25
ELECTRICAL CONNECTIONS
The connections to be made by the installer are as follows:
●
Electrical supply line
●
Thermostat line
●
Warning light (optional)
●
Timer (optional)
●
Flame control thermostat (optional)
(Eliminate any cable bridges)
N.B.: It is necessary to observe scrupulously normal working practices that indicate attachment of no more
than two cables per terminal.
Warning:
●
Do not exchange the neutral with the phase
●
Be sure to make a good connection for the ground wire
●
Respect normal working practices and observe scrupulously local regulations in force
ECO 30
MPE
LOA 24.../LMO14...
LEGEND
F
Fuse
MB
Burner Motor
FA
Matched Filter
MPE
Landis Device Clamp
FCA
Auxiliary Circuit Fuse
TC
Furnace Thermostat
FR
Photo resistance
TS
Back-up Thermostat
IG
Main Switch
TR
Ignition Transformer
Ima
On/Off Switch
VE1
1° Flame Electromagnetic Valve