Flame signal
The flame signal value is displayed in uA.
Cl
one
I LI II IL
Flam e
signal
------
in m icro A
О О О
LILI.LI
uA
If the flame signal read should exceed the flame signal detection threshold value by 10 times, the display is:
Cl one
I L I II IL
Flam e
signal
—
in m icro A
О
О
О
ULI.Ll
uA
Air damper servo-motor
The current position of the air damper servo-motor is displayed (closure total, first stage, total opening or second
stage).
TWO-STAGE BURNER
ОГ L О
I I
U С I
ooooo
о о о о о
г
и
I
и
С
-
с г
пс с
и ОС
-
п
_
IUI
I си
пос.
I JL IJI 1_»
I
If servo-motor
anomaly present
MODULATING BURNER
o r и о
I I L L
I
OOOOO
UUUUU
Г
I
ncc
U —
IL
- n
_
I
и I
m _
п о и
I
II П I
1ПП
If servo-motor
anomaly present
If modulating burner is selected, the percentage opening of the damper with respect to the minimum position is
also indicated.