USE ANd MAINTENANcE
-
-
MAINTENANCE
ADJUSTING THE CONTROLLING LOGISTICAL MODULE
The logistical module controls the burner. It is secured by a password, so that the currently running program will be safe
from undesirable changes.
The possible settings of the parameters are as they follow (in the brackets are shown the original manufacturer’s settings):
- timer T1 – time for initial pellets feeding (01:30 min.)
- timer T2 – maximum ignition time (07.00 min.)
- timer T3 – filter S (10.00 sec.)
- timer T4 – time for pellets feeding in standing mode (12:00 sec.)
- timer T5 – time for burning after stop-command (10:00 min.)
- timer T6 – time for burning in standing mode (12:00 sec.)
- timer T7 – time for burning of a first dosage (00:30 min.)
- timer T8 – filter (05.00 sec.)
- counter C1 – counter of the ignition attempts (0003)
Remark:
As soon as flame from the photosensor is registered, the attempts for new ignition end.
The number of the ignition attempts is n-1, where n is the setting of counter C1.
If at n-1 attempts the ignition is not reached, at the n attempt (in this case the third attempt) the system gets into emergency
mode (a signal lamp ALARM lights).
An intervention is necessary (check the reason for the unsuccessful attempts).
The alarm clears through the burner turning off by its switch.
The available for settings parameters during work are the following:
- timer T1 – time for initial pellets feeding
- timer T2 – maximum ignition time
- timer T4 – time for pellets feeding in standing mode
- timer T5 – time for burning after stop-command
- timer T6 – time for burning in standing mode
- timer T7 – time for burning of a first dosage
- counter C1 – counter of the ignition attempts
With their help and with adjusting the air valve can be set the burner power (an analyze of the flue gases is necessary to
be made with appropriate gauge instruments, so the burning process will be optimized).
I1