TRACER

EC/TDS/SAL POCKETESTER

TM

• CODE 1749

TABLE OF CONTENTS

Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Contents. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

5

Parts & Accessories . . . . . . . . . . . . . . . . . . . . . . . . . .

5

Meter Description

Front Panel Description . . . . . . . . . . . . . . . . . . . . .

6

TRACER Display . . . . . . . . . . . . . . . . . . . . . . . .

6

Basic Operation

Powering the TRACER . . . . . . . . . . . . . . . . . . . . .

7

Electrode Recognition . . . . . . . . . . . . . . . . . . . . . .

7

Automatic Calibration . . . . . . . . . . . . . . . . . . . . . .

7

TDS Conversion Ratio . . . . . . . . . . . . . . . . . . . . . . 7
To Change the TDS Conversion Ration . . . . . . . . . . . . . 7
Changing the Displayed Tempreature Units . . . . . . . . . . . 8
Data Hold . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Testing

Getting Started . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Changing the Measurement Function. . . . . . . . . . . . . . . 9
Measurement . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Measuring the TDS of Soil . . . . . . . . . . . . . . . . . . 10-11
Storing Readings . . . . . . . . . . . . . . . . . . . . . . . . . 11
Recalling Stored Readings . . . . . . . . . . . . . . . . . . . . 11

Calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Maintenance

Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

13

Battery Replacement . . . . . . . . . . . . . . . . . . . . . .

13

Electrode Care . . . . . . . . . . . . . . . . . . . . . . . . .

13

Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . .

14

Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

3

Summary of Contents for POCKETESTER EC/TDS/SAL TRACER

Page 1: ...TRACER Waterproof Series EC TDS SAL CODE 1749 POCKETESTER...

Page 2: ......

Page 3: ...ode Recognition 7 Automatic Calibration 7 TDS Conversion Ratio 7 To Change the TDS Conversion Ration 7 Changing the Displayed Tempreature Units 8 Data Hold 8 Testing Getting Started 9 Changing the Mea...

Page 4: ...19 99 mS TDS Range 0 to 99 9 ppm and mg L 100 to 999 ppm and mg L 1 00 to 9 99 ppt and g L Salinity Range 0 to 99 9 ppm S 100 to 999 ppm S 1 00 to 9 99 ppt S TDS Ratio 0 4 to 1 0 adjustable Salinity R...

Page 5: ...individually See below Parts Accessories EC TDS SAL Replacement Electrode Code 1765 Weighted Stand w Sample Cups 5 Code 1746 Sample Cups w caps 24 Code 1745 24 Conductivity Standard 84 mS Code 6312 G...

Page 6: ...perature units recall data 5 ON OFF button 6 Electrode Collar 7 Electrode Note The Electrode cap is not shown TRACER Display 1 Bar graph reading 2 Measurement reading 3 BAT low battery indicator 4 Tem...

Page 7: ...alibration is completed the SELF and CAL display icons will extinguish TDS Conversion Ratio The TDS value is determined by multiplying the conductivity measurement by a known conversion ratio factor T...

Page 8: ...or F 1 With the TRACER off press and hold the CAL button 2 Press the ON OFF button When SELF CAL appears in the display release the CAL button Data Hold Press the MODE HOLD button to freeze the curre...

Page 9: ...eter can be set to measure Conductivity TDS ppm TDS mg L or Salinity To change the mode 1 Turn the TRACER on 2 Press and hold the MODE HOLD button for 3 seconds The display will begin to scroll throug...

Page 10: ...rode in distilled water Replace the cap Measuring the TDS of Soil 1 Fill a 50 mL beaker with the soil sample Tap the beaker lightly on a hard surface to remove trapped air Remove excess soil from the...

Page 11: ...n 15 readings the stored readings will be overwritten starting with the first reading Recalling Stored Readings NOTE First ensure that the HOLD symbol is not displayed If it is exit the HOLD function...

Page 12: ...be done first to obtain the best accuracy 2 Insert the electrode into the standard 3 Press and hold the CAL button for approximately 5 seconds until the display begins to flash 4 The meter will autom...

Page 13: ...SR 44 button batteries Observe polarity 3 Replace battery compartment cap NOTE If the batteries are removed stored readings will be lost Calibration data will be retained Electrode Care 1 Always rins...

Page 14: ...ay frozen HOLD function Press MODE HOLD button or turn meter off Button response Remove then reinsert batteries stored data will be lost Replacing the Electrode 1 Unscrew and remove the electrode coll...

Page 15: ...s freight insurance and proper packaging to prevent damage in transit This warranty does not apply to defects resulting from action of the user such as misuse improper wiring operation outside of spec...

Page 16: ...TE COMPANY Helping People Solve Analytical Challenges PO Box 329 Chestertown Maryland 21620 USA 800 344 3100 410 778 3100 Outside U S A Fax 410 778 6394 Visit us on the web at www lamotte com 1749 MN...