8.8 Extraction air system assembly
The hob and the fan can be connected with a flexible
hose or with the addition of flat ducting for island
configurations. Flexi duct can be cut with a knife.
Shorten the flat duct with a fine saw if necessary,
smooth ends and ensure no bumps.
Option 1
flexible hose
Option 2
flat duct
On point c
The flexible connection piece. Please make sure that the
hose is as taut and crease-free as possible by trimming
excess material.
On point f
Apply sealing tape to the plinth fan connecting pieces (f)
before attaching the adapter piece (d) to the plinth fan
(e).
Important:
The components must all be firmly fastened as shown
with the adhesive tape enclosed after they have been
attached.
Fan
Sealing tape
Exhaust air duct components (inclusive):
Carbon filter:
Carbon filter unit
Spares
LAM2007 replacement carbon filter (Replace every 5-24
months depending on use).
*
*