- 24
-
INSTALLATION
INSTALLATION WHEN REPLACING ANOTHER APPARATUS
When solar boilers
Series BDS
are installed on systems being
old or to be renewed, make sure that
- Safety and control tools are available during installation, in
compliance with the relevant standards in force.
- The system is perfectly clean, free of muds and scales,
deaerated and that water seals are in good conditions.
- A proper treatment system is provided in the presence of
special feeding/reinstatement water. Please refer to the
values reported in the table beside here.
WATER CONNECTIONS
Solar boilers
Series BDS
can be connected to existing air
heaters, provided their thermal power is compatible and water
flow direction is maintained. They are especially suitable for
installation solar systems.
Water connections features:
FEEDING WATER VALUES
pH
6-8
Electric conductivity
less than 200 mV/cm (25°C)
Chlorine ions
less than 50 ppm
Ioni acido solforico
less than 50 ppm
Overall iron
less than 0,3 ppm
Alkalinity M
less than 50 ppm
Overall hardness
less than 35°F
Sulphur ions
none
Ammonia ions
none
Silicon ions
less than 30 ppm
Description
BDS 200
BDS 300
BDS 500
BDS 750
BDS 1000
C
- Hot water outlet
1" 1/4
1" 1/4
1" 1/4
1" 1/4
1" 1/4
Ø mm
SC
- Boiler probe
1/2"
1/2"
1/2"
1/2"
1/2"
Ø mm
RC - Hot water tank recirculation
1" 1/4
1" 1/4
1" 1/4
1" 1/4
1" 1/4
Ø mm
SS
- Solar probe
1/2"
1/2"
1/2"
1/2"
1/2"
Ø mm
F
- Cold water inlet
1" 1/4
1" 1/4
1" 1/4
1" 1/4
1" 1/4
Ø mm
S
- Discharge
1" 1/4
1" 1/4
1" 1/4
1" 1/4
1" 1/4
Ø mm
1
- Upper coil inlet
1"
1"
1"
1" 1/4
1" 1/4
Ø mm
2
- Upper coil outlet
1"
1"
1"
1" 1/4
1" 1/4
Ø mm
3
- Lower coil inlet
1"
1"
1"
1" 1/4
1" 1/4
Ø mm
4
- Lower coil outlet
1"
1"
1"
1" 1/4
1" 1/4
Ø mm
5
- Flange
180
180
180
180
180
Ø mm
A
1140
1150
1415
1450
1700
mm
B
980
1015
1235
1250
1450
mm
D
770
935
1065
1080
1200
mm
E
300
295
355
390
390
mm
G
290
275
335
360
360
mm
I
970
935
1175
1200
1425
mm