CAUTION, READ CAREFULLY
The TERMOBOILER models are a series of high-performance water
boilers (over 92%), which exploits the combustion heat. The consequence
of these performances is a low temperature of fumes exiting the boiler,
around
60- 110°C
. For this reason you must absolutely follow the
requirements listed below :
A. Build a fume-exhaust duct suitable for solid fuel
condensation and resistant against condensation
–
vacuum pressure operation (N1) but airtight at a pressure up
to 0.2 mbar. Refer to standard UNI 10683 :2012
B. Install a 1” anti-condensation valve with 55°C opening.
C. Connect the room programmable thermostat to the
external terminal board using a "NO" potential free
contact.
D. Setting the boiler water temperature at 70°C.
E. We recommend not using the "chrono" mode on the
boiler to prevent storage temperature from lowering and
lack of domestic hot water when requested.
IMPORTANT!
If incorrect combustion occurs (check if white
fume exits the chimney flue), switch the boiler off and
immediately contact the T.A.S. to prevent condensate from
propagating in the boiler.