Using the PUK 6 7
Issue EN 2022/05 PUK 6 Operating manual
45/56
DANGER!
Hazard due to electromagnetic radiation
Pacemakers and other medical implants can be damaged due
to electromagnetic radiation. Cables carrying welding current
must also not be wrapped around the body. Both can lead to
the complete failure of medical implants.
The device generates a strong electromagnetic field during
operation. If you are a medical implant user, check with
the implant manufacturer or an authorised medical profes-
sional before using the device. If use is possible, clarify
the required minimum distance in advance and do infringe
upon this distance at any time when working with the de-
vice.
Proceed as follows:
1)
Make sure that the mains cable is connected to the device and the
socket.
2)
Check the gas connection and carefully open the gas cylinder valve.
3)
Set the power switch to "I".
4)
Read the safety instruction on the display and confirm it by pressing the
rotary-push control.
The device is now ready for operation
7.3
Welding with the PUK 6
CAUTION
Hot surfaces
Danger of burns to the skin
It is absolutely essential to wear gloves when welding
WARNING
Optical radiation
Danger of eye damage
Suitable eye protection must always be worn during weld-
ing.