background image

25

UK

WIRING

The wiring scheme to be carried out by technician are:

- Power Supply Line

- Thermostats Line

- Eventual blocking lamp and/or hour-meter

ATTENTION:

- Do not invert neutral with phase.

- Ensure a good earth connection.

VE

FR

LS

N

PB

SC

TC-TA

B4

T2 T1

L1

S3

N

CO

H

Z

N

N

L

IG

F

TS

M

MB

FA

TR

1 2 2 2 3 4 5 6 7 8 9 10 11 12

MA

FOCUS PRO 3 - FOCUS PRO 6

Key

CO

 Hour-meter

F

 

Fuse

FA

 

Anti-interference filter

FR

 

Photoresistance

IG

 

Main switch

LS

 

Safety lamp

MA

 

Control box

MB

 

Burner motor

PB

 

Burner connector

SC

 

Plug

TA-TC

  Boiler environment thermostat

TR

        Ignition transformer

TS

 

Safety thermostat

VE

 

Electromagnetic valve

Summary of Contents for FOCUS PRO 3

Page 1: ...OIL BURNER BRULEURS A FIOUL DOMESTIQUE A UNE ALLURE QUEMADOR DE GAS LEO DE UNA ETAPA MANUALE DI INSTALLAZIONE E MANUTENZIONE INSTALLATION AND MAINTENANCE MANUAL NOTICE D INSTALLATION ET D ENTRETIEN M...

Page 2: ......

Page 3: ...ut by qualified personnel who will be responsible for respecting existing safety regulations FRANCAIS 35 Lire attentivement le mode d emploi et les instructions du pr sent livret car ils fournissent d...

Page 4: ...ori godono di una GARANZIA SPECIFICA a partire dalla data di convalida da parte del Servizio di Assistenza della Sua Zona La invitiamo quindi a rivolgersi tempestivamente al suddetto I bruciatori sono...

Page 5: ...da un centro di assi stenza autorizzato dalla casa costruttrice utilizzando esclusivamente ricambi originali Il mancato rispetto di quanto sopra pu compromettere la sicurezza dell apparecchio Per gar...

Page 6: ...predispo sto come indicato sulla targhetta con i dati caratteristici e nelle caratteristiche tecniche fornite in questo manuale Inoltre dovr essere dotato di tutti i meccanismi di controllo e sicurez...

Page 7: ...regolamentazioni vigenti in materia di elettricit Dopo aver tolto tutti i materiali dall imballo controllare i contenuti ed assicurarsi che questi non siano stati in alcun modo danneggiati durante il...

Page 8: ...5 80 85 135 160 M8 170 144 CURVE DI LAVORO Le curve rappresentate in diagramma sono state ottenute effettuando le prove di combustio ne secondo le specifiche e le caratteristiche di focolare previste...

Page 9: ...3 6 3 6 3 F Trasformatore di accensione tensione corrente secondario 15 40 15 40 15 40 15 40 kV mA Grado di protezione elettrica 20 20 20 20 IP Rumorosit 61 61 61 61 dB A Peso 10 10 1 10 10 1 kg Press...

Page 10: ...mpada di blocco e o contaore ATTENZIONE non scambiare il neutro con la fase eseguire un buon collegamento di terra FOCUS PRO 3 FOCUS PRO 6 Legenda CO Contaore F Fusibile FA Filtro antidisturbo FR Foto...

Page 11: ...Contaore F Fusibile FA Filtro antidisturbo FR Fotoresistenza IG Interruttore generale LS Lampada di sicurezza MA Morsettiera apparecchiatura MB Motore bruciatore PB Presa bruciatore PR Preriscaldator...

Page 12: ...5 3 90 32 62 34 63 36 76 38 78 40 92 42 69 44 47 46 25 1 00 3 10 3 30 3 50 3 67 3 85 4 02 4 20 4 38 36 76 39 13 41 51 43 52 45 66 47 67 48 72 51 95 1 25 3 85 4 12 4 40 4 61 4 82 5 03 5 25 5 46 45 66 4...

Page 13: ...nsione il bruciatore si mette in funzione e resta acceso fino a che non si raggiunta la temperatura prestabilita sull apparecchiatura di comando che inter verr per prima termostato caldaia termostato...

Page 14: ...ressione 5 Attacco manometro 1 8 6 Attacco vacuometro 1 8 ITALPUMP DANFOSS 4 5 5 6 6 3 3 3 2 2 1 4 REGOLAZIONE SERRANDA ARIA Dopo aver allentato la vite 3 agendo sulla vite 1 si ottiene la regolazione...

Page 15: ...ulsante di sblocco dell apparecchiatura l elemento principale per poter accedere a tutte le funzioni di diagnostica attivazione e disattivazione oltre a sbloccare il dispositivo di co mando e controll...

Page 16: ...atura del bruciatore assenza di combustibile 8 lampeggi Anomalia del tempo preriscaldamento de combustibile 9 lampeggi Libero 10 lampeggi Errori di collegamento elettrico o danni all apparecchiatura M...

Page 17: ...i sufficiente svitare la vite 1 e togliere il cofano Per accedere alla ventola svitare le 4 viti 2 del semicorpo aria del bruciatore Togliendo il coperchio aspirazione aria 3 tramite le 3 viti 4 si ac...

Page 18: ...ogliere il deflettore e la vite 6 per togliere gli elettrodi Una buona pulizia dell ugello si ottiene smontando il filtro e pulendo i tagli ed il foro di polverizzazione con ben zina e risciacquarlo c...

Page 19: ...che chiuse lungo la linea gasolio Il bruciatore si avvia Si ha formazione della fiamma e poi si arresta in blocco 1 Fotoresistenza sporca 1 Pulire la fotoresistenza 2 Ugello che polverizza male 2 Puli...

Page 20: ...ied service and maintenance of the boiler CONFORMITY INDEX The burners are in conformity with 2006 42 EC Machinery Directive 2014 30 EU Electromagnetic Compatibility EMC 2014 35 EU Low Voltage Directi...

Page 21: ...order to guarantee the efficiency of the appliance and its correct functioning it is indispen sable to follow the manufacturer s indications Have qualified professional staff perform periodic maintena...

Page 22: ...earth plant in compliance with Standards in force The earth cable must be a couple of cm longer that the phase and neutral wire If in doubt regarding efficiency it must be checked and controlled by q...

Page 23: ...2 1 4 1 6 mbar 20 40 60 80 100 120 140 160 PA 10 0 0 1 0 Focus Pro 6 Focus Pro 6R Focus Pro 3 Focus Pro 3R Output Combustion chamber pressure Model A B C D E F G H I L M min max FOCUS PRO 3 280 305 2...

Page 24: ...F Trasformator voltage secondary current 15 40 15 40 15 40 15 40 kV mA Electric protection rating 20 20 20 20 IP Noise level 61 61 61 61 dB A Peso 10 10 1 10 10 1 kg Sound pressure measured in the man...

Page 25: ...onnection VE FR LS N PB SC TC TA B4 T2 T1 L1 S3 N CO H Z N N L IG F TS M MB FA TR 1 2 2 2 3 4 5 6 7 8 9 10 11 12 MA FOCUS PRO 3 FOCUS PRO 6 Key CO Hour meter F Fuse FA Anti interference filter FR Phot...

Page 26: ...S PRO 3R FOCUS PRO 6R Key CO Hour meter F Fuse FA Anti interference filter FR Photoresistance IG Main switch LS Safety lamp MA Control box MB Burner motor PB Burner connector PR Preheater SC Plug TA T...

Page 27: ...5 65 82 68 78 71 75 74 72 77 68 1 75 5 40 5 69 6 18 6 46 6 75 7 06 7 38 7 96 64 04 67 48 73 29 76 61 80 05 83 73 87 53 91 20 2 00 6 20 6 63 7 07 7 43 7 75 8 10 8 42 8 80 73 53 78 63 83 85 88 12 91 92...

Page 28: ...tch to ON After the pre ignition time has elapsed the burner starts running and stays on until the temperature set on one of the control devices causes the latter to trip boiler thermostat room thermo...

Page 29: ...4 Pressure adjustment 5 Pressure gauge port 1 8 6 Vacuum gauge port 1 8 ITALPUMP DANFOSS 4 5 5 6 6 3 3 3 2 2 1 1 4 AIR FLAP ADJUSTMENT After having untightened the screw 3 whith the screw 1 it obtain...

Page 30: ...espect of the environment The release pushbutton on the equipment is the main component for accessing all the dia gnostic functions activation and deactivation as well as for releasing the control and...

Page 31: ...no fuel 8 flashes Anomalies in fuel preheating time 9 flashes Not used 10 flashes Incorrect electrical connection or damage to equipment MAINTENANCE WARNING All operations should be performed with the...

Page 32: ...onents simply unscrew the screw 1 and remove the cover To access the fan unscrew the 4 screws 2 of the semi body air burner By removing the air intake cover 3 through the 3 screws 4 you can access the...

Page 33: ...eplacement or assembly disassembly of the fan make sure that the latter does not touch the body burner platform as illustrated in the inclosed diagram 3 2 4 1 4 Remove a screw 5 in order to remove the...

Page 34: ...line The burner starts There is the formation of the flame and then stops in block 1 Photoresistance is dirty 1 Clean the photoresistance 2 Nozzle is pulverizing badly 2 Clean or replace nozzle Flame...

Page 35: ...de l entretien et de la maintenance de nos appareils CONFORMIT INDEX Les br leurs sont conformes Directive Machines 2006 42 CE Directive Compatibilit Electromagn tique 2014 30 UE Directive Basse Tens...

Page 36: ...nnellement qualifi La r paration ven tuelle des produits ne devra tre effectu e que par un Service apr s vente agr par le fabricant en utilisant exclusivement des pi ces d tach es d origine Le non res...

Page 37: ...ustion La poussi re est extr mement nuisible en particulier lorsqu elle se d pose sur les pales du ventilateur r duisant la ventilation et don nant lieu une combustion polluante La poussi re peut gale...

Page 38: ...t de la porte de la chaudi re Les connexions lectriques doivent tre r alis es exclusivement par un personnel qualifi et doivent tre conformes aux r glementations en vigueur en mati re d lectricit Apr...

Page 39: ...2 0 4 0 6 0 8 1 1 2 1 4 1 6 mbar 20 40 60 80 100 120 140 160 PA 10 0 0 1 0 Focus Pro 6 Focus Pro 6R Focus Pro 3 Focus Pro 3R Puissance termique Pression dans la chambre de combustion Mod le A B C D E...

Page 40: ...6 3 6 3 6 3 6 3 F Transformateur tension courant secondaire 15 40 15 40 15 40 15 40 kV mA Degr de protection lectrique 20 20 20 20 IP Bruit 61 61 61 61 dB A Poids 10 10 1 10 10 1 kg Pression acoustiq...

Page 41: ...hermostats ventuelle t moin de blocage et ou compte heures ATTENTION ne pas changer le neutre avec la phase r aliser un bon branchement de terre L gende CO Compte heures F Fusible FA Filtre antiparasi...

Page 42: ...mpte heures F Fusible FA Filtre antiparasite FR Photor sistance IG Int rrupteur g n ral LS T moin de s curit MA Bornier du coffret de s curit MB Moteur brule r PB Prise brule r PR Pr chauffeur SC Fich...

Page 43: ...47 46 25 1 00 3 10 3 30 3 50 3 67 3 85 4 02 4 20 4 38 36 76 39 13 41 51 43 52 45 66 47 67 48 72 51 95 1 25 3 85 4 12 4 40 4 61 4 82 5 03 5 25 5 46 45 66 48 86 52 18 54 67 57 16 59 65 62 26 64 75 1 50...

Page 44: ...n intervenant sur l interrupteur principal Apr s le temps de pr allu mage le br leurse met en marche et reste allum aussi longtemps que la temp rature pr fix e sur le coffret de s curit qui est le pre...

Page 45: ...piration 1 4 2 Retour 1 4 3 Raccord fioul domestique 1 8 4 R glage de pression 5 Raccord manom tre 1 8 6 Raccord vacuom tre 1 8 REGLAGE CLAPET D AIR Apr s avoir d ss r la vis 3 avec la vis 1 on a la r...

Page 46: ...ton de d clenchement de l appareil est l l ment principal pour pouvoir acc der toutes les fonctionsde diagnostic activation et d sactivation et pour pouvoir d bloquer le dispositif de commande et de c...

Page 47: ...ur de flamme D fectuosit au niveau du r glage du br leur absencede combustible 8 clignotements Irr gularit du temps de pr chauffage du combustible 9 clignotements Libre 10 clignotements Erreurs au niv...

Page 48: ...suffit de d visser la vis 1 et d enlever le capot Pour acc der au ventilateur d vissez les 4 vis 2 du demi corps d air du br leur En enlevant le couvercle d entr e d air 3 travers les 3 vis 4 on acc d...

Page 49: ...s de remplacement ou de d montage montagedu rotor de ventilation contr ler que ce dernier ne touche pas le plan du corps du br leur en respectant les indica tions ci jointes Devisser la vis 5 pour enl...

Page 50: ...de la ligne fioul Le br leur s allume La flame seforme puis il s arr te en s curit 1 Photor sistance sale 1 Nettoyer la photor sistance 2 Le gicleur qui pulv rise mal 2 Nettoyer ou substituer le gicl...

Page 51: ...INYECTOR 59 INSTALACI N 60 REGULACIONES 60 CONTROL COMBUSTION 62 EQUIPO LMO 62 MANTENIMIENTO 63 BUSQUEDA FALLOS 66 Le damos las gracias por haber preferido uno de nuestros productos LAMBORGHINI CALORE...

Page 52: ...bstenerse de realizar cualquier reparaci n u operaci n directa sobre el mismo Ponerse en contacto solamente con personal cualificado Las reparaciones deben ser efectuadas solamente por un centro de as...

Page 53: ...ti n El polvo tambi n se puede acumular en la parte posterior del disco de estabilidad de la llama en la cabeza de combusti n y provocar una mezcla de aire escaso combustible El quemador debe alimenta...

Page 54: ...caldera Las conexiones el ctricas solamente deben ser efectuadas por personal cualificado respe tando totalmente las disposiciones en vigor Despu s de quitar el material de embalaje controlar el conte...

Page 55: ...2 0 4 0 6 0 8 1 1 2 1 4 1 6 mbar 20 40 60 80 100 120 140 160 PA 10 0 0 1 0 Focus Pro 6 Focus Pro 6R Focus Pro 3 Focus Pro 3R Potencia t rmica Presi n en c mara de combusti n Tipo A B C D E F G H I L M...

Page 56: ...ondensador 6 3 6 3 6 3 6 3 F Transformador tensi n corriente secondario 15 40 15 40 15 40 15 40 kV mA Grado de protecci n el ctrica 20 20 20 20 IP Ruido 61 61 61 61 dB A Peso 10 10 1 10 10 1 kg Presi...

Page 57: ...ierra VE FR LS N PB SC TC TA B4 T2 T1 L1 S3 N CO H Z N N L IG F TS M MB FA TR 1 2 2 2 3 4 5 6 7 8 9 10 11 12 MA FOCUS PRO 3 FOCUS PRO 6 Descripci n CO Cuentahoras F Fusible FA Filtro antiinterferencia...

Page 58: ...Cuentahoras F Fusible FA Filtro antiinterferencia FR Fotorresistencia IG Interruptor general LS Lampara seguridad MA Regleta de borners programador MB Motor quemador PB Conector quemador PR Precalent...

Page 59: ...3 75 3 90 32 62 34 63 36 76 38 78 40 92 42 69 44 47 46 25 1 00 3 10 3 30 3 50 3 67 3 85 4 02 4 20 4 38 36 76 39 13 41 51 43 52 45 66 47 67 48 72 51 95 1 25 3 85 4 12 4 40 4 61 4 82 5 03 5 25 5 46 45...

Page 60: ...sa PUESTA EN FUNCIONAMIENTO Efect e el rearme mediante el bot n Encienda el interruptor general Tras el tiempo de preencendido el quemador se pone en funcionamientoy se queda encendido hasta que no se...

Page 61: ...ida gasoleo 1 8 4 Regulaci n presi n 5 Conexi n de man metro 1 8 6 Conexi n del vacu metro 1 8 REGULACION CLAPETA AIRE Despues de haber aflojado el tornillo 3 interviniendo en el tornillo 1 se obtiene...

Page 62: ...El pulsador de desbloqueo del equipo es el elemento principal para poder acceder a todas las funciones deldiagn stico activaci n y desactivaci n adem s de desbloquear el disposi tivo de mando y contr...

Page 63: ...el quemador falta combu stible 8 destellos Anomal a del tiempo de precalentamiento del combustible 9 destellos Libre 10 destellos Errores en la conexi n el ctrica o equipo da ado MANTENIMIENTO ATENCI...

Page 64: ...sque el tornillo 1 y retire la tapa Para acceder al ventilador desatornille los 4 tornillos 2 del medio cuerpo del aire del quemador Al retirar la tapa de entrada de aire 3 a trav s de los 3 tornillos...

Page 65: ...ATTENTION En cas de remplacement ou de d montage montagedu rotor de ventilation contr ler que ce dernier ne touche pas le plan du cuerpo del quemador en respectant les indications ci jointes Quitar e...

Page 66: ...lo largo de la l nea gasoleo El quemador se accio na Se forma la llama y luego se detiene en bloque 1 Fotorresistencia sucia 1 Limpiar la fotorresistencia 2 Inyector pulveriza mal 2 Limpiar o reempla...

Page 67: ......

Page 68: ...es modifications qu elle retient le plus necessai res pour l evolution du produit Las ilustraciones y los datos son indicativos y no comprometen Lamborghini Caloreclima se reserva el derecho de realiz...

Reviews: