background image

ENGLISH

GENERAL

- 2 

-

 

It is absolutely forbidden the eliminating of this protection since it is directly connected to the fire safety.

 

The contact between the burner and the boiler should be well tight in order to prevent gas leaks in the service room.

 

When installing the system, it should be in optimal horizontal position.

 

The hose should be straight and the connections should be tight.

 

After connecting the burner to the boiler, the technician should connect the burner to the electrical network as shown on 

the enclosed connection scheme.

 

The connection must be done by a qualified electrical technician and there must be paid high attention to the safety 

grounding of the device. 

 

The connecting is shown in the present manual and also with special stickers to the main cable.

 

The auger transporter connects by a special plug and switch and it is controlled by a special algorithm (there are two plugs 

on the burner, 

ATTENTION! THE DOWN PLUG CH IS CONSTANTLY LIVE AND IS DESIGNED FOR INITIAL CHARGING 

OF THE AUGER

, the other one is for normal work. This is shown with stickers on the plug and on the pin-plug).

 

The burner is designed 

ONLY FOR BURNING PELLETS FROM WOODEN FRAGMENTS!

CONSTRUCTIVE SAFETY RULES

 

The process of ignition and burning is being monitored by a microprocessor or logistical module.

 

There is an end exclusion mechanism on the burner’s frame and a special T-figured detail which does not allow starting 

of the burner if it is not attached to the boiler (for example when cleaning up the boiler). If during work there is received 

a signal from the exclusion mechanism for bad mounting of the burner, its work will be automatically stopped and this 

will be shown with blinking of lamp ALARM. 

  After fixing the disturbance in the normal work, the burner starts with its switching off and on. 

  This can be done by the POWER switch placed on the burner’s cover (it stoppes the feeding of the logistical module in 

the burner and clears the alarm), or by stopping the common feeding of the boiler through its main switch.

 

The process of ignition and burning is being monitored by a photo sensor and if does not ignite after few attempts (adju-

stable function), the burner goes into stop-mode with activated alarm.

 

If during work the pellets bring to end into the feeding bunker, the burner goes into stop-mode with activated alarm.

 

The flexible tube for transporting the pellets is transparent and made of a special heat-resistant material.

 

The customer’s access to the microprocessor logistical module’s program is secured by a password. Only few parame-

ters about the normal work of the burner can be accessed by the customer.

 

There have been used stickers, maximum showing the correct usage of the burner. The burner is provided with elemen-

ts, securing the right burning of the fuel:

 

Falling shaft – it stops the flow of pellets from the auger transporter to the burner. This shaft is deep about 250 mm.

  Besides the transporter is connected to the burner by a flexible hose, which is not full of pellets. In the burner there are 

only a dose of pellets which burns out during the pause of the transporter and the safe burning of the fuel is secured.

 

A sensor for temperature higher than 90-95°C – it is placed on the feeding tube of the burner. 

  If during work the temperature sensor detects a temperature higher than 90–95°C, the auger transporter stops and the 

burner turns off. At this time a lamp ALARM starts to blink.

  Even if the temperature falls below 90–95°C, the burner won’t start working again. It is necessary the intervention of the 

operative staff. After fixing the error in the normal work, the burner starts by its turning off and on. 

  This can be done by the POWER switch placed on the burner’s cover (it stoppes the feeding of the logistical module in 

the burner and clears the alarm), or by stopping the common feeding of the boiler through its main switch.

Summary of Contents for GP 20

Page 1: ...BRUCIATORE A PELLET PELLET BURNER BR LEUR PELLETS GP 20 LIBRETTO DI INSTALLAZIONE E MANUTENZIONE INSTALLATION AND MAINTENANCE MANUAL NOTICE D INSTALLATION ET D ENTRETIEN...

Page 2: ...ty installation use and maintenance of the burner Keep the manual in a safe place for future consultation Installation must be carried out by qualified personnel in conformance with technical standard...

Page 3: ...ATION 36 USe and MAIntenance MAINTENANCE Page 38 BURNER MAINTENANCE 40 POSSIBLE TROUBLESHOOTING 41 Complimenti on your excellent choice And thank you for choosing our products LAMBORGHINI CALORECLIMA...

Page 4: ...et Tracking the burning process photo heating and positioning sensors Light signalization for the burner performance Controlling microprocessor Ignition automatic Possibility for adjusting the outgoin...

Page 5: ...R switch placed on the burner s cover it stoppes the feeding of the logistical module in the burner and clears the alarm or by stopping the common feeding of the boiler through its main switch The pro...

Page 6: ...GENERAL 28 DESCRIPTION OF THE CONSTRUCTION 40 2 4 220 165 251 34 178 272 5 1 1 Burner 2 Auger transporter 3 Flexible tube...

Page 7: ...ter Flexible tube Body feeding chute and cover Fan Ignite heater Control block Sensors exclusion mechanism photosensor thermoswitch The burner contains mainly of the following composition parts Body w...

Page 8: ...PTION CODE 1 Auger s engine GP 20 A CODE 001 2 Auger spring GP 20 A CODE 002 3 Auger s tube GP 20 A CODE 005 4 Fan GP 20 CODE 008 5 Logical module GP 20 CODE 009 6 Feeding module GP 20 CODE 009BPS 7 I...

Page 9: ...ENGLISH GENERAL 31 POSITION OF THE ELEMENTS...

Page 10: ...GENERAL 32...

Page 11: ...ENGLISH GENERAL 33...

Page 12: ...scheme ATTENTION The connection must be done by a qualified electrical technician and there must be paid high attention to the safety grounding of the device The connecting is shown in the present man...

Page 13: ...iler ALARM Thermostat Brown Black Power 220 V Neutral conduct Blue Yellow green First feeding of the auger Start burner signal for logic module Photosensor Photocell flame detector Feeding and fitting...

Page 14: ...stat must be set at 80 90 C In this case the burner is fed with pressure the POWER light is on there is a signal from the boiler to the burner to start the RUN light is on and the burner starts for ex...

Page 15: ...nto the burner and clears the alarm or by turning off the common boiler feeding through its main circuitbreaker When the electrical supply stops and then restores the burner starts automatic TURNING T...

Page 16: ...tempts for new ignition end The number of the ignition attempts is n 1 where n is the setting of counter C1 If at n 1 attempts the ignition is not reached at the n attempt in this case the third attem...

Page 17: ...decrease the pellets feeding If the temperature is too low increase the quantity of the air supply if the pellets level in the burner is too low check the flue gases temperature see above and decreas...