink The process...

Page 13: ...By again holding the foot switch pressed for ca 1 second without contacting the work piece the footswitch function can be deactivated The symbol will disappear from the display WELDING INSTRUCTIONS R...

Page 14: ...When choosing the output levels of parameters make allowances for the thickness of the material which is to be welded and adjust settings accordingly Work with as much precision as possible contact t...

Page 15: ...arning IF FUSES NEED TO BE EXCHANGED THESE ARE ONLY TO BE REPLACED WITH FUSES OF THE SAME SPECIFICATION USING FUSES OF A HIGHER VALUE WILL INVALIDATE ANY WARRNTY CLAIMS The PUK U3 may only be opened b...

Page 16: ...AC Tungsten inert gas welding Direct current 1 50 60Hz Power plug single phase Alternating current 50 60Hz Read the manual Rated no load voltage Rated supply voltage Protective earth Conventional loa...

Page 17: ...servicing please contact your dealer Use Argon inert gas Wherever possible use Argon with a purity of 99 996 i e Argon 4 6 6 Oxidation and the forming of soot 7 Welding spots are heavily oxidised The...